Thermal performance of two evacuated tube solar collectors with flat heat pipes

被引:6
|
作者
Zhang, Dengke [1 ]
Diao, Yanhua [1 ]
Wang, Zeyu [2 ]
Pan, Yawen [1 ]
Sun, Mengda [1 ]
Wang, Xinran [1 ]
Du, Peiyuan [1 ]
Zhao, Yaohua [1 ,3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
[2] China Nucl Power Engn Co Ltd, Beijing 100089, Peoples R China
[3] Zibo Boienergy Sci & Technol Co Ltd, Shandong 255000, Peoples R China
关键词
Flat micro-heat pipe array; Multi-channel flat tube; Louver fin; Solar water collector; Evacuated tube collector; AIR HEATER; PLATE; SYSTEMS; DESIGN;
D O I
10.1016/j.applthermaleng.2024.122366
中图分类号
O414.1 [热力学];
学科分类号
摘要
To promote the transition to clean heating methods in rural areas and improve solar energy utilization efficiency, two new types of solar water collectors with evacuated tubes, namely finned and finless collectors, are constructed with multi-channel flat tubes and flat micro-heat pipe arrays, and comparison experiments are conducted. By integrating with multi-channel flat tubes, the micro-heat pipe arrays, which function as the central heat transfer component, are capable of attaining effective thermal transmission. The multi-channel flat tubes have a substantial surface area available for heat transfer with the thermal fluid, while the evacuated tubes exhibit superior thermal insulation performance. The structural discrepancy between the two collectors lies in the presence or absence of louvered fins attached to the flat heat pipes inside the evacuated tubes. The comparative analysis of the two collectors includes time constant, thermal resistance analysis, distribution of temperature, normalized temperature difference, pressure drop, and actual operation effect under different conditions. The average thermal efficiency of the finless collector (59.4 %) is lower than that of the finned collector (78.2 %) on a typical experimental day. Then, further investigations are conducted to explore the effects of heat transfer fluid volume flow rate and inlet temperature on the thermal performance of finned solar water collector. With the heat transfer fluid volume flow rate of 120 L/h and the inlet temperature at 15 C, the finned collector can achieve its maximum thermal efficiency of 86.4 %.
引用
收藏
页数:25
相关论文
共 50 条
  • [41] Experimental Comparison of Flat Plate and Evacuated Tube Solar Thermal Collectors for Domestic Hot Water Preparation in Education Facilities
    Moldovan, Macedon
    Visa, Ion
    Burduhos, Bogdan Gabriel
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2020, 8 (02): : 293 - 303
  • [42] Performance analysis of a solar still coupled with evacuated heat pipes
    Pramod, B. V. N.
    Raj, Prudhvi J.
    Krishnan, Hari S. S.
    Kotebavi, Vinod
    INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2017), 2018, 310
  • [43] Development of Dynamic Thermal Modeling for Evacuated U-Tube Solar Collectors
    Toker, Serpil Celik
    Kizilkan, Onder
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [44] Energy performance enhancement of solar thermal power plants by solar parabolic trough collectors and evacuated tube collectors-based preheating units
    Alsagri, Ali Sulaiman
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (08) : 6828 - 6842
  • [45] Improving solar still performance with heat pipe/pulsating heat pipe evacuated tube solar collectors and PCM: An experimental and environmental analysis
    Hemmatian, Amir
    Kargarsharifabad, Hadi
    Esfahlani, Ahad Abedini
    Rahbar, Nader
    Shoeibi, Shahin
    SOLAR ENERGY, 2024, 269
  • [46] Evacuated tubular or classical flat plate solar collectors?
    Pluta, Zbyslaw
    JOURNAL OF POWER TECHNOLOGIES, 2011, 91 (03): : 158 - 164
  • [47] Experimental study and CFD thermal assessment of horizontal hot water storage tank integrating Evacuated Tube Collectors with heat pipes
    Ed-Din Fertahi, Saif
    Bouhal, T.
    Kousksou, T.
    Jamil, A.
    Benbassou, A.
    SOLAR ENERGY, 2018, 170 : 234 - 251
  • [48] Simulator testing of evacuated flat plate solar collectors for industrial heat and building integration
    Moss, R. W.
    Henshall, P.
    Arya, F.
    Shire, G. S. F.
    Eames, P. C.
    Hyde, T.
    SOLAR ENERGY, 2018, 164 : 109 - 118
  • [49] Performance and operational effectiveness of evacuated flat plate solar collectors compared with conventional thermal, PVT and PV panels
    Moss, R. W.
    Henshall, P.
    Arya, F.
    Shire, G. S. F.
    Hyde, T.
    Eames, P. C.
    APPLIED ENERGY, 2018, 216 : 588 - 601
  • [50] Theoretical and experimental analysis of the thermal performance of a heat-pipe evacuated solar tube
    He, ZN
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 849 - 854