Thermal performance of two evacuated tube solar collectors with flat heat pipes

被引:6
|
作者
Zhang, Dengke [1 ]
Diao, Yanhua [1 ]
Wang, Zeyu [2 ]
Pan, Yawen [1 ]
Sun, Mengda [1 ]
Wang, Xinran [1 ]
Du, Peiyuan [1 ]
Zhao, Yaohua [1 ,3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
[2] China Nucl Power Engn Co Ltd, Beijing 100089, Peoples R China
[3] Zibo Boienergy Sci & Technol Co Ltd, Shandong 255000, Peoples R China
关键词
Flat micro-heat pipe array; Multi-channel flat tube; Louver fin; Solar water collector; Evacuated tube collector; AIR HEATER; PLATE; SYSTEMS; DESIGN;
D O I
10.1016/j.applthermaleng.2024.122366
中图分类号
O414.1 [热力学];
学科分类号
摘要
To promote the transition to clean heating methods in rural areas and improve solar energy utilization efficiency, two new types of solar water collectors with evacuated tubes, namely finned and finless collectors, are constructed with multi-channel flat tubes and flat micro-heat pipe arrays, and comparison experiments are conducted. By integrating with multi-channel flat tubes, the micro-heat pipe arrays, which function as the central heat transfer component, are capable of attaining effective thermal transmission. The multi-channel flat tubes have a substantial surface area available for heat transfer with the thermal fluid, while the evacuated tubes exhibit superior thermal insulation performance. The structural discrepancy between the two collectors lies in the presence or absence of louvered fins attached to the flat heat pipes inside the evacuated tubes. The comparative analysis of the two collectors includes time constant, thermal resistance analysis, distribution of temperature, normalized temperature difference, pressure drop, and actual operation effect under different conditions. The average thermal efficiency of the finless collector (59.4 %) is lower than that of the finned collector (78.2 %) on a typical experimental day. Then, further investigations are conducted to explore the effects of heat transfer fluid volume flow rate and inlet temperature on the thermal performance of finned solar water collector. With the heat transfer fluid volume flow rate of 120 L/h and the inlet temperature at 15 C, the finned collector can achieve its maximum thermal efficiency of 86.4 %.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Performance of evacuated flat plate solar thermal collectors
    Moss, Roger
    Shire, Stan
    Henshall, Paul
    Arya, Farid
    Eames, Philip
    Hyde, Trevor
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 296 - 306
  • [2] Comparative Study on the Thermal Performance of Evacuated Solar Collectors with U-Tubes and Heat Pipes
    Tong, Yijie
    Cho, Honghyun
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (03)
  • [3] Thermal performance enhancement of flat-plate and evacuated tube solar collectors using nanofluid: A review
    Muhammad, Mahmud Jamil
    Muhammad, Isa Adamu
    Sidik, Nor Azwadi Che
    Yazid, Muhammad Noor Afiq Witri Muhammad
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 76 : 6 - 15
  • [4] EXPERIMENTAL DAILY ENERGY PERFORMANCE OF FLAT PLATE AND EVACUATED TUBE SOLAR COLLECTORS
    Zambolin, Enrico
    Del Col, Davide
    Padovan, Andrea
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 853 - 862
  • [5] Proof of guaranteed solar yields in solar thermal plants with flat plate and evacuated tube collectors
    Karandashev, Artem
    Eberhardt, Kay
    Gaspar, Paul
    Meißner, Rolf
    Euroheat and Power/Fernwarme International, 2022, 51 (7-8): : 24 - 31
  • [6] Improving the experimental estimation of the incident angle modifier of evacuated tube solar collectors with heat pipes
    Rodriguez-Munoz, J. M.
    Bove, I.
    Alonso-Suarez, R.
    RENEWABLE ENERGY, 2024, 235
  • [7] Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions
    Zambolin, E.
    Del Col, D.
    SOLAR ENERGY, 2010, 84 (08) : 1382 - 1396
  • [8] Thermal modeling of evacuated tube solar air collectors
    Paradis, Pierre-Luc
    Rousse, Daniel R.
    Halle, Stephane
    Lamarche, Louis
    Quesada, Guillermo
    SOLAR ENERGY, 2015, 115 : 708 - 721
  • [9] Performance analysis and comparison of concentrated evacuated tube heat pipe solar collectors
    Nkwetta, Dan Nchelatebe
    Smyth, Mervyn
    APPLIED ENERGY, 2012, 98 : 22 - 32
  • [10] Research on thermal performance and flow resistance of evacuated tube solar air collectors
    Zeng, D. (zengdongqi6@163.com), 1600, Science Press (35):