The Repeatability of Axial Length Measurements Using a Scheimpflug-based System

被引:0
|
作者
Sardari, Sara [1 ,2 ]
Khabazkhoob, Mehdi [3 ]
Jafarzadehpur, Ebrahim [4 ]
Fotouhi, Akbar [5 ]
机构
[1] Univ Tehran Med Sci, Tehran, Iran
[2] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Basic Sci, Tehran, Iran
[4] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran 14176, Iran
关键词
Axial Length; Signal-To-Noise Ratio; Repeatability; Scheimpflug Imaging; Partial Coherence Interferometry; ANTERIOR-CHAMBER DEPTH; INTRAOCULAR-LENS POWER; PARTIAL COHERENCE INTERFEROMETRY; TOMOGRAPHIC ANALYSIS; OPTICAL BIOMETRY; AGREEMENT; PENTACAM; DEVICES; ERROR; NOISE;
D O I
10.18502/jovr.v18i4.14551
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value, and type of cataract. Methods: The present study was conducted using multistage cluster sampling in Tehran, Iran. Ocular biometry was performed, using the Pentacam AXL, by an experienced optometrist on all the participants. The axial length (AL) measurements were taken thrice, with a gap of 10 minutes. To evaluate the repeatability, the intraclass correlation coefficient (ICC) and the repeatability coefficient (RC) were calculated. To determine the significant difference in the repeatability index among study variables, the tolerance index (TI) was calculated.Results: In this report, 897 eyes of 677 individuals aged between 20 and 91 years (mean +/- SD: 64.90 +/- 13.62 years) were reported. The ICC of the axial length measurements was 0.981 for all cases. Based on the within-subject standard deviation, the RC was 0.401. The ICC was 0.976 and 0.985 in men and women, respectively. The TI showed better RC of measurements among females. The ICC decreased from 0.999 in participants under 40 years to 0.973 in individuals over 60 years of age. The TI showed a decrease in RC with advancing age. The RC was worse in eyes with nuclear cataracts; the RC was also worse in the first quartile of the signal-to-noise ratio (SNR) compared to the other SNR quartiles.Conclusion: The Scheimpflug-based system Pentacam AXL had high repeatability in measuring axial length. Some variables such as male gender, older age, and nuclear cataract were associated with reduced repeatability of the measurements. A higher SNR was associated with better repeatability of the axial length measurements.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 50 条
  • [21] The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster™
    Lam, AKC
    Chan, R
    Pang, PCK
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (06) : 477 - 483
  • [22] Comparison of ectasia detection in early keratoconus using Scheimpflug-based corneal tomography and biomechanical assessments
    Wallace, Henry B.
    Vellara, Hans
    Gokul, Akilesh
    Meyer, Jay
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 885 - 886
  • [23] Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
    Altiparmak, Zeynep
    Yagci, Ramazan
    Guler, Emre
    Arslanyilmaz, Zeynel
    Canbal, Metin
    Hepsen, Ibrahim F.
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2015, 45 (06): : 243 - 248
  • [24] OCT- versus Scheimpflug-based Total Corneal Power Measurements Changes in Myopic Astigmatic SMILE Procedures
    Lischke, Roman
    Shajari, Mehdi
    Feucht, Nikolaus
    Kook, Daniel
    Bechmann, Martin
    Wiltfang, Rainer
    Priglinger, Siegfried G.
    Mayer, Wolfgang J.
    CURRENT EYE RESEARCH, 2022, 47 (01) : 12 - 17
  • [25] Agreement Between Swept-Source Optical Biometry and Scheimpflug-based Topography Measurements of Anterior Segment Parameters
    Ozyol, Pelin
    Ozyol, Erhan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 73 - 78
  • [26] Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes
    Ruiz-Belda, Clara
    Pinero, David P.
    Ruiz-Fortes, Pedro
    Soto-Negro, Roberto
    Moya, Myriam
    Perez-Cambrodi, Rafael J.
    Artola, Alberto
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (01) : 169 - 175
  • [27] Agreement between swept-source optical biometry and Scheimpflug-based topography measurements of posterior corneal curvature
    Kose, Bulent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 185 - 189
  • [28] Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes
    Clara Ruiz-Belda
    David P. Piñero
    Pedro Ruiz-Fortes
    Roberto Soto-Negro
    Myriam Moya
    Rafael J Pérez-Cambrodí
    Alberto Artola
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 169 - 175
  • [29] Repeatability of lens densitometry using Scheimpflug imaging
    Weiner, Xenia
    Baumeister, Martin
    Kohnen, Thomas
    Buehren, Jens
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (05): : 756 - 763
  • [30] Corneal Biomechanics in Unilateral Keratoconus and Fellow Eyes with a Scheimpflug-based Tonometer
    Catalan-Lopez, Sara
    Cadarso-Suarez, Luis
    Lopez-Raton, Monica
    Cadarso-Suarez, Carmen
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (07) : 608 - 615