摘要
Multi-line LiDAR and GPS/IMU are widely used in autonomous driving and robotics, such as simultaneous localization and mapping (SLAM). Calibrating the extrinsic parameters of each sensor is a necessary condition for multi-sensor fusion. The calibration of each sensor directly affects the accurate positioning control and perception performance of the vehicle. Through the algorithm, accurate extrinsic parameters and a symmetric covariance matrix of extrinsic parameters can be obtained as a measure of the confidence of the extrinsic parameters. As for the calibration of LiDAR-GPS/IMU, many calibration methods require specific vehicle motion or manual calibration marking scenes to ensure good constraint of the problem, resulting in high costs and a low degree of automation. To solve this problem, we propose a new two-step self-calibration method, which includes extrinsic parameter initialization and refinement. The initialization part decouples the extrinsic parameters from the rotation and translation part, first calculating the reliable initial rotation through the rotation constraints, then calculating the initial translation after obtaining a reliable initial rotation, and eliminating the accumulated drift of LiDAR odometry by loop closure to complete the map construction. In the refinement part, the LiDAR odometry is obtained through scan-to-map registration and is tightly coupled with the IMU. The constraints of the absolute pose in the map refined the extrinsic parameters. Our method is validated in the simulation and real environments, and the results show that the proposed method has high accuracy and robustness.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Grounding rod hanging and removing robot with hand-eye self-calibration capability in substation
    Lin, Yunhan
    Wang, Jiahui
    Liu, Kaibo
    Min, Huasong
    COMPLEX & INTELLIGENT SYSTEMS, 2024, 10 (05) : 6491 - 6507
  • [22] Uncontrolled Two-Step Iterative Calibration Algorithm for Lidar-IMU System
    Yin, Shilun
    Xie, Donghai
    Fu, Yibo
    Wang, Zhibo
    Zhong, Ruofei
    SENSORS, 2023, 23 (06)
  • [23] A Two-Step Self-calibration Method with Portable Measurement Devices for Industrial Robots Based on POE Formula
    Gu, Lefeng
    Yang, Guilin
    Fang, Zaojun
    Shen, Wenjun
    Zheng, Tianjiang
    Chen, Chinyin
    Zhang, Chi
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2019, PT I, 2019, 11740 : 715 - 727
  • [24] Self-calibration of eye-hand system based on geometric method with perception net
    Lee, SK
    Ro, SW
    ICRA '99: IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, PROCEEDINGS, 1999, : 1269 - 1274
  • [25] Robust Accurate LiDAR-GNSS/IMU Self-Calibration Based on Iterative Refinement
    Chang, Dengxiang
    Zhou, Yunshui
    Hu, Manjiang
    Xie, Guotao
    Ding, Rongjun
    Qin, Xiaohui
    IEEE SENSORS JOURNAL, 2023, 23 (05) : 5188 - 5199
  • [26] Two-Step LiDAR/Camera/IMU Spatial and Temporal Calibration Based on Continuous-Time Trajectory Estimation
    Li, Shengyu
    Li, Xingxing
    Chen, Shuolong
    Zhou, Yuxuan
    Wang, Shiwen
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (03) : 3182 - 3191
  • [27] Research of Online Hand-Eye Calibration Method Based on ChArUco Board
    Lin, Wenwei
    Liang, Peidong
    Luo, Guantai
    Zhao, Ziyang
    Zhang, Chentao
    SENSORS, 2022, 22 (10)
  • [28] A 2-Dimensional Branch-and-Bound Algorithm for Hand-Eye Self-Calibration of SCARA Robots
    Tao, Chengyu
    Lv, Na
    Chen, Shanben
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2021), 2021, : 11408 - 11414
  • [29] An Optimal Hand-Eye Calibration Method for Robots Based on Precision Compensation
    Tian P.
    Yang S.
    Wu Z.
    Li Z.
    Hu P.
    Qu X.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2020, 54 (08): : 99 - 106
  • [30] Robot Hand-Eye Calibration Method Based on Intermediate Measurement System
    Zhang, Qi
    Tian, Wei
    Hu, Junshan
    Li, Pengcheng
    Wu, Chao
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2021, PT III, 2021, 13015 : 37 - 47