Minifragment plating of the fibula in unstable ankle fractures

被引:5
|
作者
Penning, D. [1 ]
Jonker, C. A. L. [1 ]
Buijsman, R. [2 ]
Halm, J. A. [1 ]
Schepers, T. [1 ]
机构
[1] Amsterdam UMC, Locat AMC, Trauma Unit, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[2] Tergooi MC, Dept Traumasurg, Van Riebeeckweg 212, NL-1213 XZ Hilversum, Netherlands
关键词
Distal fibula fracture; Minifragment; Small fragment; Ankle fracture; Fibula; IMPLANT REMOVAL; FIXATION; EPIDEMIOLOGY; SCREW;
D O I
10.1007/s00402-022-04397-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Only 6.4-17% of the load is transmitted through the fibula when weight-bearing. Plate fixation of distal fibular fractures using minifragments (<= 2.8 mm) could lead to similar reduction with less implant removal (IR) rates, compared to small-fragment plates (3.5 mm). We hypothesized that the use of minifragment plates is at least similar in unscheduled secondary surgery. Materials and methods In this retrospective cohort study, all patients with surgically treated distal fibular fractures between October 2015 and March 2021 were included. Patients treated with plate fixation using minifragments and patients treated with small-fragment plates were compared regarding the following outcomes: secondary dislocation, malreduction, implant malposition, nonunion, surgical site infections (SSI) and IR. Results Sixty-five patients (54.2%) received a minifragment implant (<= 2.8 mm) and 55 patients (45.8%) received a small-fragment implant (3.5 mm). There were no patients needing secondary surgery in the minifragment group compared to 9 patients following fixation using small-fragment implants (3 with secondary dislocation, 5 with malreduction and 1 with malposition, p = 0.001). SSI rates were 3.1% for minifragment and 9.1% for small-fragment implants (p = 0.161). Implant removal was performed significantly less often following use of minifragment implants (17.8% and 53.2%, p < 0.001). Conclusions In this cohort, minifragment plate fixation for distal fibular fractures is an adequate fixation method offering stable fixation with significant lower need for implant removal and comparable complications to small-fragment plates, although an adequately powered randomized controlled study is needed for implementation in a clinical setting.
引用
收藏
页码:1499 / 1504
页数:6
相关论文
共 50 条
  • [21] THE TREATMENT OF UNSTABLE FRACTURES OF THE ANKLE IN THE ELDERLY
    LITCHFIELD, JC
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1987, 18 (02): : 128 - 132
  • [22] Fractures of the ankle joint and of the lower end of the tibia and fibula
    Gilcreest, EL
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1927, 88 : 0223 - 0226
  • [23] Biologic plating of unstable distal radial fractures
    Jae-Man Kwak
    Gu-Hee Jung
    BMC Musculoskeletal Disorders, 19
  • [24] Biologic plating of unstable distal radial fractures
    Kwak, Jae-Man
    Jung, Gu-Hee
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [25] Outcomes Following Posterior and Posterolateral Plating of Distal Fibula Fractures
    Vance, Danica D.
    Swindell, Hasani W.
    Greisberg, Justin K.
    Vosseller, James T.
    FOOT & ANKLE SPECIALIST, 2019, 12 (03) : 246 - 252
  • [26] TREATMENT OF UNSTABLE OSTEOPOROTIC BIMALLEOLAR ANKLE FRACTURES
    Teoh, K. H.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 : S79 - S79
  • [27] CORRECTIVE OSTEOTOMIES OF FIBULA AFTER DEFECTIVELY HEALED ANKLE FRACTURES
    HUGHES, JL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (05): : 728 - 728
  • [28] Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis
    Ebraheim, NA
    Mekhail, AO
    Gargasz, SS
    FOOT & ANKLE INTERNATIONAL, 1997, 18 (08) : 513 - 521
  • [29] Functional Outcomes of Unstable Ankle Fractures in Adolescents
    Lurie, Benjamin M.
    Bomar, James D.
    Edmonds, Eric W.
    Pennock, Andrew T.
    Upasani, Vidyadhar V.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2020, 40 (07) : E572 - E578
  • [30] Management of unstable ankle fractures with Kirschner wires
    Oosterhuis, JWA
    Houben, P
    TROPICAL DOCTOR, 1997, 27 (04) : 230 - 231