Monitoring groundwater quality with real-time data, stable water isotopes, and microbial community analysis: A comparison with conventional methods

被引:18
|
作者
Lyons, Kevin J. [1 ]
Ikonen, Jenni [2 ]
Hokajarvi, Anna-Maria [2 ]
Rasanen, Teemu [2 ,3 ,4 ]
Pitkanen, Tarja [2 ,4 ,5 ]
Kauppinen, Ari [2 ,6 ]
Kujala, Katharina [1 ]
Rossi, Pekka M. [1 ]
Miettinen, Ilkka T. [2 ]
机构
[1] Univ Oulu, Water Energy & Environm Engn Res Unit, Oulu, Finland
[2] Finnish Inst Hlth & Welf, Expert Microbiol Unit, Kuopio, Finland
[3] Preventos Informat Oy, Kuopio, Finland
[4] Savon Univ Appl Sci, Dept Environm Technol, Kuopio, Finland
[5] Univ Helsinki, Fac Vet Med, Dept Food Hyg & Environm Hlth, Helsinki, Finland
[6] Finnish Food Author, Anim Hlth Diagnost Unit, Lab & Res Div, Helsinki, Finland
关键词
Water supply; Water quality; Potable water; Drinking water; Health risks; Microbiology; DRINKING-WATER; GENETIC-MARKERS; PCR ASSAY; BACTERIA; CONTAMINATION; PATHOGENS; FINLAND; GIARDIA; QPCR;
D O I
10.1016/j.scitotenv.2022.161199
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Groundwater provides much of the world's potable water. Nevertheless, groundwater quality monitoring programmes often rely on a sporadic, slow, and narrowly focused combination of periodic manual sampling and laboratory analyses, such that some water quality deficiencies go undetected, or are detected too late to prevent adverse consequences. In an effort to address this shortcoming, we conducted enhanced monitoring of untreated groundwater quality over 12 months (February 2019-February 2020) in four shallow wells supplying potable water in Finland. We supplemented periodic manual sampling and laboratory analyses with (i) real-time online monitoring of physicochemical and hydrological parameters, (ii) analysis of stable water isotopes from groundwater and nearby surface waters, and (iii) microbial community analysis of groundwater via amplicon sequencing of the 16S rRNA gene and 16S rRNA. We also developed an early warning system (EWS) for detecting water quality anomalies by automating real-time online monitoring data collection, transfer, and analysis - using electrical conductivity (EC) and turbidity as indirect water quality indicators. Real-time online monitoring measurements were largely in fair agreement with periodic manual measurements, demonstrating their usefulness for monitoring water quality; and the findings of conventional monitoring, stable water isotopes, and microbial community analysis revealed indications of surface water intrusion and faecal contamination at some of the studied sites. With further advances in technology and affordability expected into the future, the supplementary methods used here could be more widely implemented to enhance groundwater quality monitoring - by contributing new insights and/or corroborating the findings of conventional analyses.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Real-time Ocean Water Quality Monitoring for the South Shore of Oahu
    Pawlak, G.
    McManus, M.
    Tuthill, L.
    Sevadjian, J.
    Ericksen, M.
    Rocheleau, A.
    OCEANS 2011, 2011,
  • [42] Real-Time Water Quality Monitoring System using Internet of Things
    Das, Brinda
    Jain, P. C.
    2017 INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATIONS AND ELECTRONICS (COMPTELIX), 2017, : 78 - 82
  • [43] Real-Time Water Quality Monitoring System with Predictor for Tilapia Pond
    La Madrid, Jake D.
    Dela Cruz, Jennifer C.
    Balisi, Vince Lloyd Q.
    2018 IEEE 10TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT AND MANAGEMENT (HNICEM), 2018,
  • [44] Experiences and recommendations in deploying a real-time, water quality monitoring system
    O'Flynn, B.
    Regan, F.
    Lawlor, A.
    Wallace, J.
    Torres, J.
    O'Mathuna, C.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (12)
  • [45] The Long-Term Outlook for Real-Time Water Quality Monitoring
    Umberg, Matt
    Bacon, Rick
    Rajasekharan, Vishnu
    JOURNAL AWWA, 2023, 115 (06): : 79 - 82
  • [46] Real-Time Water Quality Monitoring at a Great Lakes National Park
    Byappanahalli, Muruleedhara N.
    Nevers, Meredith B.
    Shively, Dawn A.
    Spoljaric, Ashley
    Otto, Christopher
    JOURNAL OF ENVIRONMENTAL QUALITY, 2018, 47 (05) : 1086 - 1093
  • [47] Adopting the Quality Dashboard in Pathology: Real-Time Data Monitoring and Improvement
    Chen, Yigu
    McCormack, Gina
    Heher, Yael K.
    MODERN PATHOLOGY, 2016, 29 : 492A - 492A
  • [48] Evaluation and Real-Time Monitoring of Data Quality in Electrical Impedance Tomography
    Mamatjan, Yasin
    Grychtol, Bartlomiej
    Gaggero, Pascal
    Justiz, Joern
    Koch, Volker M.
    Adler, Andy
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 1997 - 2005
  • [49] Adopting the Quality Dashboard in Pathology: Real-Time Data Monitoring and Improvement
    Chen, Yigu
    McCormack, Gina
    Heher, Yael K.
    LABORATORY INVESTIGATION, 2016, 96 : 492A - 492A
  • [50] Water Quality Real-Time Monitoring System via Biological Detection Based on Video Analysis
    Xin, Chen
    Fei, Yuan
    LIDAR IMAGING DETECTION AND TARGET RECOGNITION 2017, 2017, 10605