Harmonic Excitation Response of Standard Ultrasonic Horn Designs for Machining Nomex Honeycomb Core Composite

被引:2
|
作者
Mughal, Khurram Hameed [1 ,2 ]
Qureshi, Muhammad Asif Mahmood [1 ]
Hayat, Nasir [1 ]
Tahir, Zia ul Rehman [1 ]
Ahmad, Shahzad [3 ]
Maqbool, Adnan [4 ]
Raza, Syed Farhan [5 ]
Qaiser, Asif Ali [6 ]
Khalid, Fazal Ahmad [7 ]
Zhang, Jianfu [8 ]
机构
[1] Univ Engn & Technol, Mech Engn Dept, Lahore 54890, Pakistan
[2] Univ Lahore, Fac Engn & Technol, Dept Mech Engn, Lahore 54000, Pakistan
[3] Muhammad Nawaz Sharif Univ Engn & Technol, MNSUET, Mech Engn Dept, Multan 60000, Pakistan
[4] Univ Engn & Technol, Met & Mat Engn Dept, Lahore 54890, Pakistan
[5] Univ Engn & Technol, Ind & Mfg Engn Dept, Lahore 54890, Pakistan
[6] Univ Engn & Technol, Polymer & Proc Engn Dept, Lahore 54890, Pakistan
[7] GIK Inst Engn Sci & Technol, Fac Mat & Chem Engn, Topi, Pakistan
[8] Tsinghua Univ, State Key Lab Tribol, Dept Mech Engn, Beijing Key Lab Precis Ultraprecis Mfg Equipment, Beijing 100084, Peoples R China
来源
JURNAL KEJURUTERAAN | 2024年 / 36卷 / 01期
关键词
Finite Element Analysis (FEA); Nomex Honeycomb Composite (NHC); stresses; Standard Ultrasonic Horn (SUH); Vibration Amplitude at Tool End (VATE); PERFORMANCE; SONOTRODE;
D O I
10.17576/jkukm-2024-36(1)-06
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ultrasonic horn plays a vital role in achieving vibration amplitude at tool end (VATE) by enhancing output displacement of piezoelectric ultrasonic transducer suitable for efficient machining of advanced composites. Higher vibration amplitude enhances ultrasonic machining quality, surface integrity and dimensional accuracy of Nomex honeycomb composite (NHC) while reducing cutting forces. Furthermore, low stress concentrations allow ultrasonic tool to have more safety factor and longevity. Ultrasonic horn is designed to enhance displacement amplitude of piezoelectric ultrasonic transducer and get optimum VATE while keeping stresses in acceptable limits to avoid failure at very high operating frequency of ultrasonic machining system. In this research, variety of standard ultrasonic horns (SUH) were designed with same length and end diameters; and were tested under similar operating conditions, using finite element method. The ultrasonic actuation of the horn exploits the first axial mode of horn vibration. Harmonic response analysis was carried out to determine axial modal frequencies (AMF), VATE, stresses, and factor of safety for performance evaluation. VATE attained by step horn was found to be greatest among all other SUHs for frequency ratio greater than one, but may be prone to early failure due to high stress concentrations. VATE achieved by third order Bezier, Gaussian, exponential, catenoidal, conical and second order Bezier horns were found less than that of step horn by 11.7 %, 16.6 %, 16.7 %, 17 %, 16.73 % and 18 % respectively. However, 44.2 %, 43.43 %, 42.5 %, 43.5 %, 42.8 % and 37.67 % reduction of stresses was achieved by Gaussian, exponential, catenoidal, conical, second and third order Bezier horns respectively. Outcomes of present work would be beneficial for designers, researchers, scientists, and manufacturers of ultrasonic machine tool to select appropriate SUH designs according to requirements.
引用
收藏
页码:49 / 62
页数:14
相关论文
共 50 条
  • [31] Experimental study on rotary ultrasonic machining (RUM) characteristics of Nomex honeycomb composites (NHCs) by circular knife cutting tools
    Ahmad, Shahzad
    Zhang, Jianfu
    Feng, Pingfa
    Yu, Dingwen
    Wu, Zhijun
    JOURNAL OF MANUFACTURING PROCESSES, 2020, 58 (58) : 524 - 535
  • [32] Research on Design and FE Simulations of Novel Ultrasonic Circular Saw Blade (UCSB) Cutting Tools for Rotary Ultrasonic Machining of Nomex Honeycomb Composites
    Ahmad, Shahzad
    Zhang, Jianfu
    Feng, Pingfa
    Yu, Dingwen
    Wu, Zhijun
    Ke, Ma
    PROCEEDINGS OF 2019 16TH INTERNATIONAL BHURBAN CONFERENCE ON APPLIED SCIENCES AND TECHNOLOGY (IBCAST), 2019, : 113 - 119
  • [33] Numerical Modeling and Optimization of Nomex Honeycomb Core Milling: Influence of Longitudinal and Longitudinal-Torsional Ultrasonic Vibrations
    Zarrouk, Tarik
    Nouari, Mohammed
    Bouali, Hicham
    MACHINES, 2025, 13 (02)
  • [34] The impact response of a Nomex® honeycomb core/E-glass/epoxy composite sandwich structure to increasing velocities: Experimental and numerical analysis
    Celik, Muhammet
    Guden, Mustafa
    Sarikaya, Mustafa
    Tasdemirci, Alper
    Genc, Cem
    Ersoy, Kurtulus
    Serin, Ozgur
    COMPOSITE STRUCTURES, 2023, 320
  • [35] Thermal characteristics of multilayer sandwich Nomex honeycomb core composite with heating elements for railways wall panels
    Kadhafi, Muammar
    Park, Juyeop
    Kang, Donghoon
    Koo, Bonyong
    ADVANCED COMPOSITE MATERIALS, 2024, 33 (05) : 984 - 1002
  • [36] Dynamic Performance Evaluation of Ultrasonic Composite Horn for Machining Soft and Brittle Composites
    Mughal, Khurram Hameed
    Qureshi, Muhammad Asif Mahmood
    Hayat, Nasir
    Tahir, Zia ul Rehman
    Khalid, Fazal Ahmad
    Qaiser, Asif Ali
    Zhang, Jianfu
    JURNAL KEJURUTERAAN, 2023, 35 (01): : 169 - 178
  • [37] Misalignment Assembly Effect on the Impact Mechanical Response of Tandem Nomex Honeycomb-Core Sandwich Structures
    Yin, Yufan
    Zhang, Xiaojing
    MATERIALS, 2024, 17 (16)
  • [38] A 3D FE modeling of machining process of Nomex® honeycomb core: influence of the cell structure behaviour and specific tool geometry
    Jaafar, M.
    Atlati, S.
    Makich, H.
    Nouari, M.
    Moufki, A.
    Julliere, B.
    16TH CIRP CONFERENCE ON MODELLING OF MACHINING OPERATIONS (16TH CIRP CMMO), 2017, 58 : 505 - 510
  • [39] Rapid inspection of composite skin-honeycomb core structures with ultrasonic guided waves
    Hay, TR
    Wei, L
    Rose, JL
    Hayashi, T
    JOURNAL OF COMPOSITE MATERIALS, 2003, 37 (10) : 929 - 939
  • [40] The Response of Honeycomb Core Sandwich Panels, with Aluminum and Composite Face Sheets, to Blast Loading
    Langdon, G. S.
    Nurick, G. N.
    Yahya, M. Yazid
    Cantwell, W. J.
    JOURNAL OF SANDWICH STRUCTURES & MATERIALS, 2010, 12 (06) : 733 - 754