Pruned lightweight neural networks for arrhythmia classification with clinical 12-Lead ECGs

被引:4
|
作者
Liu, Yunqing [1 ,2 ]
Liu, Jinlei [1 ,2 ]
Tian, Yuanyuan [1 ,2 ]
Jin, Yanrui [1 ,2 ]
Li, Zhiyuan [1 ,2 ]
Zhao, Liqun [3 ]
Liu, Chengliang [1 ,2 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, AI Inst, Key Lab Artificial Intelligence, MoE, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Cardiol, Shanghai Peoples Hosp 1, 100 Haining Rd, Shanghai 200080, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Mech Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
关键词
12-lead clinical ECGs; Arrythmia classification; Network pruning; Lightweight network; ELECTROCARDIOGRAMS; DIAGNOSIS; PCA; ICA;
D O I
10.1016/j.asoc.2024.111340
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Real-time electrocardiogram (ECG) monitoring through portable or wearable devices is critical for detecting lethal arrhythmias. Despite the accuracy of 12-lead ECGs in clinical image analysis, their integration into portable devices poses challenges. This paper introduces a novel method for nonmalignant arrhythmia classification, optimized for wearable and portable devices. We utilize ECG records from Shanghai First People's Hospital, proposing a lightweight neural network strategy involving benchmark network selection, model pruning, and learning rate decay-based finetuning. The proposed Random Horizontal Flip (RHF)-based classification method demonstrated superior performance, achieving a 94.8 % accuracy on a 12-lead clinical ECG test dataset. Utilizing the modified pruning method, the classification accuracy for five-class ECGs improved by 7.2 % over the benchmark network. The model size was reduced by 51.26 %, with parameters and FLOPs decreasing by 47.6 % and 49.1 %, respectively, compared to the benchmark, all under identical hardware conditions. Further experiments were conducted on the Hold-out Test Set (HTS), designed to include ECGs that present slight variations to the original conditions, yielding a slightly lower accuracy of 92.4 %, reflecting the dataset's complexity and clinical variability. Moreover, benchmarking tests using the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database validated the method's effectiveness, achieving a 99.24 % accuracy and maintaining a lightweight model of 4366KB. Comparative analysis with existing methods confirmed the proposed method's superiority in accuracy and real-world applicability. This research presents a significant advancement in ECG analysis, offering a viable solution for efficient arrhythmia monitoring in portable healthcare devices.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Blending Ensemble Learning Model for 12-Lead Electrocardiogram-Based Arrhythmia Classification
    Nguyen, Hai-Long
    Pham, Van Su
    Le, Hai-Chau
    COMPUTERS, 2024, 13 (12)
  • [42] Interpretable XGBoost Based Classification of 12-lead ECGs Applying Information Theory Measures From Neuroscience
    Rajpal, Hardik
    Sas, Madalina
    Joakim, Rebecca
    Lockwood, Chris
    Peters, Nicholas S.
    Falkenberg, Max
    2020 COMPUTING IN CARDIOLOGY, 2020,
  • [43] Automated Recognition of Arrhythmia Using Deep Neural Networks for 12-Lead Electrocardiograms with Fractional Time Frequency Domain Extension
    Ge, Chuanbin
    Liu, Di
    Liu, Juan
    Liu, Bingshuai
    Xin, Yi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (11) : 2764 - 2767
  • [44] A Wide and Deep Transformer Neural Network for 12-Lead ECG Classification
    Natarajan, Annamalai
    Chang, Yale
    Mariani, Sara
    Rahman, Asif
    Boverman, Gregory
    Vij, Shruti
    Rubin, Jonathan
    2020 COMPUTING IN CARDIOLOGY, 2020,
  • [45] New System for Digital to Analog Transformation and Reconstruction of 12-Lead ECGs
    Kothadia, Roshni
    Kulecz, Walter B.
    Kofman, Igor S.
    Black, Adam J.
    Grier, James W.
    Schlegel, Todd T.
    PLOS ONE, 2013, 8 (04):
  • [46] A Novel Neural-Network Model for Deriving Standard 12-Lead ECGs From Serial Three-Lead ECGs: Application to Self-Care
    Atoui, Hussein
    Fayn, Jocelyne
    Rubel, Paul
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 883 - 890
  • [47] A Novel Multi-Scale Convolutional Neural Network for Arrhythmia Classification on Reduced-Lead ECGs
    Xia, Pan
    He, Zhengling
    Zhu, Yusi
    Bai, Zhongrui
    Yu, Xianya
    Wang, Yuqi
    Geng, Fanglin
    Du, Lidong
    Chen, Xianxiang
    Wang, Peng
    Fang, Zhen
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [48] Multi-label arrhythmia classification using 12-lead ECG based on lead feature guide network
    Cheng, Yuhao
    Li, Deyin
    Wang, Duoduo
    Chen, Yuhang
    Wang, Lirong
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2024, 129
  • [49] A Hybrid System with Hidden Markov Models and Gaussian Mixture Models for Myocardial Infarction Classification with 12-Lead ECGs
    Chang, Pei-Chann
    Hsieh, Jui-Chien
    Lin, Jyun-Jie
    Chou, Yen-Hung
    Liu, Chen-Hao
    HPCC: 2009 11TH IEEE INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING AND COMMUNICATIONS, 2009, : 110 - +
  • [50] Multi-Label Classification of 12-lead ECGs by Using Residual CNN and Class-Wise Attention
    Liu, Yang
    Wang, Kuanquan
    Yuan, Yongfeng
    Li, Qince
    Li, Yacong
    Xu, Yongpeng
    Zhang, Henggui
    2020 COMPUTING IN CARDIOLOGY, 2020,