Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

被引:28
|
作者
Sartoretti, Thomas [1 ,2 ,3 ]
Mcdermott, Michael [2 ,3 ,4 ]
Mergen, Victor [1 ]
Euler, Andre [1 ]
Schmidt, Bernhard [5 ]
Jost, Gregor [4 ]
Wildberger, Joachim [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[3] Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers, Forchheim, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1143期
关键词
Computed Tomography Angiography; Coronary Vessels; Photons; Phantoms; Imaging; COMPUTED-TOMOGRAPHY; CONTRAST-MEDIA; STENOSIS; PHANTOM;
D O I
10.1259/bjr.20220466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA).Methods: CCTA with PCD- CT (prospective ECG -triggering, 120 kVp, automatic tube current modulation) was performed in a high -end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR- off) and with all quantum iterative reconstruction (QIR) levels (QIR- 1 to 4). In the phantom, noise power spectrum, vessel atten-uation, contrast - to-noise -ratio (CNR), and vessel sharp-ness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronaryartery plaque delineation on 5 -point Likert scales in patients.Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR- 4 to 40 keV QIR- off. Reconstructions at 40 keV QIR- 4 exhibited the highest CNR (46.1 +/- 1.8), vessel sharpness (425 +/- 42 increment HU/mm), and vessel atten-uation (1098 +/- 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR- 3 and QIR- 4 images received the best scores (p < 0.001).Conclusion: Forty keV VMI with QIR- 4 significantly improved image quality of CCTA with PCD- CT. Advances in knowledge: PCD- CT at 40 keV and QIR- 4 improves image quality of CCTA.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Photon- Counting Detector CT With Denoising for Imaging of the Osseous Pelvis at Low Radiation Doses: A Phantom Study
    Marcus, Roy P.
    Nagy, Daniel A.
    Feuerriegel, Georg C.
    Anhaus, Julian
    Nanz, Daniel
    Sutter, Reto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)
  • [32] Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality (Feb, 10.1148/radiol.211931, 2022)
    Sartoretti, Thomas
    Landsmann, Anna
    Nakhostin, Dominik
    Eberhard, Matthias
    Roeren, Christian
    Mergen, Victor
    Higashigaito, Kai
    Raupach, Rainer
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 304 (03) : E55 - E55
  • [33] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [34] Improved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography
    D'Angelo, Tommaso
    Lanzafame, Ludovica R. M.
    Micari, Antonino
    Blandino, Alfredo
    Yel, Ibrahim
    Koch, Vitali
    Gruenewald, Leon D.
    Vogl, Thomas J.
    Booz, Christian
    Bucolo, Giuseppe M.
    Cannizzaro, Maria Teresa
    Ascenti, Giorgio
    Mazziotti, Silvio
    DIAGNOSTICS, 2023, 13 (16)
  • [35] Impact of Contrast Enhancement and Virtual Monoenergetic Image Energy Levels on Emphysema Quantification Experience With Photon-Counting Detector Computed Tomography
    Jungblut, Lisa
    Kronenberg, Daniel
    Mergen, Victor
    Higashigaito, Kai
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 359 - 365
  • [36] Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography
    Chamberlin, Jordan H.
    Toth, Adrienn
    Hinen, Shaun
    O'Doherty, Jim
    Baruah, Dhiraj
    Maisuria, Dhruw
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e63 - e69
  • [37] Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images
    Nakashima, Masahiro
    Kawai, Tatsuya
    Matsumoto, Kazuhisa
    Kawaguchi, Takatsune
    Kitera, Nobuo
    Watanabe, Seita
    Itoh, Toshihide
    Hiwatashi, Akio
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [38] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [39] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [40] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786