Multi-functional voltage and current based enhancement of power quality in grid-connected microgrids considering harmonics

被引:7
|
作者
Akbari, Ehsan [1 ]
Seyyedi, Abbas Zare Ghaleh [2 ]
机构
[1] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol, Iran
[2] Shiraz Univ Technol, Dept Elect & Elect Engn, Shiraz, Iran
关键词
MFGTI; RES; Voltage sag/swell; Harmonic; INVERTERS; COMPENSATION;
D O I
10.1016/j.heliyon.2024.e26008
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The introduction of a renewable energy source (RES) based multi-functional grid-tied inverter (MFGTI) stands as a favorable remedy for addressing power quality concerns within distributed generation (DG) systems and microgrids. Nonetheless, the effectiveness of a traditional MFGTI will be restricted in addressing power quality issues based on voltage. The presented research proposes a novel structure for MFGTI to enhance power quality concerns associated with voltage, current, and harmonic distortions resulting from both grid and loads. Based on this strategy, the introduced MFGTI can be linked with the grid by bidirectional switches either in a parallel or series. This feature provides various operational conditions in response to diverse disruptions in the grid. To effectively adjust the voltage, current and voltage reduction are determined through mathematical analysis, considering both the grid conditions and the load requirements. Furthermore, this strategy offers different compensation strategies, control schemes, and transition modes in the MFGTI. The major disturbances such as unbalanced and balanced voltage swell/ sag, harmonics, and interruption are compensated. The shunt compensation controller is based on a second order sequence filter (SOSF) to provide the load current active component. A damping PI regulator based series compensation controller is presented for the voltage swell/sag reduction. Moreover, a new three level hierarchical control is proposed in which a droop control for compensating the interruption and a decouple dual synchronous reference frame (DDSRF) for compensating the unbalanced voltage sag/swell are utilized. The simulations in the MATLAB/ SIMULINK show that using the proposed compensation strategies, the proposed MFGTI can compensate effectively the different disturbances through changing the transition states by the proposed algorithm based bidirectional switches.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Cascaded Current-Voltage Control to Improve the Power Quality for a Grid-Connected Inverter With a Local Load
    Zhong, Qing-Chang
    Hornik, Tomas
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (04) : 1344 - 1355
  • [42] A Multi-Functional Grid-Connected Inverter and Its Application in the All-Electric Ship
    Zhou, Lei
    Liu, Hongda
    Xu, Ying
    Bai, Lipeng
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [43] A multi-functional grid-connected inverter and its application in micro-grid access to distribution system
    School of Automation, Harbin Engineering University, Harbin 150001, Heilongjiang Province, China
    Zhongguo Dianji Gongcheng Xuebao, 16 (2649-2658):
  • [44] Multi-Functional Double Mode Inverter for Power Quality Enhancement in Smart-Grid Applications
    Harirchi, F.
    Simoes, M. Godoy.
    Babakmehr, M.
    AlDurra, A.
    Muyeen, S. M.
    Bubshait, A.
    2016 52ND ANNUAL MEETING OF THE IEEE INDUSTRY APPLICATIONS SOCIETY (IAS), 2016,
  • [45] Power quality assessment of grid-connected wind farms considering regulations in turkey
    Kocatepe, Celal
    Inan, Asian
    Arikan, Oktay
    Yumurtaci, Recep
    Kekezoglu, Bedri
    Baysal, Mustafa
    Bozkurt, Altug
    Akkaya, Yener
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (09): : 2553 - 2561
  • [46] Control Scheme for Negative-Sequence Voltage Compensation and Current Sharing in Inverter-Based Grid-Connected Microgrids
    Castilla, Miguel
    Velasco, Manel
    Miret, Jaume
    Borrell, Angel
    Guzman, Ramon
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6556 - 6567
  • [47] Enhancement of power quality on grid connected dual voltage source inverter
    Gomathi, S.
    Venkatesan, T.
    Tharanya, S.
    PROCEEDINGS OF 2015 ONLINE INTERNATIONAL CONFERENCE ON GREEN ENGINEERING AND TECHNOLOGIES (IC-GET), 2015,
  • [48] Microgrid Harmonic Mitigation Strategy Based on the Optimal Allocation of Active Power and Harmonic Mitigation Capacities of Multi-Functional Grid-Connected Inverters
    Wang, Ning
    Zheng, Shuai
    Gao, Weiqiang
    ENERGIES, 2022, 15 (17)
  • [49] A novel rolling optimization strategy considering grid-connected power fluctuations smoothing for renewable energy microgrids
    Li, Shenglin
    Zhu, Jizhong
    Dong, Hanjiang
    Zhu, Haohao
    Fan, Junwei
    APPLIED ENERGY, 2022, 309
  • [50] A Grid-Connected Dual Voltage Source Inverter With Power Quality Improvement Features
    Kumar, M. V. Manoj
    Mishra, Mahesh K.
    Kumar, Chandan
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (02) : 482 - 490