Clinical Outcomes and Complications of Primary Fingertip Reconstruction Using a Reverse Homodigital Island Flap: A Systematic Review

被引:6
|
作者
Xu, Joshua [1 ,2 ,5 ]
Cao, Jacob Y. [1 ]
Graham, David J. [3 ]
Lawson, Richard D. [2 ]
Sivakumar, Brahman S. [2 ,4 ]
机构
[1] Univ Sydney, Camperdown, NSW, Australia
[2] Royal North Shore Hosp, St Leonards, NSW, Australia
[3] Gold Coast Univ Hosp, Southport, Qld, Australia
[4] Hornsby Ku Ring Gai Hosp, Sydney, NSW, Australia
[5] Royal North Shore Hosp, Dept Hand & Peripheral Nerve Surg, Reserve Rd, St Leonards, NSW 2065, Australia
来源
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY | 2023年 / 18卷 / 02期
关键词
flap; homodigital; reverse-flow; finger; fracture/dislocation; diagnosis; trauma; microsurgery; specialty; systematic review; ARTERY FLAP; INJURIES;
D O I
10.1177/15589447211003179
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundReverse homodigital island flaps (RHIFs) are increasingly used to reconstruct traumatic fingertip injuries, but there is limited evidence on the efficacy of this technique. We performed a systematic review of the literature to establish the safety and functional outcomes of RHIF for traumatic fingertip injuries.MethodsElectronic searches were performed using 3 databases (PubMed, Ovid Medline, Cochrane CENTRAL) from their date of inception to April 2020. Relevant studies were required to report on complications and functional outcomes for patients undergoing RHIF for primary fingertip reconstruction. Data were extracted from included studies and analyzed.ResultsSixteen studies were included, which produced a total cohort of 459 patients with 495 fingertip injuries. The index and middle fingers were involved most frequently (34.6% and 34.1%, respectively), followed by the ring finger (22%), the little finger (6.7%), and the thumb (2.6%). The mean postoperative static and moving 2-point discrimination was 7.2 and 6.7 mm, respectively. The mean time to return to work was 8.4 weeks. The mean survivorship was 98.4%, with the pooled complication rate being 28%. The pooled complication rate of complete flap necrosis was 3.6%, of partial flap necrosis was 10.3%, of venous congestion was 14.6%, of pain or hypersensitivity was 11.5%, of wound infection was 7.2%, of flexion contractures was 6.3%, and of cold intolerance was 17.7%.ConclusionsReverse homodigital island flaps can be performed safely with excellent outcomes. To minimize complications, care is taken during dissection and insetting, with extensive rehabilitation adhered to postoperatively. Prospective studies assessing outcomes of RHIF compared with other reconstruction techniques would be beneficial.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 50 条
  • [21] Homodigital artery flap reconstruction for fingertip amputation: a comparative study of the oblique triangular neurovascular advancement flap and the reverse digital artery island flap
    Usami, S.
    Kawahara, S.
    Yamaguchi, Y.
    Hirase, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (03) : 291 - 297
  • [22] Reverse Midpalmar Island Flap Transfer for Fingertip Reconstruction
    Omokawa, Shohei
    Fujitani, Ryotaro
    Dohi, Yoshihiro
    Tanaka, Yasuhito
    Yajima, Hiroshi
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2009, 25 (03) : 171 - 179
  • [23] Reconstruction of fingertip defects with the anterograde homodigital neuroarterial island flap under local anesthesia
    Chen, Linhai
    Zhao, Dehua
    Wei, Peng
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (01): : 461 - 463
  • [24] Comparative Study of the Clinical Effects of Reverse Digital Artery Island Flaps and Antegrade Homodigital Neurovascular Island Flaps for Fingertip Reconstruction
    Xiong, Xu
    Xu, Min
    Shuai, Ming
    Guo, Chao-Jian
    Wang, Chao
    He, Zhi-Ling
    Li, Hao
    ANNALS OF PLASTIC SURGERY, 2022, 88 (04) : 395 - 400
  • [25] The reconstruction of a dorsal digital defect using reverse homodigital island flap incorporating vascularized tendon
    Tonkin, MA
    Ahmad, TS
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (06): : 750 - 751
  • [26] Comparison of Innervated Digital Artery Perforator Flap Versus Homodigital Reverse Flow Flap Techniques for Fingertip Reconstruction
    Gulec, Ali
    Ozdemir, Ali
    Durgut, Fatih
    Yildirim, Ahmet
    Acar, Mehmet Ali
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (09): : 801.e1 - 801.e6
  • [27] Innervated reverse dorsal digital island flap for fingertip reconstruction
    Takeishi, Meisei
    Shinoda, Akihiko
    Sugiyama, Atsuki
    Ui, Keito
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (07): : 1094 - 1099
  • [28] Homodigital Pedicled Digital Artery Perforator flaps for fingertip reconstruction - a review of flap options
    Khan, Waseem-Ullah
    Appukuttan, Aswin
    Loh, Charles Yuen Yung
    JPRAS OPEN, 2022, 34 : 199 - 218
  • [29] POSTOPERATIVE VOLUMINAL FLAP REDUCTION AFTER FINGERTIP RECONSTRUCTION USING THE REVERSE DIGITAL ARTERY ISLAND FLAP
    Usami, Satoshi
    Kodaira, Satoshi
    Homma, Tsutomu
    Okazaki, Mutsumi
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2015, 20 (01): : 133 - 136
  • [30] A HOMODIGITAL REVERSE PEDICLE ISLAND FLAP IN SOFT-TISSUE RECONSTRUCTION OF THE FINGER AND THE THUMB
    NIRANJAN, NS
    ARMSTRONG, JR
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (02): : 135 - 141