Development and validation of an optimal GATE model for proton pencil-beam scanning delivery

被引:2
|
作者
Asadi, Ali [1 ]
Akhavanallaf, Azadeh [2 ]
Hosseini, Seyed Abolfazl [1 ]
Vosoughi, Naser [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ,6 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Geneva, Neuroctr, Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
基金
瑞士国家科学基金会;
关键词
Proton therapy; Monte Carlo simulation; active scanning; AAPM TG-119; prostate; MONTE-CARLO SIMULATIONS; CARBON-ION THERAPY; DOSE-CALCULATION; OPTIMIZATION; CODE; DISTRIBUTIONS; PARAMETERS; EQUIVALENT; PLATFORM; TOPAS;
D O I
10.1016/j.zemedi.2022.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To develop and validate a versatile Monte Carlo (MC)-based dose calculation engine to support MC-based dose verification of treatment planning systems (TPSs) and quality assurance (QA) workflows in proton therapy. Methods: The GATE MC toolkit was used to simulate a fixed horizontal active scan-based proton beam delivery (SIEMENS IONTRIS). Within the nozzle, two primary and secondary dose monitors have been designed to enable the comparison of the accuracy of dose estimation from MC simulations with respect to physical QA measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers (IC) in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of the AAPM TG-119 (c-shape phantom) and a prostate patient. Results: MC simulations showed excellent agreement with measurements in the lateral depth-dose parameters and spread-out Bragg peak (SOBP) characteristics within a maximum relative error of 0.95 mm in range, 1.83% in entrance to peak ratio, 0.27% in mean point-to-point dose difference, and 0.32% in peak location. The mean relative absolute difference between MC simulations and measurements in terms of absorbed dose in the SOBP region was 0.93% +/- 0.88%. Clinical phantom studies showed a good agreement compared to research TPS (relative error for TG-119 planning target volume PTV-D95 = 1.8%; and for prostate PTV-D95 = -0.6%). Conclusion: We successfully developed a MC model for the pencil beam scanning system, which appears reliable for dose verification of the TPS in combination with QA information, prior to patient treatment.
引用
收藏
页码:591 / 600
页数:10
相关论文
共 50 条
  • [31] Implementation of apertures in a proton pencil-beam dose algorithm
    Depauw, N.
    Kooy, H. M.
    Daartz, J.
    Bussiere, M.
    Batin, E.
    Madden, T.
    Williams, M.
    Schueman, J.
    Clasie, B. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [32] Pencil-beam scanning for pediatric rhabdomyosarcoma: Promise and precautions
    Ladra, Matthew M.
    Wang, Ken Kang-Hsin
    Terezakis, Stephanie A.
    PEDIATRIC BLOOD & CANCER, 2016, 63 (10) : 1698 - 1699
  • [33] Flat-panel imager energy-dependent proton radiography for a proton pencil-beam scanning system
    Harms, Joseph
    Maloney, Luke
    Sohn, James J.
    Erickson, Anna
    Lin, Yuting
    Zhang, Rongxiao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14):
  • [34] Collimated proton pencil-beam scanning for superficial targets: impact of the order of range shifter and aperture
    Baeumer, C.
    Janson, M.
    Timmermann, B.
    Wulff, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08):
  • [35] Evaluation of a Pencil-Beam Scanning Proton Radiography System Using a Flat-Panel Imager
    Harms, J.
    Maloney, L.
    Sohn, J.
    Lin, Y.
    Gao, H.
    Erickson, A.
    Liu, T.
    Zhang, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E475 - E475
  • [36] Penumbra Sharpening by Adaptive Aperture for Mevion Hyperscan Pencil-Beam Scanning Proton Therapy System
    Jin, H.
    Chen, Y.
    Kendall, E.
    Ahmad, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E98 - E98
  • [37] Evaluation of the range shifter model for proton pencil-beam scanning for the Eclipse v.11 treatment planning system
    Matysiak, Witold
    Yeung, Daniel
    Slopsema, Roelf
    Li, Zuofeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 391 - 404
  • [38] Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
    Hyer, Daniel E.
    Bennett, Laura C.
    Geoghegan, Theodore J.
    Bues, Martin
    Smith, Blake R.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 73 - 83
  • [39] Clinical Validation of Proton Pencil Beam Scanning on an Anthropomorphic Lung Phantom
    Wang, P.
    Tang, S.
    Cummings, D.
    Lee, A. K.
    Chang, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E736 - E736
  • [40] Pencil-beam Delivery Pattern Optimization Increases Dose Rate for Stereotactic FLASH Proton Therapy
    Santo, Rodrigo Jose
    Habraken, Steven J. M.
    Breedveld, Sebastiaan
    Hoogeman, Mischa S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 115 (03): : 759 - 767