Integrated control algorithm for fast and accurate detection of the voltage sag with low voltage ride-through (LVRT) enhancement for doubly-fed induction (DFIG) based wind turbines

被引:14
|
作者
Chakraborty, Arindam [1 ]
Maity, Tanmoy [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Indian Sch Mines, Dhanbad 826004, Jharkhand, India
关键词
Doubly fed induction generator (DFIG); Low voltage ride-through (LVRT); Second-order generalized integrator-quadrature signal generator-frequency locked; loop (SOGI-QSG-FLL); Interval type-2 fuzzy logic-proportional; integral (IT2-FLC-PI) controller; Voltage sag detection algorithm (VSDA); DIRECT POWER-CONTROL; FUZZY-LOGIC SYSTEMS; CAPABILITY ENHANCEMENT; DYNAMIC-BEHAVIOR; GENERATOR; DESIGN; IMPLEMENTATION;
D O I
10.1016/j.conengprac.2022.105393
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Low voltage ride-through (LVRT) is one of the essential aspects of grid codes for integrating doubly-fed induction generators (DFIG) to achieve reliable and uninterrupted electrical power generation. The detection time of the voltage sag is one of the crucial aspects for the LVRT improvement of the DFIG. This paper introduces a second-order generalized integrator (SOGI), quadrature signal generator (QSG) with a frequency locked loop (FLL) based algorithm to detect the symmetrical voltage sag fast and accurately. The proposed SOGI-QSG-FLL-based voltage sag detection algorithm (VSDA) works under a second-order band-pass filter with an alfa-beta stationary reference frame. The proposed VSDA is integrated with the novel feed-forward transient current compensation (FFTCC) scheme with an advanced interval type-2 fuzzy logic-proportional integral (IT2-FLC-PI) controller to enhance the LVRT capability of the DFIG. This FFTCC scheme is activated after the detection of voltage sag by using the proposed VSDA. The proposed FFTCC feeds the uninterrupted active and reactive power to the grid and reduces the torque ripple of the DFIG. The detection time of voltage sag by using the proposed VSDA is compared with existing algorithms. The experimental results are also presented to validate the proposed algorithm.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Control Method of the Low Voltage Ride Through in the Doubly-Fed Induction Generator Wind Turbine
    Liu, Fang
    Mei, Mingwei
    Pan, Juntao
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 7600 - 7605
  • [22] Dynamic Characteristic Analysis of Doubly-fed Induction Generator Low Voltage Ride-through
    Shi, L.
    Chen, N.
    Lu, Q.
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1526 - 1534
  • [23] Doubly fed induction generator wind turbines: A novel integrated protection circuit for low-voltage ride-through strategy
    Justo, Jackson John
    Mwasilu, Francis
    Jung, Jin-Woo
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (05)
  • [24] Enhancement of Low Voltage Ride Through (LVRT) Capability of DFIG-Based Wind Turbines with Enhanced Demagnetization Control Model
    Dosoglu, M. Kenan
    Dogan, Muhsin Ugur
    ENERGIES, 2024, 17 (16)
  • [25] Effect of Low Voltage Ride-Through Capability of Doubly-Fed Induction Generator Wind Turbines for Transient Stability of Small Power Producer
    Romphochai, Sillawat
    Hongesombut, Komsan
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2018,
  • [26] High Voltage Ride-Through of DFIG-based Wind Turbines
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Koch, F.
    Erlich, I.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1477 - 1484
  • [27] Low Voltage Ride-Through Enhancement in DFIG-Based Wind Turbine
    Gatavi, Ehsan
    Hellany, Ali
    Nagrial, Mahmood
    Rizk, Jamal
    2016 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2016,
  • [28] Fault analysis of doubly fed induction generator wind turbines with low-voltage ride-through capability
    Bi, Tian-Shu
    Liu Su-Mei
    Xue, An-Cheng
    Yang, Qi-Xun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2013, 41 (02): : 26 - 31
  • [29] Low voltage ride-through control strategy of doubly fed induction generator
    Zhang, Yang
    Huang, Keyuan
    Huang, Shoudao
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 : 153 - 158
  • [30] A review on low voltage ride-through technologies and prospect for DFIG wind turbines
    He, Y. (ykhe@zju.edu.cn), 1600, Automation of Electric Power Systems Press (37):