Integrated control algorithm for fast and accurate detection of the voltage sag with low voltage ride-through (LVRT) enhancement for doubly-fed induction (DFIG) based wind turbines

被引:14
|
作者
Chakraborty, Arindam [1 ]
Maity, Tanmoy [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Indian Sch Mines, Dhanbad 826004, Jharkhand, India
关键词
Doubly fed induction generator (DFIG); Low voltage ride-through (LVRT); Second-order generalized integrator-quadrature signal generator-frequency locked; loop (SOGI-QSG-FLL); Interval type-2 fuzzy logic-proportional; integral (IT2-FLC-PI) controller; Voltage sag detection algorithm (VSDA); DIRECT POWER-CONTROL; FUZZY-LOGIC SYSTEMS; CAPABILITY ENHANCEMENT; DYNAMIC-BEHAVIOR; GENERATOR; DESIGN; IMPLEMENTATION;
D O I
10.1016/j.conengprac.2022.105393
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Low voltage ride-through (LVRT) is one of the essential aspects of grid codes for integrating doubly-fed induction generators (DFIG) to achieve reliable and uninterrupted electrical power generation. The detection time of the voltage sag is one of the crucial aspects for the LVRT improvement of the DFIG. This paper introduces a second-order generalized integrator (SOGI), quadrature signal generator (QSG) with a frequency locked loop (FLL) based algorithm to detect the symmetrical voltage sag fast and accurately. The proposed SOGI-QSG-FLL-based voltage sag detection algorithm (VSDA) works under a second-order band-pass filter with an alfa-beta stationary reference frame. The proposed VSDA is integrated with the novel feed-forward transient current compensation (FFTCC) scheme with an advanced interval type-2 fuzzy logic-proportional integral (IT2-FLC-PI) controller to enhance the LVRT capability of the DFIG. This FFTCC scheme is activated after the detection of voltage sag by using the proposed VSDA. The proposed FFTCC feeds the uninterrupted active and reactive power to the grid and reduces the torque ripple of the DFIG. The detection time of voltage sag by using the proposed VSDA is compared with existing algorithms. The experimental results are also presented to validate the proposed algorithm.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement
    Yan, Yan
    Wang, Meng
    Song, Zhan-Feng
    Xia, Chang-Liang
    ENERGIES, 2012, 5 (11): : 4758 - 4778
  • [2] Analysis on Low Voltage Ride-Through Techniques for Wind Turbines Using Doubly-Fed Induction Generator
    Han Shunjie
    Han Meng
    Han Yue
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [3] Low Voltage Ride-Through Control of Doubly-Fed Induction Generator at Synchronism
    Binh, N. V.
    Hofmann, W.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 803 - 809
  • [4] Coordinated Control Approaches for Low-Voltage Ride-Through Enhancement in Wind Turbines With Doubly Fed Induction Generators
    Rahimi, Mohsen
    Parniani, Mostafa
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) : 873 - 883
  • [5] Hybrid control approach for low-voltage ride-through capability in doubly-fed induction generator-based wind turbines
    Dosoglu, M. Kenan
    COMPUTERS & ELECTRICAL ENGINEERING, 2021, 90
  • [6] Low voltage ride-through control of doubly-fed induction generator wind turbines with a series grid-side converter
    Yao, Jun
    Liao, Yong
    Li, Hui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (06): : 98 - 103
  • [7] Research on Low and High Voltage Interlocking Fault Ride-Through Control Strategy for Doubly-Fed Wind Turbines
    Zhu, Darui
    Cheng, Jiakang
    Chen, Jie
    Duan, Jiandong
    PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 2, ICWPT 2023, 2024, 1159 : 403 - 411
  • [8] Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement
    Rahimi, M.
    Parniani, M.
    IET RENEWABLE POWER GENERATION, 2010, 4 (03) : 242 - 252
  • [9] The Requirements and Technical Analysis of Low Voltage Ride Through for the Doubly-Fed Induction Wind Turbines
    Niu, Chen-guang
    Liu, Guan-qi
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [10] Symmetrical Low Voltage Ride-Through of the Brushless Doubly-Fed Induction Generator
    Shao, Shiyi
    Long, Teng
    Abdi, Ehsan
    McMahon, Richard
    Wu, Yunxiang
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,