Bioaerosol-related studies in wastewater treatment plant with anaerobic-anoxic-oxic processes: Characterization, source analysis, control measures

被引:9
|
作者
Liu, Jianwei [1 ,2 ,4 ]
Ge, Jingyun [1 ,2 ]
Kang, Xinyue [1 ,2 ]
Tian, Hongyu [1 ,2 ,3 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Engn Res Ctr Sustainable Urban Sewage Syst, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
[3] China Univ Min & Technol Beijing, Sch Chem & Environm Engn, Beijing 100083, Peoples R China
[4] Beijing Univ Civil Engn & Architecture, 1 Zhanlan Rd, Beijing 100044, Peoples R China
关键词
Anaerobic-anoxic-oxic process; Bioaerosols; Emission; Effect factors; Interactions; AIRBORNE BACTERIA; OXIDATION DITCH; ESCHERICHIA-COLI; EMISSION; EXPOSURE; SEWAGE; RISK; SIZE; PREVALENCE; RESISTANCE;
D O I
10.1016/j.jenvman.2023.117760
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sewage in wastewater treatment plants (WWTPs) can produce fugitive bioaerosols that pose a health risk to employees and residents. This study aimed to fugitive bioaerosols from two WWTPs with anaerobic-anoxic-oxic (AAO) processes, and bioaerosols control measures were proposed based on the results of these studies. It was found that the bioaerosols were mainly composed of microorganisms from dominant genera such as Romboutsia, Rubellimicrobium, Sphingomonas, Acidea, Cryptotrichosporon and water-soluble ions dominated by SO42-. Moreover, total suspended particulate (TSP), relative humidity (RH), wind speed (WS), Ca2+, NH4+, Na+, Cl-, NO3- ,and K+ had positive effects on most dominant genera, while temperature (T) and SO42- had negative effects on most dominant genera. The source analysis showed that the bioaerosols in the indoor treatment facility's fine screen room and sludge dewatering plant mainly originated from sewage or sludge, and those in the aeration tank of the outdoor treatment facility mainly originated from the background air of WWTPs . By combining the characteristics of bioaerosols and the results of source analysis, targeted control measures were proposed from three aspects: source reduction of bioaerosol fugitives, control of bioaerosol propagation, and collection and treatment systems. This study provides the theoretical basis and ideas for controlling bioaerosols in WWTPs with AAO processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Excess sludge conditioning with ultrasound/ozone and its effect on the anaerobic anoxic oxic process in a municipal wastewater treatment plant
    Ren, Hongyang
    Wang, Yan
    Wei, Zijing
    Liu, Puzhen
    Wang, Bing
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 140 (140) : 170 - 177
  • [42] Microbial community changes in a full-scale wastewater treatment system with a rotating biological contactor integrated into anaerobic-anoxic-oxic-oxic processes
    Bi, Yeliang
    Han, Zhenfei
    Feng, Shugeng
    Wang, Xu
    Xu, Zhanjun
    Zhang, Yuxiu
    Su, Hui
    Zhuang, Xuliang
    Xu, Shengjun
    DESALINATION AND WATER TREATMENT, 2021, 228 : 165 - 175
  • [43] Achieving and control of partial denitrification in anoxic-oxic process of real municipal wastewater treatment plant
    Liu, Xiuhong
    Liu, Runyu
    Yang, Qing
    Cui, Bin
    Wu, Wenjun
    Zhao, Xiaoyin
    Wang, Yaxin
    BIORESOURCE TECHNOLOGY, 2021, 341
  • [44] Effect of internal recycle on the nitrogen removal efficiency of an anaerobic/anoxic/oxic (A2/O) wastewater treatment plant (WWTP)
    Baeza, JA
    Gabriel, D
    Lafuente, J
    PROCESS BIOCHEMISTRY, 2004, 39 (11) : 1615 - 1624
  • [45] Spatiotemporal distribution of microorganisms in a full-scale anaerobic baffled reactor-anoxic/oxic treatment plant for printing and dyeing wastewater
    Xu, Ming
    Gao, Peng
    Chen, Hao-qiang
    Huang, Xing-hao
    Xue, Zhao-xia
    Shen, Xiao-xiao
    Li, Chao
    Cao, Jia-shun
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 49
  • [46] Control of anaerobic-anoxic-aerobic (A2/O) processes in wastewater treatment: a detailed review
    Sheik A.G.
    Tejaswini E.S.S.
    Seepana M.M.
    Ambati S.R.
    Environmental Technology Reviews, 2023, 12 (01) : 420 - 440
  • [47] Insights into the bacterial species and communities of a full-scale anaerobic/anoxic/oxic wastewater treatment plant by using third-generation sequencing
    Ji, Bin
    Zhang, Xuechun
    Zhang, Shufei
    Song, Hongjiao
    Kong, Zehua
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2019, 128 (06) : 744 - 750
  • [48] Metagenomics approach and canonical correspondence analysis of novel nitrifiers and ammonia-oxidizing archaea in full scale anaerobic-anoxic-oxic (A2/O) and oxidation ditch processes
    Park, Jun-Gyu
    Lee, Beom
    Heo, Tae-Young
    Cheon, A-In
    Jun, Hang-Bae
    BIORESOURCE TECHNOLOGY, 2021, 319
  • [49] Characterization of dissolved organic matter in wastewater during aerobic, anaerobic, and anoxic treatment processes by molecular size and fluorescence analyses
    Komatsu, Kazuhiro
    Onodera, Takashi
    Kohzu, Ayato
    Syutsubo, Kazuaki
    Imai, Akio
    WATER RESEARCH, 2020, 171
  • [50] Reduction and prediction of N2O emission from an Anoxic/Oxic wastewater treatment plant upon DO control and model simulation
    Sun, Shichang
    Bao, Zhiyuan
    Li, Ruoyu
    Sun, Dezhi
    Geng, Haihong
    Huang, Xiaofei
    Lin, Junhao
    Zhang, Peixin
    Ma, Rui
    Fang, Lin
    Zhang, Xianghua
    Zhao, Xuxin
    BIORESOURCE TECHNOLOGY, 2017, 244 : 800 - 809