Correction method for 3D non-linear drift distortions in atomic force microscopy raster measurements

被引:2
|
作者
Degenhardt, Johannes [1 ]
Tutsch, Rainer [2 ]
Dai, Gaoliang [1 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
[2] TU Braunschweig, Inst Prod Metrol, Braunschweig, Germany
关键词
atomic force microscopy; scanning probe microscopy; drift correction; nanometrology;
D O I
10.1088/1361-6501/ac9992
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method to correct non-linear drift distortions in all three coordinate axes of atomic force microscope (AFM) images is presented. The method uses two measurements of the sample with two fast scan axes orthogonal to each other. Both AFM images are divided into segments and the shifts of the surface features of the segments of both images are determined. From these shifts subsequently the drift of both measurements is calculated. Depending on the segments used, significant non-linearities of the drift can be corrected. The two required measurements for this method do not have to be carried out in direct succession. With this method it is therefore possible to correct drift in an existing AFM image by measuring the sample again later. Although the method has been developed for AFM, it can also be used for other scanning probe microscopes.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Non-Linear 3D Impedance Spectroscopy
    Zamora, M.
    Trujillo, M.
    Felice, C.
    IEEE LATIN AMERICA TRANSACTIONS, 2014, 12 (05) : 895 - 898
  • [12] Benchmarking of a 3D non-linear lifting line method against 3D RANSE simulations
    Duport, Chloe
    Leroux, Jean-Baptiste
    Roncin, Kostia
    Jochum, Christian
    Parlier, Yves
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 2019, (5-6): : 70 - 73
  • [13] Sample drift correction in 3D fluorescence photoactivation localization microscopy
    Mlodzianoski, Michael J.
    Schreiner, John M.
    Callahan, Steven P.
    Smolkova, Katarina
    Dlaskova, Andrea
    Santorova, Jitka
    Jezek, Petr
    Bewersdorf, Joerg
    OPTICS EXPRESS, 2011, 19 (16): : 15009 - 15019
  • [14] Probing linear and non-linear tip-sample interaction forces by atomic force acoustic microscopy
    Rabe, U
    Kester, E
    Arnold, W
    SURFACE AND INTERFACE ANALYSIS, 1999, 27 (5-6) : 386 - 391
  • [15] STABILITY ANALYSIS OF AN EXTRAPOLATED FORCE CORRECTION METHOD FOR NON-LINEAR STRUCTURAL DYNAMICS
    TRUJILLO, DM
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1982, 49 (01): : 203 - 205
  • [16] Combining computer vision and atomic force microscopy for 3D reconstruction
    Allard, Charlotte
    NATURE REVIEWS MATERIALS, 2024, 9 (10): : 673 - 673
  • [17] 3D reconstruction of atomic force microscopy (AFM) image data
    Williams, P.
    JOURNAL OF ANATOMY, 2006, 209 (03) : 416 - 417
  • [18] Fabrication of 3D Structures using Atomic Force Microscopy scratching
    Brousseau, E. B.
    Scholz, S.
    Rees, A.
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MULTI-MATERIAL MICRO MANUFACTURE (4M 2010), 2011, : 65 - 68
  • [19] Adaptive FEM in 3D non-linear magnetostatics
    Alotto, P
    Castagnini, A
    Girdinio, P
    Nervi, M
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2000, 19 (01) : 39 - 47
  • [20] Towards 3D charge localization by a method derived from atomic force microscopy: the electrostatic force distance curve
    Villeneuve-Faure, C.
    Boudou, L.
    Makasheva, K.
    Teyssedre, G.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (45)