The experimental analysis on the influence of different conditions in microchannel on critical heat flux and boiling starting point

被引:5
|
作者
Liu, Xinmin [1 ]
Hua, Junye [1 ]
Lan, Hai [1 ]
Li, Dong [1 ]
Sang, Keyi [1 ]
Liu, Huiyan [1 ]
Zhang, Jing [1 ]
机构
[1] Nanjing Normal Univ NNU, Sch Energy & Mech Engn, Engn Lab Energy Syst Proc Convers & Emiss Reduct T, Nanjing 210042, Peoples R China
关键词
SINGLE-PHASE; PERFORMANCE; SINKS; ENHANCEMENT; FC-72;
D O I
10.1007/s00231-023-03400-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to explore the mechanism of boiling heat transfer in microchannels and the appearance of CHF and ONB under different conditions, a visualized experimental research has been conducted on the flow and heat transfer characteristics in microchannels. Combined with the behaviour of bubbles, the occurrence of ONB and CHF in the microchannels with different shapes, different flow velocities and different inflow directions has been compared and analyzed. Results indicate that, after the heat flux exceeds 20 W/cm(2), the four microchannels all enter the nucleate boiling stage (ONB), with little difference in order. The appearance of ONB for the droplet pin fin is the earliest (q(e) = 41.51 W/cm(2)), with non-closed pin fin with flow direction B (q(e) = 56.65 W/cm(2)) as the latest. Accordingly, the channel with droplet fin (q(e) = 106.2 W/cm(2)) pin fins appear CHF first, and the non-closed droplet shape (flow direction A: q(e) = 141.6 W/cm(2); flow direction B: no CHF) is the latest. While for the same channel, with the increase of mass flow, the convective heat transfer coefficient becomes higher and ONB and CHF will be delayed. For the different layout, the more favorable flow arrangement (flow direction B) is helpful to delay ONB and CHF. A comprehensive factors & eta; is introduced to evaluate the boiling flow and heat transfer performance of the microchannels with different situations. At higher heat flux density (58 W/cm(2)-150 W/cm(2)), flow direction B perform best. Under the discussed condition, the heat flux value as 109.91 W/cm(2), 106.22 W/cm(2), and 143.05 W/cm(2) are the limit values for the CHF, in the square, droplet and non-closed droplet A pin fin arrays. Where, the CHF has not appeared in non-closed droplet B, whose limit value is more than 145 W/cm(.)(2) In general, the results illustrate that the opening structure is helpful for boiling heat transfer. The novel design can prolong the duration of bubble flow in nucleate boiling, which plays a key role in delaying CHF.
引用
收藏
页码:2087 / 2103
页数:17
相关论文
共 50 条
  • [31] AN EXPERIMENTAL-STUDY OF CRITICAL HEAT-FLUX IN VERY HIGH HEAT-FLUX SUBCOOLING BOILING
    VANDERVORT, CL
    BERGLES, AE
    JENSEN, MK
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (SUPPL 1) : 161 - 173
  • [32] The Effect of Nanocoatings on Critical Heat Flux (CHF) under Pool Boiling Conditions
    Reddy, Sadhgun
    Prabhu, K. Narayan
    Nayak, U. Vignesh
    MATERIALS PERFORMANCE AND CHARACTERIZATION, 2021, 10 (01) : 532 - 537
  • [33] Criteria for negating the influence of gravity on flow boiling critical heat flux with two-phase inlet conditions
    Konishi, Christopher
    Mudawar, Issam
    Hasan, Mohammad M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 65 : 203 - 218
  • [34] Impact of pressure drop oscillations and parallel channel instabilities on microchannel flow boiling and critical heat flux
    Clark, Matthew D.
    Weibel, Justin A.
    Garimella, Suresh V.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2023, 161
  • [35] Critical heat flux on flow boiling of methanol-water mixtures in a diverging microchannel with artificial cavities
    Lin, P. H.
    Fu, B. R.
    Pan, Chin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) : 3156 - 3166
  • [36] Analysis of heat transfer under high heat flux nucleate boiling conditions
    Liu, Y.
    Dinh, N.
    KERNTECHNIK, 2016, 81 (03) : 308 - 314
  • [37] DRYOUT INCIPIENCE AND CRITICAL HEAT FLUX IN SATURATED FLOW BOILING OF REFRIGERANTS IN A VERTICAL UNIFORMLY HEATED MICROCHANNEL
    Martin-Callizo, Claudi
    Ali, Rashid
    Palm, Bjorn
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, PTS A AND B, 2008, : 705 - 712
  • [38] Impact of Pressure Drop Oscillations on Surface Temperature and Critical Heat Flux During Flow Boiling in a Microchannel
    Clark, Matthew D.
    Weibel, Justin A.
    Garimella, Suresh, V
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2021, 11 (10): : 1634 - 1644
  • [39] A STUDY ON HIGH HEAT FLUX HEAT REMOVAL WITH BOILING USING POROUS MICROCHANNEL
    Hanzawa, Daiki
    Katsumata, Kyosuke
    Okawa, Tomio
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 5, 2014,
  • [40] Experimental Analysis of Bubble Behavior and Critical Heat Flux During Pool Boiling on Vertical Circular Tubes
    Pattanayak, Bikash
    Kothadia, Hardik B.
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2023, 9 (04):