Construction and Application of an Electrochemical Sensor for Determination of D-Penicillamine Based on Modified Carbon Paste Electrode

被引:7
|
作者
Mohammadnavaz, Arefeh [1 ]
Beitollahi, Hadi [2 ]
Modiri, Sina [3 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman 7631133131, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman 7631133131, Iran
[3] Grad Univ Adv Technol, Polymer Dept, Kerman 7631133131, Iran
关键词
electrocatalytic mechanism; multi-walled carbon nanotubes; Co3O4; nanoparticles; ionic liquid; benzoyl-ferrocene; carbon paste electrode; D-penicillamine; VOLTAMMETRIC DETERMINATION; ELECTROCATALYTIC OXIDATION; SENSITIVE DETECTION; AQUEOUS-MEDIA; IONIC LIQUID; QUANTUM DOTS; HUMAN URINE; NANOPARTICLES; NANOTUBES; FERROCENE;
D O I
10.3390/mi15020220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
D-penicillamine (D-PA) is a sulfur-containing drug that has been used for various health conditions. However, like any medication, overdosing on D-PA can have adverse effects and may require additional treatment. Therefore, developing simple and sensitive methods for sensing D-PA can play a crucial role in improving its efficacy and reducing its side effects. Sensing technologies, such as electrochemical sensors, can enable accurate and real-time measurement of D-PA concentrations. In this work, we developed a novel electrochemical sensor for detecting D-PA by modifying a carbon paste electrode (CPE) with a multi-walled carbon nanotube-Co3O4 nanocomposite, benzoyl-ferrocene (BF), and ionic liquid (IL) (MWCNT-Co3O4/BF/ILCPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CHA) were employed to explore the electrochemical response of D-PA on the developed sensor, the results of which verified a commendable electrochemical performance towards D-PA. Under optimized conditions, the developed sensor demonstrated a rapid response to D-PA with a linear dynamic range of 0.05 mu M-100.0 mu M, a low detection limit of 0.015 mu M, and a considerable sensitivity of 0.179 mu A mu M-1. Also, the repeatability, stability, and reproducibility of the MWCNT-Co3O4/BF/ILCPE sensor were studied and showed good characteristics. In addition, the detection of D-PA in pharmaceutical and biological matrices yielded satisfactory recoveries and relative standard deviation (RSD) values.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [22] Voltammetric Quantification of D-penicillamine by Using a Carbon Paste Electrode Modified with WO3 Nanorods and Ionic Liquid as an Efficient Electrochemical Sensing Platform
    Somayeh Tajik
    Peyman Mohammadzadeh Jahani
    Topics in Catalysis, 2024, 67 : 853 - 863
  • [23] Voltammetric Quantification of D-penicillamine by Using a Carbon Paste Electrode Modified with WO3 Nanorods and Ionic Liquid as an Efficient Electrochemical Sensing Platform
    Tajik, Somayeh
    Jahani, Peyman Mohammadzadeh
    TOPICS IN CATALYSIS, 2024, 67 (9-12) : 853 - 863
  • [24] Electrochemical Determination of Vitamin A Based on a Novel Nanoalloy Modified Carbon Paste Electrode
    Lv, Xiaoshun
    Zhao, Jie
    Dong, Xue
    Tian, Hongshuai
    Qi, Shufang
    Jiang, Yuchan
    Ping, Yiling
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (09): : 8457 - 8466
  • [25] Determination of Methotrexate Using an Electrochemical Sensor Based on Carbon Paste Electrode Modified with NiO Nanosheets and Ionic Liquid
    Jahani, Peyman Mohammadzadeh
    Tajik, Somayeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    Dourandish, Zahra
    CHEMOSENSORS, 2024, 12 (12)
  • [26] Polymer Modified Carbon Paste Electrode as a Sensitive Sensor for the Electrochemical Determination of Riboflavin and Its Application in Pharmaceutical and Biological Samples
    D'Souza, Edwin S.
    Manjunatha, J. G.
    Raril, C.
    Tigari, Girish
    Pushpanjali, P. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 461 - 472
  • [27] A Ruthenium Complex/Carbon Nanotube Based Electrode as the First Electrochemical Sensor for Simultaneous Sensing of D-Penicillamine, 6-Thioguanine and Catecholamines
    Mazloum-Ardakani, Mohammad
    Sheikh-Mohseni, Mohammad Ali
    Salavati-Niasari, Masoud
    ELECTROANALYSIS, 2016, 28 (06) : 1370 - 1376
  • [28] SWCNT-modified carbon paste electrode as an electrochemical sensor for histamine determination in alcoholic beverages
    Stojanovic, Zorica S.
    Mehmeti, Eda
    Kalcher, Kurt
    Guzsvany, Valeria
    Stankovic, Dalibor M.
    FOOD ANALYTICAL METHODS, 2016, 9 (10) : 2701 - 2710
  • [29] SWCNT-modified carbon paste electrode as an electrochemical sensor for histamine determination in alcoholic beverages
    Zorica S. Stojanović
    Eda Mehmeti
    Kurt Kalcher
    Valéria Guzsvány
    Dalibor M. Stanković
    Food Analytical Methods, 2016, 9 : 2701 - 2710
  • [30] Carbon dots as a dual sensor for the selective determination of D-penicillamine and biological applications
    Gunjal, Datta B.
    Gore, Anil H.
    Naik, Vaibhav M.
    Pawar, Samadhan P.
    Anbhule, Prashant V.
    Shejwal, Rajendra V.
    Kolekar, Govind B.
    OPTICAL MATERIALS, 2019, 88 : 134 - 142