Construction and Application of an Electrochemical Sensor for Determination of D-Penicillamine Based on Modified Carbon Paste Electrode

被引:7
|
作者
Mohammadnavaz, Arefeh [1 ]
Beitollahi, Hadi [2 ]
Modiri, Sina [3 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman 7631133131, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman 7631133131, Iran
[3] Grad Univ Adv Technol, Polymer Dept, Kerman 7631133131, Iran
关键词
electrocatalytic mechanism; multi-walled carbon nanotubes; Co3O4; nanoparticles; ionic liquid; benzoyl-ferrocene; carbon paste electrode; D-penicillamine; VOLTAMMETRIC DETERMINATION; ELECTROCATALYTIC OXIDATION; SENSITIVE DETECTION; AQUEOUS-MEDIA; IONIC LIQUID; QUANTUM DOTS; HUMAN URINE; NANOPARTICLES; NANOTUBES; FERROCENE;
D O I
10.3390/mi15020220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
D-penicillamine (D-PA) is a sulfur-containing drug that has been used for various health conditions. However, like any medication, overdosing on D-PA can have adverse effects and may require additional treatment. Therefore, developing simple and sensitive methods for sensing D-PA can play a crucial role in improving its efficacy and reducing its side effects. Sensing technologies, such as electrochemical sensors, can enable accurate and real-time measurement of D-PA concentrations. In this work, we developed a novel electrochemical sensor for detecting D-PA by modifying a carbon paste electrode (CPE) with a multi-walled carbon nanotube-Co3O4 nanocomposite, benzoyl-ferrocene (BF), and ionic liquid (IL) (MWCNT-Co3O4/BF/ILCPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CHA) were employed to explore the electrochemical response of D-PA on the developed sensor, the results of which verified a commendable electrochemical performance towards D-PA. Under optimized conditions, the developed sensor demonstrated a rapid response to D-PA with a linear dynamic range of 0.05 mu M-100.0 mu M, a low detection limit of 0.015 mu M, and a considerable sensitivity of 0.179 mu A mu M-1. Also, the repeatability, stability, and reproducibility of the MWCNT-Co3O4/BF/ILCPE sensor were studied and showed good characteristics. In addition, the detection of D-PA in pharmaceutical and biological matrices yielded satisfactory recoveries and relative standard deviation (RSD) values.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Electrochemical analysis of D-penicillamine using a carbon paste electrode modified with ferrocene carboxylic acid
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Chekin, Freshteh
    ELECTROANALYSIS, 2007, 19 (18) : 1883 - 1889
  • [2] Homogeneous electrocatalytic oxidation of D-penicillamine with ferrocyanide at a carbon paste electrode: application to voltammetric determination
    Raoof, J. B.
    Ojani, R.
    Majidian, M.
    Chekin, F.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (06) : 799 - 805
  • [3] Homogeneous electrocatalytic oxidation of d-penicillamine with ferrocyanide at a carbon paste electrode: application to voltammetric determination
    J. B. Raoof
    R. Ojani
    M. Majidian
    F. Chekin
    Journal of Applied Electrochemistry, 2009, 39 : 799 - 805
  • [4] Catechol as an electrochemical indicator for voltammetric determination of D-penicillamine in aqueous media at the surface of carbon paste electrode
    Jahan-Bakhsh Raoof
    Reza Ojani
    Mohaddeseh Amiri-Aref
    Fereshteh Chekin
    Russian Journal of Electrochemistry, 2012, 48 : 450 - 456
  • [5] Catechol as an electrochemical indicator for voltammetric determination of D-penicillamine in aqueous media at the surface of carbon paste electrode
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Amiri-Aref, Mohaddeseh
    Chekin, Fereshteh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2012, 48 (04) : 450 - 456
  • [6] Voltammetric sensor for D-penicillamine determination based on its electrocatalytic oxidation at the surface of ferrocenes modified carbon paste electrodes
    Jahan-Bakhsh Raoof
    Reza Ojani
    Fereshteh Chekin
    Journal of Chemical Sciences, 2009, 121 : 1083 - 1091
  • [7] Voltammetric sensor for D-penicillamine determination based on its electrocatalytic oxidation at the surface of ferrocenes modified carbon paste electrodes
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Chekin, Fereshteh
    JOURNAL OF CHEMICAL SCIENCES, 2009, 121 (06) : 1083 - 1091
  • [8] A simple method for determination of D-penicillamine on the carbon paste electrode using cupric ions
    Ghaffarinejad, Ali
    Hashemi, Fatemeh
    Nodehi, Zahra
    Salahandish, Razieh
    BIOELECTROCHEMISTRY, 2014, 99 : 53 - 56
  • [9] Electrocatalytic and selective determination of d-penicillamine in the presence of tryptophan using a benzoylferrocene-modified carbon nanotube paste electrode
    Mirrahimi, Fatemeh
    Taher, Mohammad Ali
    Beitollahi, Hadi
    Hosseinzadeh, Rahman
    APPLIED ORGANOMETALLIC CHEMISTRY, 2012, 26 (04) : 194 - 198
  • [10] Novel Carbon Nanotube Paste Electrode for Simultaneous Determination of Norepinephrine, Uric Acid and D-Penicillamine
    Mazloum-Ardakani, Mohammad
    Beitollahi, Hadi
    Ganjipour, Bahram
    Naeimi, Hossein