Magnetic Graphene Oxide Modified with a Surface-Active Ionic Liquid for Ultrasound-Assisted Solid-Phase Extraction (UA-SPE) to Preconcentrate Lenalidomide from Human Plasma with Determination by High-Performance Liquid Chromatography with Ultraviolet Detection (HPLC-UV)

被引:0
|
作者
Movahedi, Farnaz [1 ]
Ezoddin, Maryam [2 ]
Adlnasab, Laleh [3 ]
Shojaei, Rouhallah [2 ]
机构
[1] Stand Res Inst, Chem & Petrochem Res Ctr, Cellulos Mat & Packaging Res Grp, Karaj, Iran
[2] Payame Noor Univ PNU, Dept Chem, Tehran, Iran
[3] Stand Res Inst, Chem & Petrochem Res Ctr, Chem Res Grp, POB 3174-139, Karaj, Iran
关键词
High-performance liquid chromatography with ultraviolet detection (HPLC-UV); lenalidomide; magnetic graphene oxide; surface-active ionic liquid; ultrasound-assisted solid-phase extraction (UA-SPE); SELF-AGGREGATION; METHYLENE-BLUE; REMOVAL; DEXAMETHASONE; NANOPARTICLES; BEHAVIOR; ADSORPTION; SILICA;
D O I
10.1080/00032719.2022.2140434
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new magnetic graphene oxide (MGO) composite was developed as an adsorbent for the preconcentration of lenalidomide (LND) by ultrasound-assisted solid-phase extraction (UA-SPE) prior to determination by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The adsorbent was fabricated through chemical functionalization of a new surface-active ionic liquid (SAIL), i.e. 1-methyl-3-(trimethoxysilyl propyl)-imidazolium dodecyl sulfate (TMES-Im-DS) on MGO. The synthesized material presented the benefits of excellent adsorption for LND. The characterization of the synthesized functionalized magnetic nanocomposite was performed by Fourier transform-infrared spectroscopy, field emission scanning electron microscopy, Brunauer-Emmett-Teller (BET), vibrating sample magnetometry, and energy-dispersive X-ray spectroscopy. After optimization of the parameters, the limits of detection (LOD) and limit of quantification (LOQ) were 0.2 and 0.8 mu g L-1 and 0.6 and 2.5 mu g L(-1)in water and plasma samples, respectively. The enrichment factors (EFs) were from 90 to 180 in the samples. The relative standard deviation (RSD%, n = 5) as intra- and inter-day precision were from 6.3% to 7.5% and 7.1% to 8.5% in water and plasma, respectively. Lastly, the developed method presented good results for the preconcentration of LND in plasma with satisfactory repeatability.
引用
收藏
页码:1685 / 1700
页数:16
相关论文
共 50 条
  • [41] Superparamagnetic graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of tamsulosin hydrochloride in human plasma by high performance liquid chromatography-ultraviolet detection
    Pashaei, Yaser
    Ghorbani-Bidkorbeh, Fatemeh
    Shekarchi, Maryam
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 21 - 29
  • [42] Fully automated analytical method for codeine quantification in human plasma using on-line solid-phase extraction and high-performance liquid chromatography with ultraviolet detection
    Pascual, JA
    Sanagustín, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 724 (02): : 295 - 302
  • [43] Determination of Rhodamine B in Food Using Ionic Liquid-Coated Multiwalled Carbon Nanotube-Based Ultrasound-Assisted Dispersive Solid-Phase Microextraction Followed by High-Performance Liquid Chromatography
    Xu, Xu
    Zhang, Minhui
    Wang, Lingling
    Zhang, Shuming
    Liu, Mingyang
    Long, Na
    Qi, Xinyu
    Cui, Zizheng
    Zhang, Lei
    FOOD ANALYTICAL METHODS, 2016, 9 (06) : 1696 - 1705
  • [44] Multi-residue Determination of Bisphenol Compounds in Feed Using Ultrasound-Assisted Extraction and Dispersive Solid-Phase Extract Followed by High-Performance Liquid Chromatography with Fluorescence Detector
    Lin Xiong
    Jie Pei
    Xiaoyun Wu
    Chunnian Liang
    Xian Guo
    Pengjia Bao
    Min Chu
    Xixi Yao
    Ping Yan
    Chromatographia, 2020, 83 : 1423 - 1433
  • [45] Multi-residue Determination of Bisphenol Compounds in Feed Using Ultrasound-Assisted Extraction and Dispersive Solid-Phase Extract Followed by High-Performance Liquid Chromatography with Fluorescence Detector
    Xiong, Lin
    Pei, Jie
    Wu, Xiaoyun
    Liang, Chunnian
    Guo, Xian
    Bao, Pengjia
    Chu, Min
    Yao, Xixi
    Yan, Ping
    CHROMATOGRAPHIA, 2020, 83 (11) : 1423 - 1433
  • [46] High-throughput determination of faropenem in human plasma and urine by on-line solid-phase extraction coupled to high-performance liquid chromatography with UV detection and its application to the pharmacokinetic study
    Xie, Rui
    Wen, Jun
    Wei, Hua
    Fan, Guorong
    Zhang, Dabing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (01) : 114 - 121
  • [47] Determination of gaseous formaldehyde by derivatization using magnetic multiwalled carbon nanotubes (MWCNTs) modified with 2,4-dinitrophenylhydrazine (DNPH) and high-performance liquid chromatography - ultraviolet detection (HPLC-UV)
    Chen, Songlin
    Cheng, Congliang
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2022, 50 (02) : 174 - 189
  • [48] Trace determination of chlorpheniramine in human plasma using magnetic dispersive solid-phase extraction based on a graphene oxide/Fe3O4@polythionine nanocomposite combined with high-performance liquid chromatography
    Daryakenary, Maryam Ahmadi
    Zeeb, Mohsen
    RSC ADVANCES, 2017, 7 (84) : 53210 - 53218
  • [49] DETERMINATION OF CLOZAPINE AND ITS MAJOR METABOLITES IN HUMAN SERUM USING AUTOMATED SOLID-PHASE EXTRACTION AND SUBSEQUENT ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    WEIGMANN, H
    HIEMKE, C
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 583 (02): : 209 - 216
  • [50] Synthesis of Functionalized Pyridine Modified Magnetic Nanoparticles for Utilization in Magnetic Solid-Phase Extraction of Tebuconazole and Propiconazole Followed by Quantification via High-Performance Liquid Chromatography-Ultraviolet Detection
    Nikbakhsh, Naghmeh
    Ghani, Milad
    Maleki, Behrooz
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)