On post-fire bond strength of steel rebar embedded in thermally-damaged concrete - a review

被引:10
|
作者
Mousavi, Seyed Sina [1 ]
Dehestani, Mehdi [1 ]
Ajarostaghi, Seyed Soheil Mousavi [2 ]
Bhojaraju, Chandrasekhar [3 ]
Phuong Nguyen-Tri [4 ,5 ]
机构
[1] Babol Noshirvani Univ Technol, Dept Civil Engn, Postal Box 484, Babol 4714871167, Iran
[2] Babol Noshirvani Univ Technol, Dept Mech Engn, Babol, Iran
[3] St Joseph Engn Coll, Dept Civil Engn, Mangaluru, India
[4] Univ Quebec Trois Rivieres UQTR, Dept Chem Biochem & Phys, Trois Rivieres, PQ, Canada
[5] Univ Quebec Trois Rivieres UQTR, Lab Adv Mat Energy & Environm, 3351 Blvd Forges, Trois Rivieres, PQ G8Z 4M3, Canada
关键词
Post-fire; residual bond strength; thermally-damaged concrete; steel rebar; high-temperature exposure; FIBER-REINFORCED CONCRETE; DEVELOPMENT LENGTH; FLEXURAL BEHAVIOR; AGGREGATE CONCRETE; BAR BOND; TEMPERATURE; PERFORMANCE; CORROSION; MICROSTRUCTURE; SLABS;
D O I
10.1080/01694243.2021.2025308
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study summarizes the state-of-the-art research progress concerning the influence of high-temperature exposure on the residual bond strength of steel rebar. Also, an experimental database from the literature was collected and analyzed for use in fire safety management in concrete design codes and specifications for high important reinforced concrete (RC) structures, such as public health-care buildings, to reduce and mitigate the risk of thermal damages, especially in steel-congested areas. Different vital variables are debated in the present review, including concrete cover-to-rebar diameter ratio, rebar deformation, fiber addition, transverse confinement, aggregate type, concrete water-to-binder ratio, concrete type, cooling regime, thermal loading regime, and heating exposure time. The review shows that high-temperature exposure significantly reduces the residual bond strength. It is concluded that increasing concrete cover, the addition of fibers, considering transverse confinement, using deformed rebar instead of a plain one, using a concrete mixture with a lower value of w/c ratio, and air-cooling regime alleviate the detrimental influence of high-temperature exposure on the residual bond strength. Standing time can significantly recover the bond reduction as a healing period. Additionally, research gaps and the current conflicting results regarding some variables are drawn to be considered for future works.
引用
收藏
页码:370 / 410
页数:41
相关论文
共 50 条
  • [31] Bond strength and corrosion behavior of rebar embedded in copper slag concrete composites
    Panda, Swetapadma
    Alnounou, Mohammed A.
    Jawhara, Belal
    Sarkar, Pradip
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 416
  • [32] Bond performance of steel rebar embedded in 80-180 MPa ultra-high-strength concrete
    Yoo, Doo-Yeol
    Shin, Hyun-Oh
    CEMENT & CONCRETE COMPOSITES, 2018, 93 : 206 - 217
  • [33] Review of Post-Fire Inspection Procedures for Concrete Tunnels
    Menz, Nick
    Gerasimidis, Simos
    Civjan, Scott
    Czach, John
    Rigney, Joe
    TRANSPORTATION RESEARCH RECORD, 2021, 2675 (09) : 1304 - 1315
  • [34] Improvement of post-fire properties of concrete with steel slag aggregate
    Netinger, Ivanka
    Rukavina, Marija Jelcic
    Mladenovic, Ana
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 745 - 753
  • [35] Study on Sectional Nonuniform Corrosion and Bond Strength of Plain Rebar Embedded in Concrete
    Changming Li
    Li Song
    Fulai Qu
    Xiaoke Li
    Shunbo Zhao
    KSCE Journal of Civil Engineering, 2021, 25 : 3031 - 3040
  • [36] Post-fire behavior of steel slag fine aggregate concrete
    Zhuang, Xin
    Liang, Yi
    Ho, Johnny Ching Ming
    Wang, Yu-Hang
    Lai, Mianheng
    Li, Xuanyang
    Xu, Zhenhai
    Xu, Yuning
    STRUCTURAL CONCRETE, 2022, 23 (06) : 3672 - 3695
  • [37] Effects of post-fire curing conditions on the restoration of material properties of fire-damaged concrete
    Park, Sun-Jong
    Yim, Hong Jae
    Kwak, Hyo-Gyoung
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 99 : 90 - 98
  • [38] Effect of Corrosion on Bond Behavior of Rebar Embedded in Steel Fiber Reinforced Concrete
    Zhou B.
    Hou L.
    Guo S.
    Chen D.
    Ouyang F.
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2019, 22 (04): : 545 - 552
  • [39] Post-fire bond-slip performance of concrete-filled stainless steel tube columns
    He, Kang
    Chen, Yu
    Tang, Jiajun
    Li, Xin
    THIN-WALLED STRUCTURES, 2024, 204
  • [40] Post-fire performance of steel reinforced concrete columns with different steel sections
    Hassani, Meisam
    Safi, Mohammad
    Ardakani, Reza Rasti
    Daryan, Amir Saedi
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (16) : 3724 - 3738