Using a Traction Table for Fracture Reduction during Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Femoral Fractures Provides Anatomical Alignment

被引:4
|
作者
Paulsson, Martin [1 ,2 ]
Ekholm, Carl [1 ,2 ]
Tranberg, Roy [1 ,2 ]
Rolfson, Ola [1 ,2 ]
Geijer, Mats [3 ,4 ,5 ]
机构
[1] Sahlgrens Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Orthopaed, S-41345 Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Radiol, S-41345 Gothenburg, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiol, S-41345 Gothenburg, Sweden
[5] Lund Univ, Dept Clin Sci, S-22185 Lund, Sweden
关键词
femur fracture; orthopedic surgical procedure; fracture osteosynthesis; fracture fixation; internal; minimally invasive surgical procedure; operating table; bone misalignment; CORTICAL LOCKING SCREWS; FEMUR FRACTURES; STABILIZATION SYSTEM; INTERNAL-FIXATION; MALALIGNMENT; COMPLICATIONS; MALROTATION; FAILURE; NAILS;
D O I
10.3390/jcm12124044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Fracture reduction and fixation of distal femur fractures are technically demanding. Postoperative malalignment is still commonly reported after minimally invasive plate osteosynthesis (MIPO). We evaluated the postoperative alignment after MIPO using a traction table with a dedicated femoral support. Methods: The study included 32 patients aged 65 years or older with distal femur fractures of all AO/OTA types 32 (c) and 33 (except 33 B3 and C3) and peri-implant fractures with stable implants. Internal fixation was achieved with MIPO using a bridge-plating construct. Bilateral computed tomography (CT) scans of the entire femur were performed postoperatively, and measurements of the uninjured contralateral side defined anatomical alignment. Due to incomplete CT scans or excessively distorted femoral anatomy, seven patients were excluded from analyses. Results: Fracture reduction and fixation on the traction table provided excellent postoperative alignment. Only one of the 25 patients had a rotational malalignment of more than 15 & DEG; (18 & DEG;). Conclusions: The surgical setup for MIPO of distal femur fractures on a traction table with a dedicated femoral support facilitated reduction and fixation, resulting in a low rate of postoperative malalignment, despite a high rate of peri-implant fractures, and could be recommended for surgical treatment of distal femur fractures.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Medial Knee Approach: An Anatomical Study of Minimally Invasive Plate Osteosynthesis in Medial Femoral Condylar Fracture
    Sirisreetreerux, Norachart
    Shafiq, Babar
    Osgood, Greg M.
    Hasenboehler, Erik A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : e357 - e361
  • [42] Minimally Invasive Plate Osteosynthesis with Locking Plates for Distal Tibia Fractures
    Dhakar, Ajeet
    Annappa, Rajendra
    Gupta, Mahesh
    Harshwardhan, Hemeshwar
    Kotian, Prem
    Suresh, Pooja K.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (03) : RC1 - RC4
  • [43] Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures
    T. W. Lau
    F. Leung
    C. F. Chan
    S. P. Chow
    International Orthopaedics, 2008, 32
  • [44] Comparison between Intramedullary Nailing (IMN) and Minimally Invasive Plate Osteosynthesis (MIPO) Technique in Distal Tibia Fractures in Term of Union
    Imran, Muhammad
    Ishaq, Mohammad
    Kakar, Lal Mohammad Khan
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (04): : 1441 - 1444
  • [45] Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures
    Kundangar R.S.
    Mohanty S.P.
    Bhat N.S.
    MUSCULOSKELETAL SURGERY, 2019, 103 (2) : 191 - 197
  • [46] The Risk of Neurovascular Injury in Minimally Invasive Plate Osteosynthesis (MIPO) when Using a Distal Tibia Anterolateral Plate: A Cadaver Study
    Lidder, S.
    Masterson, S.
    Grechenig, C.
    Clement, H.
    Gaensslen, A.
    Grechenig, S.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2014, 81 (05) : 313 - 316
  • [47] MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS (MIPO) IN HUMERAL SHAFT FRACTURES - BIOMECHANICS - DESIGN - CLINICAL RESULTS
    Sanjeevaiah
    Reddy, Praneeth
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (54): : 9449 - 9456
  • [48] Minimally invasive plate osteosynthesis using the oblong hole of a locking plate for comminuted distal fibular fractures
    Young Uk Park
    Sung Jae Kim
    Hyong Nyun Kim
    Journal of Orthopaedic Surgery and Research, 16
  • [49] Evaluation of the Results of Minimally invasive Plate Osteosynthesis Using a Locking Plate in the Treatment of Distal Femur Fractures
    Abdelmonem, Abdelmonem H.
    Saber, Ahmed Y.
    El Sagheir, Mohamed
    El-Malky, Awad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [50] Minimally invasive plate osteosynthesis using the oblong hole of a locking plate for comminuted distal fibular fractures
    Park, Young Uk
    Kim, Sung Jae
    Kim, Hyong Nyun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01) : 281