Using a Traction Table for Fracture Reduction during Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Femoral Fractures Provides Anatomical Alignment

被引:4
|
作者
Paulsson, Martin [1 ,2 ]
Ekholm, Carl [1 ,2 ]
Tranberg, Roy [1 ,2 ]
Rolfson, Ola [1 ,2 ]
Geijer, Mats [3 ,4 ,5 ]
机构
[1] Sahlgrens Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Orthopaed, S-41345 Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Radiol, S-41345 Gothenburg, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiol, S-41345 Gothenburg, Sweden
[5] Lund Univ, Dept Clin Sci, S-22185 Lund, Sweden
关键词
femur fracture; orthopedic surgical procedure; fracture osteosynthesis; fracture fixation; internal; minimally invasive surgical procedure; operating table; bone misalignment; CORTICAL LOCKING SCREWS; FEMUR FRACTURES; STABILIZATION SYSTEM; INTERNAL-FIXATION; MALALIGNMENT; COMPLICATIONS; MALROTATION; FAILURE; NAILS;
D O I
10.3390/jcm12124044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Fracture reduction and fixation of distal femur fractures are technically demanding. Postoperative malalignment is still commonly reported after minimally invasive plate osteosynthesis (MIPO). We evaluated the postoperative alignment after MIPO using a traction table with a dedicated femoral support. Methods: The study included 32 patients aged 65 years or older with distal femur fractures of all AO/OTA types 32 (c) and 33 (except 33 B3 and C3) and peri-implant fractures with stable implants. Internal fixation was achieved with MIPO using a bridge-plating construct. Bilateral computed tomography (CT) scans of the entire femur were performed postoperatively, and measurements of the uninjured contralateral side defined anatomical alignment. Due to incomplete CT scans or excessively distorted femoral anatomy, seven patients were excluded from analyses. Results: Fracture reduction and fixation on the traction table provided excellent postoperative alignment. Only one of the 25 patients had a rotational malalignment of more than 15 & DEG; (18 & DEG;). Conclusions: The surgical setup for MIPO of distal femur fractures on a traction table with a dedicated femoral support facilitated reduction and fixation, resulting in a low rate of postoperative malalignment, despite a high rate of peri-implant fractures, and could be recommended for surgical treatment of distal femur fractures.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Minimally invasive plate osteosynthesis (MIPO) in proximal and distal fractures of the tibia
    Sirbu, P. D.
    Mihaila, R. I.
    Ghionoiu, G.
    Bruja, R.
    Asaftei, R.
    PROCEEDINGS OF THE 7TH EUROPEAN TRAUMA CONGRESS, 2006, : 349 - +
  • [2] Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Tibial Fracture Using a Posterolateral Approach
    Kritsaneephaiboon, Apipop
    Tangtrakulwanich, Boonsin
    Dissaneewate, Pornpanit
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2015, 14 (03): : 139 - 145
  • [3] Outcome of Minimally Invasive Plate Osteosynthesis for Distal Femoral Fractures
    Iqbal, Tariq
    Mughal, Naeem Mahmood
    Shahwani, Muhammad Bakhsh
    Dar, Usman Farooq
    Imtiaz, Umar
    Dar, Umar Farooq
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 492 - 494
  • [4] Minimally invasive plate osteosynthesis (MIPO) for scapular fractures
    van de Wall, B. J. M.
    Hoepelman, R. J.
    Michelitsch, C.
    Diwersi, N.
    Sommer, C.
    Babst, R.
    Beeres, F. J. P.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (06): : 390 - 396
  • [5] Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach
    Gupta, P.
    Tiwari, A.
    Thora, A.
    Gandhi, J. K.
    Jog, V. P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2016, 10 (01) : 29 - 37
  • [6] Femoral fractures treated by minimally invasive plate osteosynthesis (MIPO) in patients with abdominal injuries
    Cicvaric, T.
    Stalekar, H.
    Ekl, D.
    Sustic, A.
    Marinovic, M.
    PROCEEDINGS OF THE 7TH EUROPEAN TRAUMA CONGRESS, 2006, : 93 - +
  • [7] Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures
    Kim, Joon-Woo
    Oh, Chang-Wug
    Oh, Jong-Keon
    Park, Il-Hyung
    Kyung, Hee-Soo
    Park, Kyeong-Hyeon
    Yoon, Seong-Dae
    Kim, Seong-Min
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (03): : 751 - 757
  • [8] Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures
    Krettek, C
    Schandelmaier, P
    Miclau, T
    Tscherne, H
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 : SA20 - SA30
  • [9] Minimally invasive plate osteosynthesis (MIPO) for distal humeral fractures: a cadaveric study and first clinical application
    Hofmann, Valeska
    Diepold, Julian
    Moursy, Mohamed
    Birke, Marco T. T.
    Deininger, Christian
    Wichlas, Florian
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [10] Minimally Invasive Plate Osteosynthesis (Mipo) With DCS In Subtrochanteric Femoral Fractures. Is Still A Reasonable Option?
    Dan, Sirbu Paul
    Razvan, Asaftei
    Tudor, Petreus
    Grigore, Berea
    Rares, Sova
    Razvan, Tudor
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,