Transformer; paper insulation; aging state estimation; linear regression; FURFURAL ANALYSIS; POWER; METHANOL;
D O I
10.3233/ATDE231078
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aging state of transformer insulation papers was not assessed accurately. In this paper, multi-feature comprehensive assessment method was proposed to convert the nonlinear problem into a linear problem fitting for assessing the aging state of insulation papers. The whole aging process was divided into two stages with the degree of polymerization of 500 as the dividing point. The backward multiple linear regression analysis model was established and the error of the fitting results was analyzed. Most of the relative assessment errors were within +/- 5 %. It compensated for the deficiency of aging assessment of transformer insulation paper based on single feature, and the accuracy of assessment results was improved.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [41] An Approach to Aging Assessment of Power Transformer Based on Multi-parameters
    Li, Yuan
    Tang, Ming-jie
    Deng, Jun-bo
    Zhang, Guan-jun
    Wang, Shu-hong
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 357 - 360
  • [42] Ageing Assessment of Transformer Paper Insulation through Detection of Methanol in Oil
    Matharage, S. Y.
    Liu, Q.
    Wang, Z. D.
    Mavrommatis, P.
    Wilson, G.
    Jarman, P.
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 392 - 395
  • [43] Ageing Assessment of Transformer Paper Insulation through Post Mortem Analysis
    Azis, N.
    Liu, Q.
    Wang, Z. D.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) : 845 - 853
  • [44] Research on Fatigue Driving State Recognition Method Based on Multi-feature Fusion
    Hu F.
    Cheng Z.
    Xu Q.
    Peng Q.
    Quan X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (04): : 100 - 107
  • [45] Aging State Evaluation for Insulation Paper of Traction Transformer Hotspot Region Based on FDS and Intelligent Algorithm
    Gong, Heyan
    Jiang, Zaijun
    Liu, Jiefeng
    Fan, Xianhao
    Wu, Thomas
    Li, Chuanyang
    Mazzanti, Giovanni
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2025, 11 (01): : 4350 - 4358
  • [46] A power transformer insulation condition assessment method based on set pair analysis
    Liao, Ruijin
    Zheng, Hanbo
    Yang, Lijun
    Zhang, Yiyi
    Huang, Feilong
    Sun, Caixin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (21): : 55 - 60
  • [47] Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method
    J. Liu
    X. Fan
    H. Zheng
    Y. Zhang
    C. Zhang
    B. Lai
    J. Wang
    G. Ren
    E. Zhang
    Cellulose, 2019, 26 : 3891 - 3908
  • [49] Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method
    Liu, J.
    Fan, X.
    Zheng, H.
    Zhang, Y.
    Zhang, C.
    Lai, B.
    Wang, J.
    Ren, G.
    Zhang, E.
    CELLULOSE, 2019, 26 (06) : 3891 - 3908
  • [50] Dielectric Response Evaluation Method for Multi-factor Aging of Converter Transformer Oil-paper Insulation
    Liu, Ji
    Cheng, Weichao
    Zhang, Mingze
    Ma, Xingming
    Jia, Haifeng
    Zhuang, Weitao
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (05): : 1684 - 1694