Fluorescent Aptasensor for Determination of 8-Oxo-2?- deoxyguanosine in Urine Using Carbon Dots and Amine- Functionalized Gold Nanoparticles

被引:1
|
作者
Ngernpimai, Sawinee [1 ,2 ]
Thonghlueng, Janpen [3 ]
Phothikul, Yaowaret [1 ]
Chompoosor, Apiwat [4 ]
Thanan, Raynoo [1 ]
Puangmali, Theerapong [3 ]
Sakonsinsiri, Chadamas [1 ]
机构
[1] Khon Kaen Univ, Fac Med, Dept Biochem, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Associated Med Sci, Ctr Innovat & Stand Med Technol & Phys Therapy, Khon Kaen 40002, Thailand
[3] Khon Kaen Univ, Fac Sci, Dept Phys, Khon Kaen 40002, Thailand
[4] Ramkhamhang Univ, Fac Sci, Dept Chem, Bangkok 10240, Thailand
关键词
8-oxo-dG; fluorescence; gold nanoparticle; carbon dot; aptasensor; OXIDATIVE STRESS; COLORIMETRIC DETECTION; DNA-DAMAGE; 8-HYDROXY-2'-DEOXYGUANOSINE; APTAMER; MECHANISM; DEVICE; ASSAY;
D O I
10.1021/acsanm.3c01238
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
8-Oxo-7,8-dihydro-2 '-deoxyguanosine (8-oxo-dG) is a crucial biomarker of oxidative DNA damage. Herein, a highly sensitive fluorescent aptasensor for detecting 8-oxo-dG in urine was developed based on aptamer-mediated quenching of amino-terminated oligo(ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) toward green emissive carbon dots (G -CDs). G-CDs were employed as fluorometric reporters. Upon addition of 8-oxo-dG, it formed a complex with an anti-8-oxo-dG aptamer, resulting in the quenching of fluorescence as NH2-TEG-AuNPs absorbed the emission from G-CDs. Initially, NH2-TEG-AuNPs suppressed the fluorescence intensity of G-CDs via the inner-filter effect (IFE). With the addition of the aptamers to a mixture of G-CDs and NH2-TEG-AuNPs, the electrostatic interactions between the aptamer and NH2-TEG-AuNPs resulted in the aggregation of NH2-TEG-AuNPs and the recovery of the fluorescence intensity of the quenched G-CDs. NH2-TEG-AuNPs dispersed due to the high affinity between the aptamer and 8-oxo-dG molecules, and the system demonstrated a fluorescence '' turn-off '' response of G-CDs. Thus, it was possible to determine the 8-oxo-dG concentration. A fluorescence calibration curve was constructed with two linear ranges: 100-2000 and 2000-10,000 nM. The limit of detection (LOD) for 8-oxo-dG was 15.89 nM. This approach was successfully applied to assess 8-oxo-dG in synthetic urine samples with mean recoveries ranging from 99 to 120% and relative standard deviations (RSDs) between 1.1 and 4.1%. The analytical performance was comparable to a commercially available enzyme-linked immunosorbent assay (ELISA) kit. This proposed fluorescent aptasensor for 8-oxo-dG detection in urine exhibited high selectivity and sensitivity over a broad concentration range against the target molecule and has the potential to be developed as a new platform for rapid screening of 8-oxo-dG.
引用
收藏
页码:7055 / 7064
页数:10
相关论文
共 50 条
  • [31] Sensitive Fluorescent Determination of Matrix Metalloproteinase-2 (MMP-2) Using the Inner Filter Effect (IFE) with Carbon Dots and Aggregated Gold Nanoparticles
    Sun, Dapeng
    Ye, Chenglong
    Chen, Zhuo
    ANALYTICAL LETTERS, 2024,
  • [32] Aptamer-based fluorometric determination for mucin 1 using gold nanoparticles and carbon dots
    Wang, Weiwei
    Wang, Yan
    Pan, Hong
    Cheddah, Soumia
    Yan, Chao
    MICROCHIMICA ACTA, 2019, 186 (08)
  • [33] Colorimetric and turn-on fluorescence determination of mercury (II) by using carbon dots and gold nanoparticles
    Lu, Changfang
    Ding, Hao
    Wang, Yutong
    Xiong, Chaoying
    Wang, Xianxiang
    NANOTECHNOLOGY, 2021, 32 (15)
  • [34] Aptamer-based fluorometric determination for mucin 1 using gold nanoparticles and carbon dots
    Weiwei Wang
    Yan Wang
    Hong Pan
    Soumia Cheddah
    Chao Yan
    Microchimica Acta, 2019, 186
  • [35] Ultra-sensitive Simultaneous Determination of 8-oxo-7,8-dihydro-2′-deoxyguanosine, 1, N2-etheno-2′-deoxyguanosine and 1, N2-propano-2′-deoxyguanosine in Human Urine
    Garcia, Camila Carriao M.
    Freitas, Florencio Porto
    Gomes, Osmar Francisco
    Di Mascio, Paolo
    Medeiros, Marisa H. G.
    FREE RADICAL BIOLOGY AND MEDICINE, 2009, 47 : S75 - S75
  • [36] Electrochemical Determination of 8-Nitroguanine and 8-Hydroxy-2`-Deoxyguanosine in Urine and Whole Blood Using Stochastic Sensors
    Stefan-van Staden, Raluca-Ioana
    Balahura, Liliana-Roxana
    Aboul-Enein, Hassan Y.
    ANALYTICAL LETTERS, 2021, 54 (04) : 729 - 741
  • [37] Accumulation of 8-oxo-2′-deoxyguanosine (as a biomarker of oxidative DNA damage) in the tissues of aged hamsters and change in antioxidant enzyme activities after single administration of N-nitrosobis(2-oxopropyl)amine
    Takabayashi, F
    Tahara, S
    Kaneko, T
    Miyoshi, Y
    Harada, N
    GERONTOLOGY, 2004, 50 (02) : 57 - 63
  • [38] An inner filter effect-based fluorescent aptasensor for sensitive detection of kanamycin in complex samples using gold nanoparticles and graphene oxide quantum dots
    Li, Mengyan
    Huang, Ruoying
    Liao, Xiaofei
    Zhou, Zidan
    Zou, Li
    Liu, Bing
    ANALYTICAL METHODS, 2023, 15 (06) : 843 - 848
  • [39] Electrochemical Sensor Platform for 8-Hydroxy-2′Deoxyguanosine Detection Based on Carboxyl-Functionalized Carbon-Allotropic Nanomaterials Wrapped Gold Nanoparticles Modified Electrode
    Yi, Zhengjun
    Qiao, Jinjuan
    Wang, Ying
    Gao, Kunshan
    Zhao, Ronglan
    Meng, Xiangying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9098 - 9111
  • [40] Determination of lead(II) in food samples using a functionalized paper-based fluorescent sensor modified by carbon dots
    Aboobakri, Elias
    Heidari, Tahereh
    Jahani, Moslem
    LUMINESCENCE, 2024, 39 (02)