Improving Detection Efficiency of Silicon Carbide Neutron Detector Using Double Trench

被引:6
|
作者
Zhang, Lilong [1 ]
Wang, Ying [1 ]
Guo, Haomin [1 ]
Hu, Haifan [2 ]
Liu, Yuntao [3 ]
Chen, Size [4 ]
机构
[1] Hangzhou Dianzi Univ, Sch Elect & Informat, Hangzhou 310018, Peoples R China
[2] Aerosp Sci & Technol Corp, Inst China 2, Lab 10, Beijing 100854, Peoples R China
[3] Harbin Engn Univ, Coll Informat & Commun Engn, Harbin 150001, Peoples R China
[4] Chinese Acad Sci, Inst Nucl Energy Safety Technol, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
关键词
Neutrons; Silicon carbide; Detectors; Solids; Electrodes; Solid modeling; Sensors; Detection efficiency; double trench; energy deposition; silicon carbide (SiC) neutron detectors; P-TYPE; OHMIC CONTACTS; RADIATION HARDNESS; DETECTION SYSTEM; N-TYPE; SEMICONDUCTOR; DESIGN; PERFORMANCE; DIODE; FILM;
D O I
10.1109/JSEN.2023.3238164
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we propose a double-trench-type silicon carbide (SiC) neutron detector and model it using the concept of a unit cell on the GEANT4 platform. When the low-level discriminator (LLD) value was fixed at 300 keV, the structural parameters of this double-trench-type SiC neutron detector were optimized to maximize the intrinsic detection efficiency. Compared with the single trench type, the double-trench-type SiC neutron detector can significantly improve the neutron intrinsic detection efficiency within a limited trench depth, which was especially suitable for the current technological status that SiC materials can only be used for shallow trench etching. Apart from optimizing the structural parameters, the energy deposition spectra in the SiC detector region by the generated secondary charged particles upon thermal neutron interaction in neutron conversion materials (B-10 and 6LiF) have also been estimated. It can be found that the double-trench-type SiC neutron detector counts significantly increased in the low-energy range, while the counts in the high-energy range are only slightly decreased. This is also the essential reason why the intrinsic detection efficiency of the double-trench-type SiC neutron detector was significantly improved compared to the single-trench-type SiC neutron detector.
引用
收藏
页码:4302 / 4310
页数:9
相关论文
共 50 条
  • [21] TCAD assisted analysis of Silicon Carbide based Fast Neutron Detector for nuclear applications
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Devan, K.
    Venkatesan, A.
    Panigrahi, B. K.
    2017 IEEE 12TH NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (NMDC), 2017, : 190 - 191
  • [22] Microstructure Boron Detector for High Efficiency Thermal Neutron Detection
    Fujiwara, T.
    Takahashi, H.
    Yamada, N. L.
    Uesaka, M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [23] DETECTION EFFICIENCY OF THE NEUTRON MODULAR DETECTOR DEMON AND RELATED CHARACTERISTICS
    TILQUIN, I
    ELMASRI, Y
    PARLOG, M
    COLLON, P
    HADRI, M
    KEUTGEN, T
    LEHMANN, J
    LELEUX, P
    LIPNIK, P
    NINANE, A
    HANAPPE, F
    BIZARD, G
    DURAND, D
    MOSRIN, P
    PETER, J
    REGIMBART, R
    TAMAIN, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 446 - 461
  • [24] Improving thermal-neutron detection efficiency of silicon neutron detectors using the combined layers of 10B4C on 6LiF
    Jiang, Yong
    Wu, Jian
    Yin, Yanpeng
    Lu, Yi
    Wu, Kunlin
    Fan, Xiaoqiang
    Lei, Jiarong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 932 : 50 - 55
  • [25] Thermal neutron detection using a silicon pad detector and 6LiF removable converters
    Barbagallo, Massimo
    Cosentino, Luigi
    Forcina, Vittorio
    Marchetta, Carmelo
    Pappalardo, Alfio
    Peerani, Paolo
    Scire, Carlotta
    Scire, Sergio
    Schillaci, Maria
    Vaccaro, Stefano
    Vecchio, Gianfranco
    Finocchiaro, Paolo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (03):
  • [26] On neutron detection with silicon carbide and its resistance to large accumulated fluence
    R. Bedogni
    A. Calamida
    A. I. Castro Campoy
    A. Fontanilla
    J. M. Gomez-Ros
    V. Monti
    E. Mafucci
    N. Protti
    S. Altieri
    A. Pietropaolo
    The European Physical Journal Plus, 137
  • [27] On neutron detection with silicon carbide and its resistance to large accumulated fluence
    Bedogni, R.
    Calamida, A.
    Castro Campoy, A. I.
    Fontanilla, A.
    Gomez-Ros, J. M.
    Monti, V.
    Mafucci, E.
    Protti, N.
    Altieri, S.
    Pietropaolo, A.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (12):
  • [28] Detection efficiency of a new type of solar neutron detector calibrated by an accelerator neutron beam
    Tsuchiya, H
    Muraki, Y
    Masuda, K
    Matsubara, Y
    Koi, T
    Sako, T
    Ohno, S
    Hoshida, T
    Shibata, S
    Munakata, Y
    Hatanaka, K
    Wakasa, T
    Sakai, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 183 - 193
  • [29] Improving the Properties of Dental Porcelain Luminescence Using Silicon Carbide
    Norouzi, Nima
    Nouri, Zahra
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2021, 11 (03): : 11023 - 11030
  • [30] Monte-carlo calculation of the neutron detection efficiency of a foil detector
    Park, S
    Kim, YK
    Ha, JH
    Kim, JK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (04) : 586 - 591