Impedance-Based Short Circuit-Short Circuit Fault Location Method in Coaxial Cables

被引:1
|
作者
Bugajska, Aneta [1 ]
Desaniuk, Tomasz [2 ]
机构
[1] Kielce Univ Technol, Fac Elect Engn Automat Control & Comp Sci, PL-25314 Kielce, Poland
[2] Kielce Univ Technol, Fac Mechatron & Mech Engn, PL-25314 Kielce, Poland
关键词
Input impedance; transverse impedance; distance to the fault location; coaxial cable; diagnostic tests; SCHEME; WAVE;
D O I
10.1109/ACCESS.2023.3320641
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper presents the results of the assessment and verification of a non-destructive method of fault location in coaxial cables with a local weakening of insulation. The essence of the method is to measure the input impedance of the cable in a short circuit at both ends and, based on obtained values, to determine the transverse impedance of the fault and the distance to the fault location. For the RG59 Cable with a length of 50.0 m, with the assumed distance to the fault location of 5.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 1.8 m, for open circuit-open circuit from 0.1 m to 0.2 m and open circuit-short circuit to 0.2 m. For the RG59 Cable at the actual distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 0.7 m, for open circuit-open circuit from 0.0 m to 0.1 m and open circuit-short circuit from 0.2 m to 0.7 m. For the RF-7 Cable with a length of 100.0 m, with the assumed distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.7 m to 1.8 m, for open circuit-open circuit from 0.0 m to 0.7 m and open circuit-short circuit 0.2 m to 2.3 m. For the RF-7 Cable with the assumed distance to the fault location of 20.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.1 m to 1.2 m, for open circuit-open circuit method from 0.1 m to 0.3 m and open circuit-short circuit method from 0.1 m to 0.7 m.
引用
收藏
页码:115231 / 115279
页数:49
相关论文
共 50 条
  • [41] A circuit design for impedance-based structural health monitoring
    Wang, Shirui
    You, Chao
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2008, 19 (09) : 1029 - 1040
  • [42] SHORT CIRCUIT CAPACITIES OF CABLES WITH SOLID INSULATION.
    Anon
    Electrical India, 1987, 27 (12): : 19 - 20
  • [43] SHORT-CIRCUIT CAPACITY OF TEMPORARY GROUNDING CABLES
    REICHMAN, J
    VAINBERG, M
    KUFFEL, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 260 - 271
  • [44] Fault Location Method Using Phasor Measurement Units and Short Circuit Analysis for Power Distribution Networks
    Hong, Ji-Song
    Sim, Gi-Do
    Choi, Joon-Ho
    Ahn, Seon-Ju
    Yun, Sang-Yun
    ENERGIES, 2020, 13 (05)
  • [45] NEW EQUIVALENT CIRCUIT FOR IMPEDANCE OF SHORT RADIATORS
    LANDSTORFER, F
    MEINKE, HH
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1973, 26 (11): : 490 - 495
  • [46] Research on Autotransformer Short-circuit Impedance
    Wang, Huan
    Li, Yan
    2017 5TH INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN, MANUFACTURING, MODELING AND SIMULATION (CDMMS 2017), 2017, 1834
  • [47] SHORT-CIRCUIT CURRENTS CALCULATION BY USING THE IMPEDANCE CORRECTION METHOD
    SCHAEFER, W
    ETZ ARCHIV, 1985, 7 (01): : 25 - 31
  • [48] Impedance-Based Fault Location Analysis for Transmission Lines
    de Andrade, L.
    Ponce de Leao, T.
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [49] Fault coil location approach of permanent magnet synchronous motor with interturn short circuit fault
    Chen H.
    Zhang N.
    Gao C.-X.
    Sang X.-C.
    Xu X.-Z.
    Feng H.-C.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (03): : 124 - 134
  • [50] A battery internal short circuit fault diagnosis method based on incremental capacity curves
    Sun, Jinlei
    Chen, Siwen
    Xing, Shiyou
    Guo, Yilong
    Wang, Shuhang
    Wang, Ruoyu
    Wu, Yuhao
    Wu, Xiaogang
    JOURNAL OF POWER SOURCES, 2024, 602