Exergy analysis of heat pump air conditioning systems for pure electric vehicle use with low-GWP refrigerants

被引:7
|
作者
Lei, Shurong [1 ]
Guo, Bin [1 ]
Zhao, Ziliang [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Transportat, Qingdao 266590, Peoples R China
关键词
Pure electric vehicle; Heat pump air conditioning; Low-GWP refrigerant; Exergy analysis; PERFORMANCE EVALUATION; AUTOMOBILE AIR; R134A; ENERGY; R1234YF; R152A; R744;
D O I
10.1016/j.ijrefrig.2023.10.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
The exergy analysis of low-global warming potential (GWP) alternative refrigerants, R1234yf, R152a and R744 for heat pump air conditioning (HPAC) systems used in pure electric vehicles (EVs) is conducted via simulation. The results reveal that the system exergy efficiencies (SEEs) of R1234yf-HPAC and R152a-HPAC under identical cooling or heating capacity are similar due to their close thermodynamic properties. The largest exergy destruction component in R1234yf- and R152a-HPACs is the compressor. While for R744-HPAC, the compressor and expansion valve cause major exergy destruction. Moreover, the results also indicate that the SEE of R744HPAC is at least 20 % lower than that of R1234yf-HPAC when producing identical cooling capacity, while it is on average twice that of R1234-HPAC when producing identical heating capacity. Furthermore, the measures to improve SEE of HPAC systems with different refrigerants are discussed by examining the effects of varying operating conditions. It is suggested to lower compressor speed under both cooling and heating conditions, increase condenser airflow or reduce evaporator airflow of R1234yf-, R152a- and R744-HPACs under cooling condition; for cabin heating, it is advisable to increase the evaporator airflow or decrease condenser airflow for R1234yf- and R152a- HPACs and enlarge condenser airflow for R744-HPAC to elevate SEE.
引用
收藏
页码:266 / 277
页数:12
相关论文
共 50 条
  • [21] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    Zhang Kexin
    Li Ming
    Yang Changhai
    Shao Zhiyuan
    Wang Lihong
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (02) : 408 - 422
  • [22] Heating Performance Characteristics of an Electric Vehicle Heat Pump Air Conditioning System Based on Exergy Analysis
    Tang, Xingwang
    Guo, Qin
    Li, Ming
    Jiang, Mingzhe
    ENERGIES, 2020, 13 (11)
  • [23] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    ZHANG Kexin
    LI Ming
    YANG Changhai
    SHAO Zhiyuan
    WANG Lihong
    JournalofThermalScience, 2020, 29 (02) : 408 - 422
  • [24] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    Kexin Zhang
    Ming Li
    Changhai Yang
    Zhiyuan Shao
    Lihong Wang
    Journal of Thermal Science, 2020, 29 : 408 - 422
  • [25] Comparison of the flow characteristics and performance of low-GWP refrigerants in expansion capillary used in air conditioning units
    Barbhuiya, S. H.
    Prasad, K.
    Kruthiventi, S. S. H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2025, 22 (01) : 205 - 218
  • [26] Heating performance of heat pump air conditioning system for battery electric vehicle with different refrigerants
    Lv, Ran
    Li, Zhijun
    Wang, Yiming
    Li, Ming
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2024, 238 (04) : 702 - 718
  • [27] Barriers to the Use of Low GWP Refrigerants in the Refrigeration and Air Conditioning Sector in Mauritius
    Dreepaul, R. K.
    Elahee, K.
    2018 5TH INTERNATIONAL SYMPOSIUM ON ENVIRONMENT-FRIENDLY ENERGIES AND APPLICATIONS (EFEA), 2018,
  • [28] Performance analysis of electric vehicle heat pump air conditioning system
    Li, Ming
    Xue, Qing-Feng
    Zhang, Ke-Xin
    Lyu, Ran
    Wei, Chang-Hua
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2021, 51 (06): : 1943 - 1952
  • [29] Seasonal performance assessment of refrigerants with low GWP as substitutes for R410A in heat pump air conditioning devices
    Devecioglu, Atilla Gencer
    APPLIED THERMAL ENGINEERING, 2017, 125 : 401 - 411
  • [30] The influence of internal heat exchanger on energy efficiency and environmental effects of the Heat Pump using Low-GWP Refrigerants as substitutes
    Zhao Yuqing
    Dai Yun
    Gaoyan
    Xie Lanyi
    Hou Xiangyang
    Gao Jianling
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186