A dual-emission ratiometric fluorescent biosensor for ultrasensitive detection of glibenclamide using S-CDs/CdS quantum dots

被引:4
|
作者
Gazizadeh, Masoud [1 ]
Dehghan, Gholamreza [1 ]
Soleymani, Jafar [2 ]
机构
[1] Univ Tabriz, Fac Nat Sci, Dept Biol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
关键词
Diabetes mellitus; Sulfide-doped carbon dots; Cadmium sulfide quantum dots; Glibenclamide; Ratiometric fluorescence; MOLECULARLY IMPRINTED POLYMER; METFORMIN HYDROCHLORIDE; CARBON DOTS; NANOPARTICLES; VALIDATION; GLICLAZIDE; PLATFORM; CANCER; PLASMA; SENSOR;
D O I
10.1016/j.saa.2023.122714
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present work, sulfide-doped carbon dots (S-CDs)/cadmium sulfide quantum dots (CdS QDs) ratiometric fluorescent nanosensor has been developed for sensitive and selective determination of glibenclamide (GLC) in biological fluids. The method was based on the quenching effect of GLC on the dual-emission intensity of the SCDs/CdS QDs system at 420 nm and 650 nm, which are related to S-CDs and CdS QDs, respectively. The fluorimetric data analysis indicated that the fluorescence signals of the system were quenched by adding GLC in a concentration-dependent manner. A good linear relationship was observed between GLC concentration and the quenched fluorescence intensity of the S-CDs/CdS QDs in the range of 0.3 nM-10.0 & mu;M. The limit of detection (LOD) value was estimated to be 0.12 nM. Furthermore, under optimum conditions, GLC was detected in spiked human serum sample (as real media) using the developed ratiometric nanosensor with an accuracy of 99.6%. According to the results, the developed dual-emission system can be used as a reliable method for the quantitative detection of GLC in biological samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Determination of cyanide based on a dual-emission ratiometric nanoprobe using silver sulfide quantum dots and silicon nanoparticles
    Fatemeh Rahimi
    Mansoor Anbia
    Microchimica Acta, 2022, 189
  • [32] Development of N,S-CDs fluorescent probe method for early detection of Cr(VI) in the environment
    Feni R. M. Diana
    Adhitasari Suratman
    Endang T. Wahyuni
    Mudasir Mudasir
    Suherman Suherman
    Chemical Papers, 2022, 76 : 7793 - 7809
  • [33] Electrochemiluminescent immunosensor based on CdS quantum dots for ultrasensitive detection of microcystin-LR
    Zhang, Jing-Jing
    Kang, Tian-Fang
    Hao, Yu-Cui
    Lu, Li-Ping
    Cheng, Shui-Yuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 214 : 117 - 123
  • [34] Dual-emission carbon dots based ratiometric fluorescent sensor with opposite response for detecting copper (II)
    Huang, Gengli
    Luo, Xueli
    He, Xie
    Han, Yong
    Zhao, Haiping
    Tang, Wenzhi
    Yue, Tianli
    Li, Zhonghong
    DYES AND PIGMENTS, 2021, 196
  • [35] Dual-Emission Carbon Dots for Ratiometric Fluorescent Water Sensing, Relative Humidity Sensing, and Anticounterfeiting Applications
    Qin, Yujuan
    Bai, Yongju
    Huang, Pengcheng
    Wu, Fang-Ying
    ACS APPLIED NANO MATERIALS, 2021, 4 (10) : 10674 - 10681
  • [36] Dual-emission of Eu based metal-organic frameworks hybrids with carbon dots for ratiometric fluorescent detection of Cr(VI)
    Wang, Yingying
    He, Jiang
    Zheng, Mingda
    Qin, Mingda
    Wei, Wei
    TALANTA, 2019, 191 : 519 - 525
  • [37] Carbon dots-based dual-emission ratiometric fluorescent sensors for fluorescence and visual detection of hypochlorite and Cu2+
    Guo, Beibei
    Wang, Dinghai
    Wang, Minhui
    Tang, Yecang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 318
  • [38] Mediator-free biosensor using chitosan capped CdS quantum dots for detection of total cholesterol
    Dhyani, Hemant
    Ali, Md. Azahar
    Pal, Satyendra P.
    Srivastava, Saurabh
    Solanki, Pratima R.
    Malhotra, Bansi D.
    Sen, Prasenjit
    RSC ADVANCES, 2015, 5 (57) : 45928 - 45934
  • [39] Fluorescence Resonance Energy Transfer-Based Ratiometric Fluorescent Probe for Detection of Zn2+ Using a Dual-Emission Silica-Coated Quantum Dots Mixture
    Wu, Liang
    Guo, Qing-Sheng
    Liu, Yu-Qian
    Sun, Qing-Jiang
    ANALYTICAL CHEMISTRY, 2015, 87 (10) : 5318 - 5323
  • [40] A novel dual-excitation and dual-emission fluorescent probe CDs-COO-F for hydrazine detection in aqueous solutions and living cells
    Liu, Wenfang
    Jia, Haishuang
    Zhang, Jie
    Shao, Ling
    Wang, Jun
    Fang, Dawei
    DYES AND PIGMENTS, 2021, 184