Diagnostic Performance of Dynamic Whole-Body Patlak [18F]FDG-PET/CT in Patients with Indeterminate Lung Lesions and Lymph Nodes

被引:2
|
作者
Weissinger, Matthias [1 ,2 ]
Atmanspacher, Max [1 ]
Spengler, Werner [3 ]
Seith, Ferdinand [2 ]
Von Beschwitz, Sebastian [1 ]
Dittmann, Helmut [1 ]
Zender, Lars [3 ]
Smith, Anne M. [4 ]
Casey, Michael E. [4 ]
Nikolaou, Konstantin [2 ,5 ,6 ]
Castaneda-Vega, Salvador [1 ,7 ]
la Fougere, Christian [1 ,5 ,6 ]
机构
[1] Univ Hosp Tuebingen, Dept Nucl Med & Clin Mol Imaging, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Internal Med 8, D-72076 Tubingen, Germany
[4] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN 37932 USA
[5] Eberhard Karls Univ Tuebingen, iFIT Cluster Excellence, D-72076 Tubingen, Germany
[6] German Canc Consortium DKTK, Partner Site Tuebingen, D-72076 Tubingen, Germany
[7] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, D-72076 Tubingen, Germany
关键词
whole-body; dynamic PET; parametric FDG; Patlak; FDG; PET; CT; BRAIN TRANSFER CONSTANTS; GRAPHICAL EVALUATION; CANCER;
D O I
10.3390/jcm12123942
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Static [F-18]FDG-PET/CT is the imaging method of choice for the evaluation of indeterminate lung lesions and NSCLC staging; however, histological confirmation of PET-positive lesions is needed in most cases due to its limited specificity. Therefore, we aimed to evaluate the diagnostic performance of additional dynamic whole-body PET. Methods: A total of 34 consecutive patients with indeterminate pulmonary lesions were enrolled in this prospective trial. All patients underwent static (60 min p.i.) and dynamic (0-60 min p.i.) whole-body [F-18]FDG-PET/CT (300 MBq) using the multi-bed-multi-timepoint technique (Siemens mCT FlowMotion). Histology and follow-up served as ground truth. Kinetic modeling factors were calculated using a two-compartment linear Patlak model (FDG influx rate constant = Ki, metabolic rate = MR-FDG, distribution volume = DV-FDG) and compared to SUV using ROC analysis. Results: MR-FDG(mean) provided the best discriminatory power between benign and malignant lung lesions with an AUC of 0.887. The AUC of DV-FDG(mean) (0.818) and SUVmean (0.827) was non-significantly lower. For LNM, the AUCs for MR-FDG(mean) (0.987) and SUVmean (0.993) were comparable. Moreover, the DV-FDG(mean) in liver metastases was three times higher than in bone or lung metastases. Conclusions: Metabolic rate quantification was shown to be a reliable method to detect malignant lung tumors, LNM, and distant metastases at least as accurately as the established SUV or dual-time-point PET scans.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Whole-body [18F]FDG PET in the management of metastatic brain tumours
    Kim, DG
    Kim, CY
    Paek, SH
    Lee, DS
    Chung, JK
    Jung, HW
    Cho, BK
    ACTA NEUROCHIRURGICA, 1998, 140 (07) : 665 - 673
  • [42] Detection of cancer-associated cachexia in lung cancer patients using whole-body [18F]FDG-PET/CT imaging: A multi-centre study
    Ferrara, Daria
    Abenavoli, Elisabetta M.
    Beyer, Thomas
    Gruenert, Stefan
    Hacker, Marcus
    Hesse, Swen
    Hofmann, Lukas
    Pusitz, Smilla
    Rullmann, Michael
    Sabri, Osama
    Sciagra, Roberto
    Sundar, Lalith Kumar Shiyam
    Toenjes, Anke
    Wirtz, Hubert
    Yu, Josef
    Frille, Armin
    JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2024, 15 (06) : 2375 - 2386
  • [43] Whole-Body [18F]FDG PET in the Management of Metastatic Brain Tumours
    D. G. Kim
    C.-Y. Kim
    S. H. Paek
    D. S. Lee
    J.-K. Chung
    H.-W. Jung
    B.-K. Cho
    Acta Neurochirurgica, 1998, 140 : 665 - 674
  • [44] Benign Colonic F-18-FDG Uptake on Whole-Body FDG-PET Scan
    Jang, Byung Ik
    CLINICAL ENDOSCOPY, 2012, 45 (02) : 109 - 110
  • [45] Meta-analysis of the diagnostic performance of [18F]FDG-PET and PET/CT in renal cell carcinoma
    Wang, Hsin-Yi
    Ding, Hueisch-Jy
    Chen, Jin-Hua
    Chao, Chih-Hao
    Lu, Yu-Yu
    Lin, Wan-Yu
    Kao, Chia-Hung
    CANCER IMAGING, 2012, 12 (03): : 464 - 474
  • [46] Simplified protocol for whole-body Patlak parametric imaging with 18F-FDG PET/CT: Feasibility and error analysis
    Yao, Shulin
    Feng, Tao
    Zhao, Yizhang
    Wu, Runze
    Wang, Ruimin
    Wu, Shina
    Li, Can
    Xu, Baixuan
    MEDICAL PHYSICS, 2021, 48 (05) : 2160 - 2169
  • [47] Detection of multiple extracranial metastases from glioblastoma multiforme by means of whole-body [18F]FDG-PET
    Mirzayan, MJ
    Samii, M
    Petrich, T
    Börner, AR
    Knapp, WH
    Samii, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (07) : 853 - 853
  • [48] Direct versus indirect parametric whole body [18F]FDG Patlak imaging using a LAFOV PET/CT system
    van Sluis, J.
    Providencia, L.
    van Snick, J. H.
    Glaudemans, A. W. J. M.
    Slart, R. H. J. A.
    Dierckx, R. A. J. O.
    Tsoumpas, C.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S160 - S160
  • [49] [18F]FDG-PET/CT patterns of bone metastases in lung cancer
    Perri, M.
    Volterrani, D.
    Erba, P.
    Lucchi, M.
    Mattone, V.
    Rizza, E.
    Pesella, F.
    Mariani, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S287 - S288
  • [50] Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone Lesions
    Eiber, Matthias
    Takei, Toshiki
    Souvatzoglou, Michael
    Mayerhoefer, Marius E.
    Fuerst, Sebastian
    Gaertner, Florian C.
    Loeffelbein, Denys J.
    Rummeny, Ernst J.
    Ziegler, Sibylle I.
    Schwaiger, Markus
    Beer, Ambros J.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 191 - 197