Diagnostic Performance of Dynamic Whole-Body Patlak [18F]FDG-PET/CT in Patients with Indeterminate Lung Lesions and Lymph Nodes

被引:2
|
作者
Weissinger, Matthias [1 ,2 ]
Atmanspacher, Max [1 ]
Spengler, Werner [3 ]
Seith, Ferdinand [2 ]
Von Beschwitz, Sebastian [1 ]
Dittmann, Helmut [1 ]
Zender, Lars [3 ]
Smith, Anne M. [4 ]
Casey, Michael E. [4 ]
Nikolaou, Konstantin [2 ,5 ,6 ]
Castaneda-Vega, Salvador [1 ,7 ]
la Fougere, Christian [1 ,5 ,6 ]
机构
[1] Univ Hosp Tuebingen, Dept Nucl Med & Clin Mol Imaging, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Internal Med 8, D-72076 Tubingen, Germany
[4] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN 37932 USA
[5] Eberhard Karls Univ Tuebingen, iFIT Cluster Excellence, D-72076 Tubingen, Germany
[6] German Canc Consortium DKTK, Partner Site Tuebingen, D-72076 Tubingen, Germany
[7] Eberhard Karls Univ Tuebingen, Werner Siemens Imaging Ctr, Dept Preclin Imaging & Radiopharm, D-72076 Tubingen, Germany
关键词
whole-body; dynamic PET; parametric FDG; Patlak; FDG; PET; CT; BRAIN TRANSFER CONSTANTS; GRAPHICAL EVALUATION; CANCER;
D O I
10.3390/jcm12123942
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Static [F-18]FDG-PET/CT is the imaging method of choice for the evaluation of indeterminate lung lesions and NSCLC staging; however, histological confirmation of PET-positive lesions is needed in most cases due to its limited specificity. Therefore, we aimed to evaluate the diagnostic performance of additional dynamic whole-body PET. Methods: A total of 34 consecutive patients with indeterminate pulmonary lesions were enrolled in this prospective trial. All patients underwent static (60 min p.i.) and dynamic (0-60 min p.i.) whole-body [F-18]FDG-PET/CT (300 MBq) using the multi-bed-multi-timepoint technique (Siemens mCT FlowMotion). Histology and follow-up served as ground truth. Kinetic modeling factors were calculated using a two-compartment linear Patlak model (FDG influx rate constant = Ki, metabolic rate = MR-FDG, distribution volume = DV-FDG) and compared to SUV using ROC analysis. Results: MR-FDG(mean) provided the best discriminatory power between benign and malignant lung lesions with an AUC of 0.887. The AUC of DV-FDG(mean) (0.818) and SUVmean (0.827) was non-significantly lower. For LNM, the AUCs for MR-FDG(mean) (0.987) and SUVmean (0.993) were comparable. Moreover, the DV-FDG(mean) in liver metastases was three times higher than in bone or lung metastases. Conclusions: Metabolic rate quantification was shown to be a reliable method to detect malignant lung tumors, LNM, and distant metastases at least as accurately as the established SUV or dual-time-point PET scans.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Whole-Body [18F]FDG-PET/MRI vs. [18F]FDG-PET/CT in Malignant Melanoma
    Dominik Berzaczy
    Barbara Fueger
    Christoph Hoeller
    Alexander R. Haug
    Anton Staudenherz
    Gundula Berzaczy
    Michael Weber
    Marius E. Mayerhoefer
    Molecular Imaging and Biology, 2020, 22 : 739 - 744
  • [2] Whole-Body [18F]FDG-PET/MRI vs. [18F]FDG-PET/CT in Malignant Melanoma
    Berzaczy, Dominik
    Fueger, Barbara
    Hoeller, Christoph
    Haug, Alexander R.
    Staudenherz, Anton
    Berzaczy, Gundula
    Weber, Michael
    Mayerhoefer, Marius E.
    MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (03) : 739 - 744
  • [3] The Impact of Whole-Body 18F FDG-PET in The Management of Patients With Small Lung Cancer
    Arslan, N.
    Budakoglu, B.
    Kuzhan, O.
    Alagoz, E.
    Emer, O.
    Ilgan, S.
    Ozguven, M. A.
    Ozet, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S296 - S296
  • [4] Metabolic aberrations in lung cancer patients as detected with a normative whole-body [18F]FDG-PET/CT database
    Gutschmayer, S.
    Ferrara, D.
    Beyer, T.
    Chen, Z.
    Taki, J.
    Kinuya, S.
    Sundar, L. K. Shiyam
    Takeda, S.
    Wakabayashi, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S504 - S505
  • [5] Ultrashort Oncologic Whole-Body [18F]FDG Patlak Imaging Using LAFOV PET
    van Sluis, Joyce
    van Snick, Johannes H.
    Glaudemans, Andor W. J. M.
    Slart, Riemer H. J. A.
    Noordzij, Walter
    Brouwers, Adrienne H.
    Dierckx, Rudi A. J. O.
    Lammertsma, Adriaan A.
    Tsoumpas, Charalampos
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (10) : 1652 - 1657
  • [6] Clinical application of whole-body [18F]-FDG-PET in malignant melanoma
    Steinert, HC
    POSITRON EMISSION TOMOGRAPHY: CRITICAL ASSESSMENT OF RECENT TRENDS, 1998, 51 : 213 - 222
  • [7] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Halbach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Jurgen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2019, 58 (02): : 68 - 76
  • [8] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Haibach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    Schoenberg, Stefan
    Vorwerk, Dierk
    Antoch, Gerald
    Anton, Frank
    Neumann, Stefan
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (04): : 289 - 297
  • [9] [18F]FDG-PET/CT in adrenal lesions: diagnostic performance in different clinical settings
    Romanisio, Martina
    Daffara, Tommaso
    Pitino, Rosa
    Ferrero, Alice
    Pizzolitto, Francesca
    Zavattaro, Marco
    Biello, Federica
    Gennari, Alessandra
    Volpe, Alessandro
    Sacchetti, Gian Mauro
    Marzullo, Paolo
    Aimaretti, Gianluca
    Prodam, Flavia
    Caputo, Marina
    ENDOCRINE, 2025, 87 (01) : 325 - 333
  • [10] Detection of cancer-associated cachexia in lung cancer patients undergoing whole-body [18F]FDG-PET/CT imaging
    Ferrara, D.
    Abenavoli, E.
    Beyer, T.
    Gruenert, S.
    Hacker, M.
    Hesse, S.
    Hofmann, L.
    Pusitz, S.
    Rullmann, M.
    Sabri, O.
    Sandoe, P.
    Sciagra, R.
    Sundar, L. K. Shiyam
    Toenjes, A.
    Wirtz, H.
    Yu, J.
    Frille, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S742 - S742