A Novel Global Calibration Approach for Multi-Viewpoint 3D Vision Measuring System

被引:0
|
作者
Sun, Pengfei [1 ]
Tan, Haishu [2 ,3 ]
Zhou, Fuqiang [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
[2] Foshan Univ, Sch Phys & Optoelect Engn, Foshan 528000, Peoples R China
[3] Ji Hua Lab, Foshan 528000, Peoples R China
关键词
Multi-viewpoint; global calibration; global binocular vision sensor; 3D vision measuring system; transformation matrix; SCANNER; RECONSTRUCTION; TRACKING;
D O I
10.1109/ACCESS.2023.3278982
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To unify the local 3D point clouds for the measured object with big size or complex structure to a global coordinate system, we usually need to adopt global calibration approach to calibrate the transformation relationship between the global binocular vision sensor (GBVS) and measuring binocular sensor (MBS) in different viewpoints in the 3D Vision Measuring System (VMS). The field of view (FOV) of the two global cameras in GBVS determines the measurement range of the 3D VMS in the global calibration process. In the traditional 3D VMS of single-station multi-viewpoint, the measurement range is limited because of the two global cameras in the GBVS are needed to have a public FOV. Then, the global calibration process is also limited. And the global calibration process is complex and easy to cause error accumulation when a laser tracker is used to replace the GBVS in the 3D VMS. In order to solve this problem, we proposed a novel global calibration approach based on multi-directional target (MDT) for a novel designed 3D VMS. It can achieve the function of global calibration for the designed 3D VMS once the MDT appears in the FOV of the global camera. Finally, we adopt two global cameras which don't need to have a public FOV to form GBVS. It can further expand the measurement range of the 3D VMS. And the global calibration efficiency can also be improved at the same time. The feasibility and effectiveness of the proposed global calibration algorithm are verified through experiments. The experimental results show that the accuracy of the proposed global calibration algorithm can reach up to 0.08 mm after optimizing. It has broad application prospects and practical theoretical research value.
引用
收藏
页码:71692 / 71704
页数:13
相关论文
共 50 条
  • [21] A novel calibration system for the plant 3d scanner
    Xu, Shengyong
    Dehua, L.
    Zhu, Li
    International Journal of Advancements in Computing Technology, 2012, 4 (10) : 45 - 53
  • [22] Multi-viewpoint Visibility Coverage Estimation for 3D Environment Perception Volumetric Representation as a Gateway to High Resolution Data
    Ososinski, Marek
    Labrosse, Frederic
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION, THEORY AND APPLICATIONS (VISAPP 2014), VOL 2, 2014, : 462 - 469
  • [23] Portable Light Pen 3D Vision Coordinate Measuring System-Probe Tip Center Calibration
    Liu, Shugui
    Zhang, Hongling
    Dong, Yinghua
    Tang, Shaliang
    Jiang, Zhenzhu
    MEASUREMENT SCIENCE REVIEW, 2013, 13 (04): : 194 - 199
  • [24] Calibration error of robotic vision system of 3D laser scanner
    Qi, Lizhe
    Tang, Qing
    Yun, Chao
    Wang, Jing
    Gan, Zhongxue
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (13): : 9 - 15
  • [25] Free and Global Pose Calibration of a Rotating Laser Monocular Vision Sensor for Robotic 3D Measurement System
    Li Lingmin
    Xi Juntong
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN2013), 2013, 8769
  • [26] Performance evaluation of a portable 3D vision coordinate measuring system
    Icasio-Hernandez, Octavio
    Gonzalez-Barbosa, Jose-Joel
    Curiel-Razo, Yajaira-Ilse
    Hurtado-Ramos, Juan B.
    AUTOMATIKA, 2017, 58 (03) : 253 - 265
  • [27] 3D Vision Based Calibration Approach for Robotic Laser Surfacing Applications
    Vanicek, Ondrej
    Chalus, Michal
    Liska, Jindrich
    2022 20TH INTERNATIONAL CONFERENCE ON MECHATRONICS - MECHATRONIKA (ME), 2022,
  • [28] Joint calibration of 2D and 3D vision integrated sensor system
    Li, Lin
    Zhang, Xu
    Tu, Dawei
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2012, 33 (11): : 2473 - 2479
  • [29] A multi-viewpoint approach for 3PLS to locate the collection center under risk environment
    Zhang yong
    Cui Xiao-yan
    Li Xu-hong
    IMECS 2007: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, VOLS I AND II, 2007, : 2285 - +
  • [30] Production of 3D consistent image representation of outdoor scenery for multimedia ambiance communication from multi-viewpoint range data measured with a 3D laser scanner
    Saito, T
    Imamura, H
    Sunaga, S
    Komatsu, T
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS V, 2002, 4661 : 70 - 81