Dimensional changes after horizontal and vertical guided bone regeneration without membrane fixation using the retentive flap technique: A 1-year retrospective study

被引:9
|
作者
Park, Jin-Young [1 ,2 ]
Chung, Hye-Min [1 ]
Strauss, Franz-Josef [3 ,4 ]
Lee, Jung-Seok [1 ,2 ,5 ]
机构
[1] Yonsei Univ, Res Inst Periodontal Regenerat, Dept Periodontol, Coll Dent, Seoul, South Korea
[2] Yonsei Univ, Innovat Res & Support Ctr Dent Sci, Dent Hosp, Seoul, South Korea
[3] Univ Zurich, Clin Reconstruct Dent, Zurich, Switzerland
[4] Univ Chile, Fac Dent, Dept Conservat Dent, Santiago, Chile
[5] Yonsei Univ, Res Inst Periodontal Regenerat, Dept Periodontol, Coll Dent, 50 Yonsei ro, Seoul 03722, South Korea
基金
新加坡国家研究基金会;
关键词
guided bone regeneration; horizontal ridge augmentation; radiographic analysis; retrospective study; vertical ridge augmentation; COMPRESSIVE FORCES; AUGMENTATION;
D O I
10.1111/cid.13237
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo evaluate the dimensional changes after horizontal and vertical guided bone regeneration (GBR) without membrane fixation using the retentive flap technique. MethodsThis study retrospectively examined two cohorts that received vertical or horizontal ridge augmentations (VA or HA groups). GBR was performed using particulate bone substitutes and resorbable collagen membranes. The augmented sites were stabilized using the retentive flap technique without any additional membrane fixation. The augmented tissue dimensions were assessed using cone-beam computed tomography at preoperative, immediately postoperative (IP), 4 months (4M), and 1 year (1Y). ResultsPostoperative vertical bone gain in 11 participants of VA group amounted to 5.96 +/- 1.88 mm at IP, which decreased to 5.53 +/- 1.62 at 4M and to 5.26 +/- 1.52 mm at 1Y (intragroup p < 0.05). The horizontal bone gain at IP in 12 participants amounted to 3.98 +/- 2.06 mm, which decreased to 3.02 +/- 2.06 at 4M and to 2.48 +/- 2.09 mm at 1Y (intragroup p < 0.05). The mean implant dehiscence defect height after 1Y was 0.19 +/- 0.50 mm in the VA group, and 0.57 +/- 0.93 mm in the HA group. ConclusionGBR without membrane fixation using the retentive flap technique seems to preserve the radiographic bone dimensions of vertically augmented sites. This technique may be less effective at preserving the width of the augmented tissue.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 21 条
  • [21] Horizontal ridge augmentation using GBR with a native collagen membrane and 1:1 ratio of particulate xenograft and autologous bone: A 3-year after final loading prospective clinical study
    Meloni, Silvio Mario
    Jovanovic, Sascha Alexander
    Urban, Istvan
    Baldoni, Edoardo
    Pisano, Milena
    Tallarico, Marco
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 669 - 677