Three-Dimensional Bioelectrical Impedance Spectroscopic Tomography for Visualization of Breast Tumor

被引:5
|
作者
Deng, Qi [1 ]
He, Jie [1 ]
Zhu, Chengjun [2 ]
Wang, Hao [3 ]
Liu, Kai [1 ]
Sun, Bo [4 ]
Yao, Jiafeng [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Peoples R China
[2] Jiangsu Prov Hosp, Dept Oncol, Nanjing 210008, Peoples R China
[3] Jinan Univ, Affiliated Hosp 1, Dept Anesthesiol, Guangzhou 215004, Peoples R China
[4] Xian Univ Technol, Sch Mech & Precis Instrument Engn, Xian 710048, Peoples R China
基金
中国国家自然科学基金;
关键词
3-D bioelectrical impedance spectroscopic tomography (3D-BIST); 3-D visualization; breast tumor; conical sensor; identification of benign and malignant; RECONSTRUCTION; ALGORITHM; EIT;
D O I
10.1109/JSEN.2023.3294185
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Visualization of breast tumors with 3-D bioelectrical impedance spectroscopic tomography (3D-BIST) is proposed to identify the position, size, benignity, and malignancy of breast tumors. First, to visualize in 3-D, a conical sensor is developed based on the actual shape of the breast. Second, to confirm the feasibility of the proposed method, finite element simulation is employed. The influence of different impedance spectroscopy data acquisition methods (0-, 1-, and 3-skip) and different classifiers [Linear-SVM, radial basis function-support vector machines (RBF-SVM), and k-nearest neighbors (KNN)] on the classification results are explored in the simulation. The simulation results show that the 3D-BIST method allows visualization of breast tumor types; the image correlation coefficient (ICC) of imaging results at each position is larger than 0.7 when the breast tumor diameter d >= 6 mm; the best acquisition method for impedance spectroscopy data is 3-skip acquisition; and the best classifier is Linear-SVM classifier. The accuracy of the verification set calculated by fivefold cross-validation achieved 93.5%. The accuracy of identifying benign and malignant breast tumors with d >= 8 mm exceeded 89.0% on the test set. Finally, the proposed method was experimentally validated by using three kinds of biological tissues in place of normal breast tissue, benign breast tumor, and malignant breast tumor. In conclusion, the 3D-BIST method enables 3-D visualization of breast tumors and identification of breast tumor types. The proposed method has the advantages of noninvasive and non-radiation, which is expected to be applied to the detection of breast tumors.
引用
收藏
页码:19598 / 19605
页数:8
相关论文
共 50 条
  • [21] Three-dimensional computed tomography for visualization of carotid bypasses in Takayasu arteritis
    Albrich, H
    Feuerbach, S
    Kasprzak, P
    Glück, T
    Schölmerich, J
    Müller-Ladner, U
    RHEUMATOLOGY, 2001, 40 (02) : 235 - 237
  • [22] Three-dimensional visualization of soil pore structure using computed tomography
    Qiaoling Han
    Xibo Zhou
    Lei Liu
    Yandong Zhao
    Yue Zhao
    Journal of Forestry Research, 2019, 30 : 1053 - 1061
  • [23] Three-dimensional visualization and metrology of nanoparticles in Inconel 718 by electron tomography
    Kulawik, Krzysztof
    Kruk, Adam
    Dubiel, Beata
    Czyrska-Filemonowicz, Aleksandra
    ELECTRON MICROSCOPY XIV, 2012, 186 : 45 - 48
  • [24] Three-dimensional electrical impedance tomography based on the complete electrode model
    Vauhkonen, PJ
    Vauhkonen, M
    Savolainen, T
    Kaipio, JP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (09) : 1150 - 1160
  • [25] Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography
    Javaherian, Ashkan
    Soleimani, Manuchehr
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 1133 - 1149
  • [26] Truncated-Newton algorithm for three-dimensional electrical impedance tomography
    Player, MA
    van Weereld, J
    Allen, AR
    Collie, DAL
    ELECTRONICS LETTERS, 1999, 35 (25) : 2189 - 2191
  • [27] A Real-Time Three-Dimensional Diffuse Optical Tomography System for Breast Tumor Detection
    Wu, Wen-Jun
    Guo, Jia-Jiun
    Fang, Wai-Chi
    2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-TAIWAN (ICCE-TW), 2018,
  • [28] Design of Three-Dimensional Electrical Impedance Tomography System for Rock Samples
    Peng, Xin
    Chun, Shaoheng
    Su, Benyu
    Chen, Rujun
    Hou, Shenglan
    Xu, Chao
    Zhang, Haojie
    APPLIED SCIENCES-BASEL, 2024, 14 (04):
  • [29] Three-dimensional nonstationary electrical impedance tomography with a single electrode layer
    Voutilainen, A.
    Lehikoinen, A.
    Vauhkonen, M.
    Kaipio, J. P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (03)
  • [30] A Post-Processing Method for Three-Dimensional Electrical Impedance Tomography
    Sébastien Martin
    Charles T. M. Choi
    Scientific Reports, 7