Development and Validation of a Strong Cation Exchange Chromatographic Column Coupled with High-Performance Liquid Chromatography Method for Meropenem and Evaluation of Its Stability in Human Plasma: Application to the Therapeutic Drug Monitoring

被引:0
|
作者
Liu, Ting [1 ,2 ]
Chen, Ling [1 ]
Yu, Panpan [3 ]
Li, Qingyu [1 ]
Lou, Jiang [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hangzhou Peoples Hosp 1, Dept Pharm, 261 Huansha Rd, Hangzhou 310006, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hangzhou Peoples Hosp 1,Dept Clin Phar, Key Lab Clin Canc Pharmacol & Toxicol Res Zhejian, 261 Huansha Rd, Hangzhou 310006, Peoples R China
[3] Zhejiang Univ, Sch Med, Affiliated Hangzhou Peoples Hosp 1, Dept Gen Surg, 261 Huansha Rd, Hangzhou 310006, Peoples R China
关键词
BETA-LACTAM ANTIBIOTICS; HUMAN SERUM; PIPERACILLIN; QUANTIFICATION; CEFTAZIDIME; CEFEPIME;
D O I
10.1093/chromsci/bmac086
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Meropenem is a wide inter-individual variability in the pharmacokinetic, and standard dosing may not be adequate in critically ill patients. Therapeutic drug monitoring is a useful tool to optimize dosing. Meropenem is the amphoteric compound with an isoelectric point of 5.15. The secondary amino group of meropenem is positively charged when pH <= 5.4, thus we attempted to separate by strong cation exchange (SCX) column using acetonitrile/25-mM potassium dihydrogen phosphate (pH 3.0; 60:40) as mobile phase, and good peak shape and effective separation obtained. Generally, meropenem were unstable in plasma. We try to investigate stability of plasma samples using the medium QC sample with or without 3-(N-morpholino) propanesulfonic acid (MOPS) as stabilizer solutions at possible conditions during handling and storage. Meropenem showed higher stability at -80 degrees C, and addition of MOPS might increase the short-term and extracted samples stability. This method is suitable for the quantification of meropenem in human plasma from 0.5 to 100 mu g/mL. The accuracy was ranged from 96.53 to 101.11% with relative standard deviation <= 4.76%. The method has been used for determined 63 critically ill patients treated with meropenem. During the first measurement, 11 patients showed trough levels below the target ranges despite standard dosing. Through continuous or prolonged infusion, 8/11 patients (72.73%) led to adequate trough levels. The described SCX-high-performance liquid chromatography method for meropenem in human plasma is a powerful tool for therapeutic drug monitoring.
引用
收藏
页码:656 / 664
页数:9
相关论文
共 50 条
  • [21] Development and Validation of a New Ultra-Performance Liquid Chromatographic Method for Vancomycin Assay in Serum and Its Application to Therapeutic Drug Monitoring
    Cao, Yuran
    Yu, Jicheng
    Chen, Yuancheng
    Zhang, Jing
    Wu, Xiaojie
    Zhang, Yingyuan
    Li, Guanghui
    THERAPEUTIC DRUG MONITORING, 2014, 36 (02) : 175 - 181
  • [23] Development and validation of a high-performance liquid chromatographic method for bioanalytical application with rimonabant
    Bhaumik, Uttam
    Ghosh, Animesh
    Chatterjee, Bappaditya
    Sengupta, Pinaki
    Darbar, Soumendra
    Roy, Bikash
    Nandi, Utpal
    Pal, Tapan K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (04) : 1009 - 1013
  • [24] Development and Validation of a High-Performance Liquid Chromatography Ultraviolet Method for Lapatinib Quantification in Human Plasma
    Escudero-Ortiz, Vanesa
    Jose Perez-Ruixo, Juan
    Valenzuela, Belen
    THERAPEUTIC DRUG MONITORING, 2013, 35 (06) : 796 - 802
  • [25] Method development and validation of a high-performance liquid chromatographic method for tramadol in human plasma using liquid-liquid extraction
    Gan, SH
    Ismail, R
    Adnan, WAW
    Wan, Z
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01): : 123 - 129
  • [26] Development and Validation of a High-Performance Thin-Layer Chromatographic Method for the Quantitative Assessment of Topiramate from Human Serum: Application in Therapeutic Drug Monitoring
    Renuka Munshi
    Namrata Gawde
    Salman Dalal
    Deepali Ganachari
    JPC – Journal of Planar Chromatography – Modern TLC, 2018, 31 : 112 - 115
  • [27] Development and Validation of a High-Performance Thin-Layer Chromatographic Method for the Quantitative Assessment of Topiramate from Human Serum: Application in Therapeutic Drug Monitoring
    Munshi, Renuka
    Gawde, Namrata
    Dalal, Salman
    Ganachari, Deepali
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (02) : 112 - 115
  • [28] DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF WARFARIN ENANTIOMERS IN HUMAN PLASMA
    WENG, ND
    LEE, JW
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (09) : 785 - 792
  • [29] Development and validation of a reliable high-performance liquid chromatographic method for determination of nodakenin in rat plasma and its application to pharmacokinetic study
    Liu, Zhigang
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (10) : 1076 - 1080
  • [30] A CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF HUMAN HEMOGLOBINS
    OU, CN
    BUFFONE, GJ
    REIMER, GL
    CLINICAL BIOCHEMISTRY, 1983, 16 (06) : 368 - 368