Optimization of structural parameters of pilot-operated control valve based on CFD and orthogonal method

被引:3
|
作者
Li, Shuxun [1 ,2 ]
Deng, Guolong [1 ,2 ]
Hu, Yinggang [1 ,2 ]
Yu, Mengyao [1 ,2 ]
Ma, Tingqian [1 ,2 ]
机构
[1] Lanzhou Univ Technol, Coll Petr & Chem Engn, Lanzhou 730050, Gansu, Peoples R China
[2] Machinery Ind Pumps & Special Valves Engn Res Ctr, Lanzhou 730050, Gansu, Peoples R China
关键词
Pilot operated control valve; Structural optimization; Orthogonal experiment; Extreme variance analysis;
D O I
10.1016/j.rineng.2024.101914
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Due to the large pressure difference between the front and back of the valve, the pilot -operated regulating valve is prone to blocking flow, and there are multiple closed cavities connected by small holes in the valve, and the flow channel is complex. If the structure design of the spool component is improper, it will seriously affect the safe and stable operation of the regulating valve. In this paper, based on the principle of multi -stage step-down and compressible medium throttling equation, the structure of the pilot valve spool assembly is preliminarily designed to prevent blocking flow. The main influencing parameters affecting the stability of the valve core of the pilot regulating valve are analyzed, and the sample space is designed by the orthogonal method. The numerical simulation analysis of the force of different test samples under different openings is carried out to study the influence of different structural parameters on the force of the valve core. Based on the trend analysis of range and influencing factors, the influence of structural parameters of regulating valve on the stability of the valve core and the optimal structural parameters of valve core assembly under this working condition are studied. ANSYS CFX software was used to calculate the flow field in the valve under the optimal working opening of different experimental samples of the control valve, and the flow field in the valve and the force of the valve core of different test samples were obtained. The analysis results show that the structural parameters affecting the stability of the spool mainly include the equivalent diameter of the main spool opening, the effective diameter of the pilot valve seat throttling, and the pilot valve damping hole. The experimental sample 16 has a large force in the whole adjustment range, floating around 12 % of 1700 N. Under the small opening of the pilot -operated regulating valve, the equivalent diameter d of the main spool opening has the greatest influence on the force of the spool. When the opening is 40 %-80 %, the structural parameter that has the greatest influence on the force of the pilot control valve spool is the main spool lifting height h. In the optimal working range of the regulating valve (30%-70%), the structural parameter that has the greatest influence on the force of the pilot regulating valve spool is the lifting height of the pilot valve spool, and its optimal size is 4.0 mm. The opening diameter of the main valve core has the second influence on the force of the valve core, and its optimal size is 2.0 mm.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Stability of pilot-operated proportional pressure reducing valve used in underwater propulsion system
    Zhou, Feng
    Gu, Lin-Yi
    Luo, Gao-Sheng
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (11): : 2047 - 2053
  • [23] Research of time lag characteristics of Pilot-operated Solenoid Valve Damper based on multi-physics field
    Wen, Hansheng
    Huang, Haibo
    Zhang, Wenjian
    Yang, Mingliang
    Ding, Weiping
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2024,
  • [24] Simulation and experiment of static and dynamic characteristics of pilot-operated proportional pressure reducing valve
    Mo, Yutong
    Zhang, Ce
    Jin, Bo
    Chen, Lei
    FLOW MEASUREMENT AND INSTRUMENTATION, 2025, 101
  • [25] CFD Simulation of Flow Field for Pilot Operated Check Valve
    Zhang, Liqiang
    Zheng, Wenjing
    Zhang, Jingfang
    Lian, Min
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 1137 - 1140
  • [26] Dynamic analysis of a pilot-operated two-stage solenoid valve used in pneumatic system
    Ye Qifang
    Chen Jiangping
    SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (05) : 794 - 816
  • [27] Modeling the Dynamic Behavior of a Pilot-Operated Solenoid Valve for an Ultra-High Pressure Vessel
    Choi, Jaeseong
    Ahn, Jung Hwan
    Kim, Hwa Young
    APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 9
  • [28] Research on flow resistance coefficient and opening force of deep diving outboard pilot-operated valve
    Liu, Shao-Gang
    Zheng, Da-Yong
    Cheng, Qian-Ju
    Binggong Xuebao/Acta Armamentarii, 2015, 36 (12): : 2363 - 2368
  • [29] Optimization of geometric parameters of hydraulic turbine runner in turbine mode based on the orthogonal test method and CFD
    Chen, Jinbao
    Zheng, Yang
    Zhang, Lihong
    He, Gang
    Zou, Yidong
    Xiao, Zhihuai
    ENERGY REPORTS, 2022, 8 : 14476 - 14487
  • [30] Design and Research for the Water Low-pressure Large-flow Pilot-operated Solenoid Valve
    Liu Lei
    Zhang Desheng
    Zhao Jiyun
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2014, 60 (10): : 665 - 674