Flow-Injection Amperometric Determination of Adrenalin, Melatonin, and Cortisol on an Electrode Modified with a Gold-Palladium Binary System and a Nafion Film

被引:0
|
作者
Shaidarova, L. G. [1 ]
Chelnokova, I. A. [1 ]
Leksina, Yu. A. [1 ]
Khairullina, D. Yu. [1 ]
Budnikov, H. C. [1 ]
机构
[1] Kazan Volga Reg Fed Univ, Butlerov Inst Chem, Kazan 420008, Tatarstan, Russia
关键词
chemically modified electrodes; gold-palladium binary system; Nafion film; screen-printed electrode; flow-injection analysis; amperometric determination of adrenaline; melatonin; cortisol; SENSOR;
D O I
10.1134/S0020168523140121
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The control of the precise concentration of steroid hormones and their synthetic analogs in biomedical objects is a relevant analytical task. A method for selective and highly sensitive simultaneous amperometric determination of adrenaline, melatonin, and cortisol with the use of a two-detector flow-injection system is developed. Screen-printed carbon electrodes (SPE) with one or two working electrodes modified with a gold-palladium binary system that exhibits catalytic activity upon electrooxidation of the organic compounds under consideration are used as detectors. The high sensitivity of determination is attributed to the catalytic properties of the metal modifier: the transition from the metal to the binary system leads to an increase in the catalytic oxidation current of hormones. The selectivity of determination of adrenaline in the presence of melatonin and cortisol is provided by the difference in the oxidation potentials of the hormones on the proposed electrode. For selective determination of melatonin and cortisol, the surface of the modified working electrode is coated with a Nafion film. The difference of potentials of the peaks of oxidation of adrenaline, melatonin, and cortisol on such an electrode is 300 mV. The proposed method is tested in the analysis of urine samples. The flow-injection scheme is supplemented with a dialyzer and a chromatographic minicolumn to eliminate the interfering effect of electrophilic compounds. The linear bilogarithmic dependence of the analytical signal on the concentration of adrenaline, melatonin, and cortisol is observed in the ranges of 5.0 x 10(-10)-5.0 x 10(-3), 5.0 x 10(-11)-5.0 x 10(-3), and 5.0 x 10(-12)-5.0 x 10(-3) mol/L, respectively. Amperometric determination of the hormones in the flow-injection system leads to an increase in the productivity of the analysis and a decrease in the consumption of the sample and makes it possible to automate the process.
引用
收藏
页码:1474 / 1481
页数:8
相关论文
共 50 条
  • [41] AMPEROMETRIC BIOSENSOR FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS USING A TYROSINASE GRAPHITE ELECTRODE IN A FLOW-INJECTION SYSTEM
    ORTEGA, F
    DOMINGUEZ, E
    JONSSONPETTERSSON, G
    GORTON, L
    JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) : 289 - 300
  • [42] PLATINUM-DISPERSED NAFION-MODIFIED GLASSY-CARBON ELECTRODE FOR THE DETERMINATION OF HYDROGEN-PEROXIDE IN A FLOW-INJECTION SYSTEM
    TAY, BT
    ANG, KP
    GUNASINGHAM, H
    ANALYST, 1988, 113 (04) : 617 - 620
  • [43] Amperometric Detection of Creatinine and Uric Acid at the Screen-Printed Electrode Modified By Gold Nanoparticles in Flow-Injection Analysis
    Shaidarova, Larisa G.
    Chelnokova, Irina A.
    II'ina, Marina A.
    Leksina, Yulia A.
    Gedmina, Anna V.
    Budnikov, Herman K.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (05): : 1629 - 1635
  • [44] AMPEROMETRIC FLOW-INJECTION BIOSENSOR SYSTEM FOR THE SIMULTANEOUS DETERMINATION OF UREA AND CREATININE
    RUI, CS
    SONOMOTO, K
    KATO, Y
    ANALYTICAL SCIENCES, 1992, 8 (06) : 845 - 850
  • [45] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [46] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold-Cobalt Binary System
    Shaidarova, L. G.
    Chelnokova, I. A.
    Gafiatova, I. A.
    Gedmina, A. V.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (03) : 372 - 377
  • [47] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [48] A poly(vinyl choloride) graphite composite electrode for flow-injection amperometric determination of antioxidants
    Luque, M
    Ríos, A
    Valcárcel, M
    ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) : 217 - 223
  • [49] Determination of thiocompounds by liquid chromatography with amperometric detection at a Nafion indium hexacyanoferrate film modified electrode
    Zhang, S
    Sun, WL
    Zhang, W
    Qi, WY
    Jin, LT
    Yamamoto, K
    Tao, SG
    Jin, JY
    ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) : 21 - 30
  • [50] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY OXIDATION AT AN IRIDIUM OXIDE ELECTRODE
    COX, JA
    LEWINSKI, K
    TALANTA, 1993, 40 (12) : 1911 - 1915