Redox Cycling Amplified Electrochemical Lateral-Flow Immunoassay: Toward Decentralized Sensitive Insulin Detection

被引:20
|
作者
Nandhakumar, Ponnusamy [1 ]
Martin, Cristina Munoz San [1 ,2 ]
Arevalo, Beatriz [1 ,2 ]
Ding, Shichao [1 ]
Lunker, Mahika [1 ]
Vargas, Eva [1 ]
Djassemi, Omeed [1 ]
Campuzano, Susana [2 ]
Wang, Joseph [1 ]
机构
[1] Univ Calif San Diego, Dept Nanoengn, La Jolla, CA 92093 USA
[2] Univ Complutense, Dept Quim Analit, E-28040 Madrid, Spain
关键词
Lateral-flow immunoassay; eLFA; immunosensor; nanocatalytic redox cycling; diabetes mellitus; insulin detection; point-of-caretesting; NANOCATALYST; AMMONIA; BORANE;
D O I
10.1021/acssensors.3c01445
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
While paper-based lateral-flow immunoassays (LFA) offer considerable promise for centralized diagnostic applications, the analytical capability of conventional LFA remains constrained due to the low sensitivity of its common optical detection strategy. To address these issues, we report a simple electrochemical LFA (eLFA) with nanocatalytic redox cycling for decentralized insulin detection. Simultaneous binding of insulin with detection antibodies and capture antibodies through the capillary flow at the LFA platform and signal amplification through the rapid nanocatalytic reduction of [Fe(CN)(6)](3-) (Fe3+) with Au nanoparticles (AuNP) and ammonia-borane (AB), coupled to electrochemical redox cycling reactions involving Fe3+, AuNP, and AB on the carbon working electrode, offer higher sensitivity than conventional colorimetric LFA and enzymatic redox cycling. The resulting integrated eLFA strip allows the detection of low insulin concentrations (LOD = 12 pM) and offers considerable promise for highly sensitive decentralized assays of different biological fluids (saliva and serum) without additional pretreatment or washing steps.
引用
收藏
页码:3892 / 3901
页数:10
相关论文
共 50 条
  • [41] Sensitive Electrochemical Detection of the Hydroxyl Radical Using Enzyme-catalyzed Redox Cycling
    Hirosuke Tatsumi
    Naoya Osaku
    Analytical Sciences, 2011, 27 : 1065 - 1067
  • [42] Detection of Paralytic Shellfish Toxins in Mussels and Oysters Using the Qualitative Neogen Lateral-Flow Immunoassay: An Interlaboratory Study
    Dorantes-Aranda, Juan Jose
    Tan, Jessica Y. C.
    Hallegraeff, Gustaaf M.
    Campbell, Katrina
    Ugalde, Sarah C.
    Harwood, D. Tim
    Bartlett, Jill K.
    Campas, Monica
    Crooks, Steven
    Gerssen, Arjen
    Harrison, Keith
    Huet, Anne-Catherine
    Jordan, Timothy B.
    Koeberl, Martina
    Monaghan, Tim
    Murray, Sam
    Nimmagadda, Rama
    Ooms, Coiunne
    Quinlan, Rae K.
    Shi, Feng
    Turner, Andrew D.
    Yaices, Betsy Jean
    Turnbull, Alison R.
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (02) : 468 - 479
  • [43] Evaluation of the QuickLab RSV test, a new rapid lateral-flow immunoassay for detection of respiratory syncytial virus antigen
    Slinger, R
    Milk, R
    Gaboury, I
    Diaz-Mitoma, F
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (08) : 3731 - 3733
  • [44] Detection of paralytic shellfish toxins in mussels and oysters using the qualitative neogen lateral-flow immunoassay: An interlaboratory study
    Dorantes-Aranda, Juan José (juanjodorantes@gmail.com), 1600, AOAC International (101):
  • [45] A Novel, Universal and Sensitive Lateral-Flow Based Method for the Detection of Multiple Bacterial Contamination in Platelet Concentrations
    Wang, Jidong
    Wang, Xiaohui
    Li, Yuan
    Yan, Shaoduo
    Zhou, Qianqian
    Gao, Bo
    Peng, Jianchun
    Du, Juan
    Fu, Qiuxia
    Jia, Shuaizheng
    Zhang, Juankun
    Zhan, Linsheng
    ANALYTICAL SCIENCES, 2012, 28 (03) : 237 - 241
  • [46] Quantum dot-based lateral-flow immunoassay for rapid detection of rhein using specific egg yolk antibodies
    Zhang, Yue
    Kong, Hui
    Liu, Xiaoman
    Cheng, Jinjun
    Zhang, Meiling
    Wang, Yongzhi
    Lu, Fang
    Qu, Huihua
    Zhao, Yan
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2018, 46 (08) : 1685 - 1693
  • [47] A Novel, Universal and Sensitive Lateral-Flow Based Method for the Detection of Multiple Bacterial Contamination in Platelet Concentrations
    Jidong Wang
    Xiaohui Wang
    Yuan Li
    Shaoduo Yan
    Qianqian Zhou
    Bo Gao
    Jianchun Peng
    Juan Du
    Qiuxia Fu
    Shuaizheng Jia
    Juankun Zhang
    Linsheng Zhan
    Analytical Sciences, 2012, 28 : 237 - 241
  • [48] A rapid monoclonal antibody-based direct immunoassay and a lateral-flow device for on-site sensitive analysis of the mycotoxin alternariol
    Addante-Moya, Luis G.
    Suay-Fuentes, Daniel
    Abad-Somovilla, Antonio
    Agullo, Consuelo
    Abad-Fuentes, Antonio
    Mercader, Josep, V
    MICROCHEMICAL JOURNAL, 2024, 199
  • [49] Quantitative and Single-step Enzyme Immunosensing Based on an Electrochemical Detection Coupled with Lateral-flow System
    Tominaga, Kohei
    Arimoto, Satoshi
    Shimono, Ken
    Yoshioka, Toshihiko
    Mizutani, Fumio
    Yasukawa, Tomoyuki
    ANALYTICAL SCIENCES, 2017, 33 (04) : 531 - 536
  • [50] Quantitative and Single-step Enzyme Immunosensing Based on an Electrochemical Detection Coupled with Lateral-flow System
    Kohei Tominaga
    Satoshi Arimoto
    Ken Shimono
    Toshihiko Yoshioka
    Fumio Mizutani
    Tomoyuki Yasukawa
    Analytical Sciences, 2017, 33 : 531 - 535