Early Warning for Abnormal Cable Forces of Cable-Stayed Bridges Considering Structural Temperature Changes

被引:18
|
作者
Li, Jin-Xin [1 ]
Yi, Ting-Hua [1 ]
Qu, Chun-Xu [1 ]
Li, Hong-Nan [1 ]
Liu, Hua [2 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian 116023, Peoples R China
[2] China Railway Bridge & Tunnel Technol Co Ltd, 8,Panneng Rd,Jiangbei New Area, Nanjing 210061, Peoples R China
基金
中国国家自然科学基金;
关键词
Cable force; Early warning; Structural temperature; Frequency-temperature relationship; Structural health monitoring; TENSION; VIBRATION; DISPLACEMENT;
D O I
10.1061/JBENF2.BEENG-5797
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The deterioration or damage of stay cables can threaten the safety of bridges. It is difficult to judge whether a stay cable is deteriorated only by the variation in cable force because cable force also varies with temperature. Therefore, an early warning method for abnormal cable forces of cable-stayed bridges considering structural temperature changes is proposed in this paper. In the proposed method, a baseline model is established to characterize the normal relationship between the healthy cable force and structural temperatures, so the abnormal cable force can be detected by inspecting the residual between the identified cable force to be detected and the cable force predicted by the baseline model. First, the frequency-temperature relationship (FTR) model obeyed by a healthy cable is established by analyzing the mechanism of cable force change caused by structural temperature changes in bridge components from the perspective of deformation coordination. Then, the prediction error is inspected by constructing a mean value control chart of the modeling error generated from the baseline FTR model. An early warning will be triggered when the prediction error exceeds the control limits. Finally, the proposed method is applied to an actual cable-stayed bridge to verify its effectiveness. The results show that the modeling and prediction capabilities of the established FTR model are satisfactory and that the abnormal changes in cable forces can be detected by the proposed early warning method with satisfactory accuracy.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Cable-Stayed Bridges.
    Ciolina, F.
    Travaux, 1975, (478): : 60 - 63
  • [32] CABLE-STAYED BRIDGES.
    Podolny Jr., Walter
    Engineering Journal, 1974, 11 (1 First Q): : 1 - 11
  • [33] CABLE-STAYED BRIDGES.
    Chalisgaonkar, Rajendra
    Indian Concrete Journal, 1986, 60 (07): : 182 - 186
  • [34] Optimization of cable pre-tension forces in long-span cable-stayed bridges considering the counterweight
    Song, Chaolin
    Xiao, Rucheng
    Sun, Bin
    ENGINEERING STRUCTURES, 2018, 172 : 919 - 928
  • [35] CONSTRUCTIBILITY OF CABLE-STAYED BRIDGES
    ROWINGS, JE
    KASPAR, SL
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT-ASCE, 1991, 117 (02): : 259 - 278
  • [36] CABLE-STAYED BRIDGES IN CRISIS
    WILSON, F
    ARCHITECTURE-THE AIA JOURNAL, 1988, 77 (12): : 111 - 114
  • [37] Aesthetics of cable-stayed bridges
    Tang, MC
    FIFTH INTERNATIONAL BRIDGE ENGINEERING CONFERENCE, VOLS 1 AND 2: BRIDGES, OTHER STRUCTURES, AND HYDRAULICS AND HYDROLOGY, 2000, 1696 : A34 - A43
  • [38] COMPUTING FOR CABLE-STAYED BRIDGES
    不详
    CIVIL ENGINEERING, 1995, 65 (08): : 14 - 18
  • [39] Structural control of bridges: Recent experiences in cable-stayed bridges
    Casas, JR
    STRUCTURAL CONTROL FOR CIVIL AND INFRASTRUCTURE ENGINEERING, 2001, : 85 - 92
  • [40] A cointegration approach for cable anomaly warning based on structural health monitoring data: An application to cable-stayed bridges
    Fan, Zi-Yuan
    Huang, Qiao
    Ren, Yuan
    Zhu, Zhi-Yuan
    Xu, Xiang
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (13) : 2789 - 2802