Early Warning for Abnormal Cable Forces of Cable-Stayed Bridges Considering Structural Temperature Changes

被引:18
|
作者
Li, Jin-Xin [1 ]
Yi, Ting-Hua [1 ]
Qu, Chun-Xu [1 ]
Li, Hong-Nan [1 ]
Liu, Hua [2 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian 116023, Peoples R China
[2] China Railway Bridge & Tunnel Technol Co Ltd, 8,Panneng Rd,Jiangbei New Area, Nanjing 210061, Peoples R China
基金
中国国家自然科学基金;
关键词
Cable force; Early warning; Structural temperature; Frequency-temperature relationship; Structural health monitoring; TENSION; VIBRATION; DISPLACEMENT;
D O I
10.1061/JBENF2.BEENG-5797
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The deterioration or damage of stay cables can threaten the safety of bridges. It is difficult to judge whether a stay cable is deteriorated only by the variation in cable force because cable force also varies with temperature. Therefore, an early warning method for abnormal cable forces of cable-stayed bridges considering structural temperature changes is proposed in this paper. In the proposed method, a baseline model is established to characterize the normal relationship between the healthy cable force and structural temperatures, so the abnormal cable force can be detected by inspecting the residual between the identified cable force to be detected and the cable force predicted by the baseline model. First, the frequency-temperature relationship (FTR) model obeyed by a healthy cable is established by analyzing the mechanism of cable force change caused by structural temperature changes in bridge components from the perspective of deformation coordination. Then, the prediction error is inspected by constructing a mean value control chart of the modeling error generated from the baseline FTR model. An early warning will be triggered when the prediction error exceeds the control limits. Finally, the proposed method is applied to an actual cable-stayed bridge to verify its effectiveness. The results show that the modeling and prediction capabilities of the established FTR model are satisfactory and that the abnormal changes in cable forces can be detected by the proposed early warning method with satisfactory accuracy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Determination of the initial cable forces for cable-stayed bridges
    Liang, Zhi-guang
    Li, Jian-zhong
    Shi, Xian-feng
    Gong Cheng Li Xue/Engineering Mechanics, 2000, 17 (03): : 121 - 126
  • [2] Structural Damage Detection of Cable-Stayed Bridges Using Changes in Cable Forces and Model Updating
    Hua, X. G.
    Ni, Y. Q.
    Chen, Z. Q.
    Ko, J. M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (09) : 1093 - 1106
  • [3] Role of Cable Forces in the Model Updating of Cable-Stayed Bridges
    Aloisio, Angelo
    Pasca, Dag Pasquale
    Rosso, Marco Martino
    Briseghella, Bruno
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (07)
  • [4] Effects of tensioning forces on the structural behavior of cable-stayed bridges
    Li Lam, Pauline Lin
    Kang, Thomas H-K
    STEEL AND COMPOSITE STRUCTURES, 2022, 43 (04): : 457 - 464
  • [5] Structural stability of cable-stayed bridges
    Kim, Seungjun
    Won, Deok Hee
    Lee, Keesei
    Kang, Young Jong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2015, 15 (03) : 743 - 760
  • [6] Structural stability of cable-stayed bridges
    Seungjun Kim
    Deok Hee Won
    Keesei Lee
    Young Jong Kang
    International Journal of Steel Structures, 2015, 15 : 743 - 760
  • [7] CABLE-STAYED BRIDGES
    GOLUB, H
    CIVIL ENGINEERING, 1971, 41 (08): : 43 - &
  • [8] Cable vibrations in cable-stayed bridges
    Virlogeux, M
    BRIDGE AERODYNAMICS, 1998, : 213 - 233
  • [9] CABLE-STAYED BRIDGES
    PODOLNY, W
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1974, 11 (01): : 1 - 11
  • [10] Multiobjective Optimization of Cable Forces and Counterweights for Universal Cable-Stayed Bridges
    Wang, Zhangming
    Zhang, Nan
    Du, Xianting
    Wang, Shilei
    Sun, Qikai
    Journal of Advanced Transportation, 2021, 2021