Pressure Drop Analysis for U-Tube Evacuated Tubular Collector

被引:1
|
作者
Alexander, Leo Daniel [1 ]
Jakhar, Sanjeev [2 ]
Dasgupta, Mani Sankar [1 ]
机构
[1] BITS Pilani, Dept Mech Engn, Pilani Campus, Pilani, Rajasthan, India
[2] Vellore Inst Technol, Sch Mech Engn, Chennai Campus, Chennai 600127, Tamil Nadu, India
关键词
PLATE SOLAR COLLECTOR; PERFORMANCE ANALYSIS; TEMPERATURE;
D O I
10.1080/01457632.2023.2289230
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is to determine the effect of water temperature and volume flow rate on the pressure drop across a U type evacuated tubular collector. The findings are expected to be useful for pump selection and to determine the pumping power required for operating an Evacuated tubular collector based solar thermal plant. A detailed mathematical model is developed, utilizing correlations found in literature. An experimental investigation is carried out on an experimental setup consisting of Evacuated tubular solar collector combined with instrumentation. The developed mathematical model was simulated, and the results were validated with the data obtained from the experimental investigation within the minimum acceptable normalized root-mean-squared error. Results showed that the pressure drop across the setup reduces as the water temperature increases. The pressure drop also exhibited a non-linear function of the volume flow rate of water and hence at higher flow rates, minor changes in volume flow rate produce a larger pressure drop across the setup.
引用
收藏
页码:1963 / 1973
页数:11
相关论文
共 50 条
  • [41] Research on the universal model of filled-type evacuated tube with U-tube in uniform boundary condition
    Liang, Ruobing
    Zhang, Jili
    Zhao, Liang
    Ma, Liangdong
    APPLIED THERMAL ENGINEERING, 2014, 63 (01) : 362 - 369
  • [42] Effects of thermal performance of enclosed-type evacuated U-tube solar collector with multi-walled carbon nanotube/water nanofluid
    Tong, Yijie
    Kim, Jinhyun
    Cho, Honghyun
    RENEWABLE ENERGY, 2015, 83 : 463 - 473
  • [43] Experimental and theoretical performance analysis of PVT-evacuated U-tube solar collectors with and without CPC integration
    Daghigh, Roonak
    Arshad, Siamand Azizi
    ENERGY, 2025, 320
  • [44] MEASUREMENT UNCERTAINTIES OF U-TUBE MANOMETERS AND PRESSURE BALANCES
    STUART, PR
    METROLOGIA, 1994, 30 (06) : 727 - 735
  • [45] Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube
    Liang, Ruobing
    Ma, Liangdong
    Zhang, Jili
    Zhao, Dan
    SOLAR ENERGY, 2011, 85 (09) : 1735 - 1744
  • [46] Structure optimization of U-tube solar collector integrated with phase change materials
    Wang, Xueyang
    Li, Dong
    Meng, Fanbin
    Wu, Yangyang
    Yang, Ruitong
    Gao, Meng
    Liu, Changyu
    APPLIED THERMAL ENGINEERING, 2025, 260
  • [47] Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area
    Wang Yong
    Guo Kai-sheng
    Tian Rong
    Han Chuan-pu
    Lai Dao-xin
    Xu Feng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 244 - 248
  • [48] U-TUBE NEPHROSTOMY
    WEYRAUCH, HM
    ROUS, SN
    JOURNAL OF UROLOGY, 1967, 97 (02): : 225 - &
  • [49] A NEW EVACUATED CPC COLLECTOR TUBE
    OGALLAGHER, JJ
    SNAIL, K
    WINSTON, R
    PEEK, C
    GARRISON, JD
    SOLAR ENERGY, 1982, 29 (06) : 575 - 577
  • [50] Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area
    王勇
    郭凯生
    田荣
    韩传璞
    赖道新
    徐峰
    Journal of Central South University, 2009, 16 (S1) : 244 - 248