Rational design of donor-acceptor fluorescent probe for the ratiometric point-of-care testing of human serum albumin

被引:12
|
作者
Chen, Zihao [1 ]
Xu, Zhongyong [1 ]
Qin, Tianyi [2 ]
Wang, Dagang [1 ]
Zhang, Shiwei [3 ]
Lv, Taoyuze [4 ]
Wang, Lei [1 ]
Chen, Xiaoqiang [1 ]
Liu, Bin [1 ]
Peng, Xiaojun [1 ]
机构
[1] Shenzhen Univ, Coll Mat Sci & Engn, State Key Lab Fine Chem, Shenzhen 518060, Peoples R China
[2] Hainan Univ, Sch Biomed Engn, Key Lab Biomed Engn Hainan Prov, Haikou 570228, Peoples R China
[3] Shenzhen Acad Metrol & Qual Inspect, Shenzhen, Peoples R China
[4] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
基金
中国国家自然科学基金;
关键词
Fluorescent probes; Structural engineering; Ratiometric; Point-of-care; Human serum albumin; SENSOR PROTEINS; NANOPARTICLES; STATES;
D O I
10.1016/j.snb.2023.134687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human serum albumin (HSA) is an important biomarker for chronic kidney disease, cardiovascular disease, and liver disease, yet its measurement is subject to the routine clinical laboratories. Pioneering studies have demonstrated that few of the ratiometric fluorescent probes enable the point-of-care (POC) testing of HSA with the aid of affordable domestic apparatuses. Still, the lack of choices of fluorophores restricts the development of such assay. In the present work, we propose two design strategies on the typical donor-acceptor fluorescent probe via the structural engineering. The results suggest that replacement of the dimethylamino group in probe by the weaker electron donating thiophene group can effectively tune the fluorescence response to HSA from off-on to ratiometric, ideally suiting for the POC application. The screened fluorescent probe is capable of detecting HSA with the features of fast response (< 10 s), stable output, high sensitivity (limit of detection = 54 nM), tunable detection range, and great anti-interference. Moreover, the ratiometric fluorescence response to HSA can be recorded and analyzed by the portable miniaturized paper-based or 3D-printed devices at the point of need. The success of structural engineering in the present study provides an efficient way to rationally regulate the fluorescence response mode of the donor-acceptor probes.
引用
收藏
页数:9
相关论文
共 26 条
  • [21] GNP/CNT nanocomposite coated screen-printed electrode for point-of-care testing of dopamine in human serum
    Zhu, Wen
    Zhu, Aiping
    Shu, Yun
    PROGRESS IN ORGANIC COATINGS, 2022, 170
  • [22] RhIr@MoS2 nanohybrids based disposable microsensor for the point-of-care testing of NADH in real human serum
    Ji, Dongqing
    Ying, Zi
    Zhang, Yuan
    Chen, Wei
    Janyasupab, Metini
    Gao, Xinghua
    Feng, Lingyan
    Wen, Weijia
    CHINESE CHEMICAL LETTERS, 2020, 31 (08) : 2115 - 2118
  • [23] RhIr@MoS2 nanohybrids based disposable microsensor for the point-of-care testing of NADH in real human serum
    Dongqing Ji
    Zi Ying
    Yuan Zhang
    Wei Chen
    Metini Janyasupab
    Xinghua Gao
    Lingyan Feng
    Weijia Wen
    ChineseChemicalLetters, 2020, 31 (08) : 2115 - 2118
  • [24] An environment-sensitive fluorescent probe for quantification of human serum albumin: Design, sensing mechanism, and its application in clinical diagnosis of hypoalbuminemia
    Luo, Zijie
    Liu, Bin
    Zhu, Kangning
    Huang, Yingying
    Pan, Chengjun
    Wang, Bingfeng
    Wang, Lei
    DYES AND PIGMENTS, 2018, 152 : 60 - 66
  • [25] Peptide modified paper based impedimetric immunoassay with nanocomposite electrodes as a point-of-care testing of Alpha-fetoprotein in human serum
    Moazeni, Maryam
    Karimzadeh, Fathallah
    Kermanpur, Ahmad
    BIOSENSORS & BIOELECTRONICS, 2018, 117 : 748 - 757
  • [26] An enhanced fluorescent probe through the strategy of using MgWO4 nanosheets to enhance terbium ion luminescence for highly sensitive and point-of-care visual quantitative testing of ciprofloxacin integrated with a low-cost smartphone-based platform
    Zhang, Jingfei
    Zhang, Yu
    Shi, Guoyue
    ANALYST, 2021, 146 (24) : 7710 - 7719