Rational design of donor-acceptor fluorescent probe for the ratiometric point-of-care testing of human serum albumin

被引:12
|
作者
Chen, Zihao [1 ]
Xu, Zhongyong [1 ]
Qin, Tianyi [2 ]
Wang, Dagang [1 ]
Zhang, Shiwei [3 ]
Lv, Taoyuze [4 ]
Wang, Lei [1 ]
Chen, Xiaoqiang [1 ]
Liu, Bin [1 ]
Peng, Xiaojun [1 ]
机构
[1] Shenzhen Univ, Coll Mat Sci & Engn, State Key Lab Fine Chem, Shenzhen 518060, Peoples R China
[2] Hainan Univ, Sch Biomed Engn, Key Lab Biomed Engn Hainan Prov, Haikou 570228, Peoples R China
[3] Shenzhen Acad Metrol & Qual Inspect, Shenzhen, Peoples R China
[4] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
基金
中国国家自然科学基金;
关键词
Fluorescent probes; Structural engineering; Ratiometric; Point-of-care; Human serum albumin; SENSOR PROTEINS; NANOPARTICLES; STATES;
D O I
10.1016/j.snb.2023.134687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human serum albumin (HSA) is an important biomarker for chronic kidney disease, cardiovascular disease, and liver disease, yet its measurement is subject to the routine clinical laboratories. Pioneering studies have demonstrated that few of the ratiometric fluorescent probes enable the point-of-care (POC) testing of HSA with the aid of affordable domestic apparatuses. Still, the lack of choices of fluorophores restricts the development of such assay. In the present work, we propose two design strategies on the typical donor-acceptor fluorescent probe via the structural engineering. The results suggest that replacement of the dimethylamino group in probe by the weaker electron donating thiophene group can effectively tune the fluorescence response to HSA from off-on to ratiometric, ideally suiting for the POC application. The screened fluorescent probe is capable of detecting HSA with the features of fast response (< 10 s), stable output, high sensitivity (limit of detection = 54 nM), tunable detection range, and great anti-interference. Moreover, the ratiometric fluorescence response to HSA can be recorded and analyzed by the portable miniaturized paper-based or 3D-printed devices at the point of need. The success of structural engineering in the present study provides an efficient way to rationally regulate the fluorescence response mode of the donor-acceptor probes.
引用
收藏
页数:9
相关论文
共 26 条
  • [1] A supramolecular ratiometric fluorescent probe for the detection of human serum albumin
    Liu, Xue
    Qi, Shuang
    Mao, Jingyao
    Zhang, Yuteng
    Dong, Bin
    Song, Bo
    Ji, Lingling
    DYES AND PIGMENTS, 2024, 224
  • [2] Paper-Based Ratiometric Fluorescence Analytical Devices towards Point-of-Care Testing of Human Serum Albumin
    Luo, Zijie
    Lv, Taoyuze
    Zhu, Kangning
    Li, Yi
    Wang, Lei
    Gooding, J. Justin
    Liu, Guozhen
    Liu, Bin
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (08) : 3131 - 3136
  • [3] Rational design of a FA1-targeting anti-interference fluorescent probe for the point-of-care testing of albuminuria
    Deng, Weihua
    Xu, Zhongyong
    Li, Na
    Lv, Taoyuze
    Wang, Lei
    Li, Mingle
    Chen, Xiaoqiang
    Liu, Bin
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 261
  • [4] A smartphone integrated ratiometric fluorescent sensor for point-of-care testing of fluoride ions
    Zhang, Liule
    Gao, Xia
    Chen, Xiying
    Zhao, Minyang
    Wu, Haotian
    Liu, Yaqing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (13) : 3999 - 4009
  • [5] A smartphone integrated ratiometric fluorescent sensor for point-of-care testing of fluoride ions
    Liule Zhang
    Xia Gao
    Xiying Chen
    Minyang Zhao
    Haotian Wu
    Yaqing Liu
    Analytical and Bioanalytical Chemistry, 2022, 414 : 3999 - 4009
  • [6] Ratiometric Fluorescent Lateral Flow Immunoassay for Point-of-Care Testing of Acute Myocardial Infarction
    Wang, Jing
    Jiang, Chenxing
    Jin, Jiening
    Huang, Liang
    Yu, Wenbo
    Su, Bin
    Hu, Jun
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2021, 60 (23) : 13042 - 13049
  • [7] Toward the point-of-care testing of alkaline phosphatase in human serum
    Lucio-Rivera, Zachary
    Gudgel, Robert
    Gorski, Waldemar
    BIOSENSORS & BIOELECTRONICS, 2024, 265
  • [8] Rapid Point-of-Care Quantification of Human Serum Albumin in Urine Based on Ratiometric Fluorescence Signaling Driven by Intramolecular H-Bonding
    Sarkar, Sourav
    Shil, Anushree
    Jung, Yun Lim
    Singha, Subhankar
    Ahn, Kyo Han
    ACS SENSORS, 2022, 7 (12): : 3790 - 3799
  • [9] Rational design of MoS2 QDs and Eu3+ as a ratiometric fluorescent probe for point-of-care visual quantitative detection of tetracycline via smartphone-based portable platform
    Zhang, Jingfei
    Shi, Guoyue
    ANALYTICA CHIMICA ACTA, 2022, 1198
  • [10] Sensitive and accurate monitoring of urinary albumin and point-of-care testing using a fluorescent probe with anti-interference capacity against exogenous drugs
    Lu, Cuizhen
    Xu, Liang
    Jiang, Yu
    Liao, Caiqiang
    Li, Yixin
    Tang, Yinghao
    Xu, Zhongyong
    Du, Xinfeng
    Lv, Taoyuze
    Wang, Yalong
    Qin, Tianyi
    Liu, Bin
    Zhu, Mingqiang
    TALANTA, 2024, 279