Postfire Performance of Thread-Anchored Blind-Bolted Connection

被引:3
|
作者
You, Yang [1 ]
Li, Yang [2 ]
Lin, Chunjin [3 ]
Wang, Peijun [4 ]
Ye, Jihong [5 ]
Jiang, Jian [5 ]
机构
[1] Shandong Jiaotong Univ, Sch Transportat & Civil Engn, Jinan 250357, Peoples R China
[2] Univ Manchester, Dept Sci & Engn, Booth St East, Manchester M13, England
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Peoples R China
[4] Shandong Univ, Sch Civil Engn, Jinan 250061, Peoples R China
[5] China Univ Min & Technol, Sch Mech & Civil Engn, Xuzhou 221116, Peoples R China
基金
中国国家自然科学基金;
关键词
Thread-anchored blind bolt (TBB); Postfire; Internal strengthening component (ISC); Square hollow section column connection (SHSCC); Tensile behavior; BEHAVIOR; COLUMNS;
D O I
10.1061/JSENDH.STENG-12687
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thread-anchored blind bolt (TBB) is anchored by a threaded bolt hole instead of a nut. It can only be mounted from one side, providing an alternative method to build the square hollow section column connection (SHSCC). A study on the change of mechanical behavior of a structural component after exposure to fire is the key to its reuse or repair after a fire. The tensile performance of TBB bolted SHSCC after a fire, and the effect of the internal strengthening component (ISC) was studied by experiments. The full-period method was adopted in the test to consider the influence of the load and temperature on the postfire behavior of the TBB bolted SHSCC. Two failure modes of the TBB bolted SHSCC were observed in the test, and the column wall thickness decided the failure mode. Increased load or temperature could cause the connection to fail previously in a fire but not change the failure mode. The TBB bolted SHSCC could recover most of its resistance after cooling down. Comparative tests were also conducted to assess the difference between the SHSCC bolted by TBB and standard bolt (SB). TBB and SB connections with the same configuration showed the same failure mode under the same condition. The TBB and SB connections demonstrated similar postfire performance when the column wall thickness was large. However, the SB connections showed a much better safety reserve than TBB ones when the column wall thickness was limited. The ISC improved the performance of TBB bolted SHSCC significantly when the column wall thickness was limited. The TBB bolted SHSCC strengthened by ISC could also be comparable to the TBB bolted ones.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Moment-Rotation Model for Blind-Bolted Flush End-Plate Connections in Composite Frame Structures
    Ataei, Abdolreza
    Bradford, Mark A.
    Valipour, Hamid R.
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (09)
  • [42] Push-out behaviour of demountable injected vs. blind-bolted connectors in FRP decks
    Csillag, Fruzsina
    Pavlovic, Marko
    COMPOSITE STRUCTURES, 2021, 270
  • [43] Seismic design and pseudo-dynamic tests of blind-bolted CFT frames with buckling-restrained braces
    Li, Beibei
    Wang, Jingfeng
    Baniotopoulos, Charalampos C.
    Yang, Jian
    Hu, Yu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
  • [44] Fire and post-fire performance of blind-bolted concrete-filled steel tubular joints with restrained steel beams: Experiment and simulation
    Song, Tian-Yi
    Zhu, Di
    Zhou, Hongyuan
    Xiang, Kai
    Chen, Zheng
    THIN-WALLED STRUCTURES, 2023, 193
  • [45] THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF BOLTED JOINT WITH HELICAL THREAD CONNECTION
    Bommisetty, Kondaiah
    Narayanan, Kumar
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2014, 2014,
  • [46] Static behavior of TOBs bolted endplate connection to strengthened HSST with fixed thread length
    Cai, Min
    Liu, Le
    Li, Shuo
    Cheng, Tianxi
    Jin, Xiao
    Hao, Yuchang
    Liu, Mei
    Wang, Peijun
    Liu, Fangzhou
    STRUCTURES, 2023, 54 : 478 - 498
  • [47] Seismic tests and numerical investigation of blind-bolted moment CFST frames infilled with thin-walled SPSWs
    Zhang, Zengde
    Wang, Jingfeng
    Li, Beibei
    Zhao, Chunfeng
    THIN-WALLED STRUCTURES, 2019, 134 : 347 - 362
  • [48] Post-fire seismic performance of concrete-filled steel tubular column to steel beam joints with blind-bolted connections: Experiment and simulation
    Han, Lin-Hai
    Song, Tian-Yi
    Li, Shuai
    ENGINEERING STRUCTURES, 2023, 283
  • [49] Experimental study on torque coefficient and on shear performance of a novel blind bolted connection with high-strength bolts
    Fan J.-W.
    Yang L.
    Ban H.-Y.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (01): : 119 - 128
  • [50] Hysteretic performance of a new blind bolted connection to concrete filled columns under cyclic loading: An experimental investigation
    Tizani, Walid
    Wang, Zhi Yu
    Hajirasouliha, Iman
    ENGINEERING STRUCTURES, 2013, 46 : 535 - 546