Postfire Performance of Thread-Anchored Blind-Bolted Connection

被引:3
|
作者
You, Yang [1 ]
Li, Yang [2 ]
Lin, Chunjin [3 ]
Wang, Peijun [4 ]
Ye, Jihong [5 ]
Jiang, Jian [5 ]
机构
[1] Shandong Jiaotong Univ, Sch Transportat & Civil Engn, Jinan 250357, Peoples R China
[2] Univ Manchester, Dept Sci & Engn, Booth St East, Manchester M13, England
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Peoples R China
[4] Shandong Univ, Sch Civil Engn, Jinan 250061, Peoples R China
[5] China Univ Min & Technol, Sch Mech & Civil Engn, Xuzhou 221116, Peoples R China
基金
中国国家自然科学基金;
关键词
Thread-anchored blind bolt (TBB); Postfire; Internal strengthening component (ISC); Square hollow section column connection (SHSCC); Tensile behavior; BEHAVIOR; COLUMNS;
D O I
10.1061/JSENDH.STENG-12687
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thread-anchored blind bolt (TBB) is anchored by a threaded bolt hole instead of a nut. It can only be mounted from one side, providing an alternative method to build the square hollow section column connection (SHSCC). A study on the change of mechanical behavior of a structural component after exposure to fire is the key to its reuse or repair after a fire. The tensile performance of TBB bolted SHSCC after a fire, and the effect of the internal strengthening component (ISC) was studied by experiments. The full-period method was adopted in the test to consider the influence of the load and temperature on the postfire behavior of the TBB bolted SHSCC. Two failure modes of the TBB bolted SHSCC were observed in the test, and the column wall thickness decided the failure mode. Increased load or temperature could cause the connection to fail previously in a fire but not change the failure mode. The TBB bolted SHSCC could recover most of its resistance after cooling down. Comparative tests were also conducted to assess the difference between the SHSCC bolted by TBB and standard bolt (SB). TBB and SB connections with the same configuration showed the same failure mode under the same condition. The TBB and SB connections demonstrated similar postfire performance when the column wall thickness was large. However, the SB connections showed a much better safety reserve than TBB ones when the column wall thickness was limited. The ISC improved the performance of TBB bolted SHSCC significantly when the column wall thickness was limited. The TBB bolted SHSCC strengthened by ISC could also be comparable to the TBB bolted ones.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Fire behavior of novel Thread-anchored One-side bolted connection with internal component
    You, Yang
    Gu, Hangping
    Wang, Qishuai
    Cheng, Tianxi
    Wang, Peijun
    Zhang, Wenchao
    Liu, Fangzhou
    Zhai, Guangjun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [2] Fire behavior of novel Thread-anchored One-side bolted connection with internal component
    You, Yang
    Gu, Hangping
    Wang, Qishuai
    Cheng, Tianxi
    Wang, Peijun
    Zhang, Wenchao
    Liu, Fangzhou
    Zhai, Guangjun
    Journal of Constructional Steel Research, 2022, 194
  • [3] Experimental performance of single blind-bolted CFST column connection under predominant shear loading
    Debnath, Partha Pratim
    Chan, Tak-Ming
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [4] Column face bending in anchored blind-bolted connections to concrete filled hollow sections
    Mahmood, Mohammed
    Tizani, Walid
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 224
  • [5] Structural Performance of a New Blind-Bolted Frame Modular Beam-Column Connection under Lateral Loading
    Cho, Bong-Ho
    Lee, Jae-Sub
    Kim, Hongjin
    Kim, Dae-Jin
    APPLIED SCIENCES-BASEL, 2019, 9 (09):
  • [6] Cyclic Behavior of Anchored Blind-Bolted Extended End-Plate Joints to CFST Columns
    Wang, Yihuan
    Wang, Zhan
    Pan, Jianrong
    Wang, Peng
    Qin, JianGui
    Chen, Shizhe
    APPLIED SCIENCES-BASEL, 2020, 10 (03):
  • [7] Fire performance of blind-bolted connections to concrete filled tubular columns in tension
    Pascual, Ana M.
    Romero, Manuel L.
    Tizani, Walid
    ENGINEERING STRUCTURES, 2015, 96 : 111 - 125
  • [8] Post-fire behavior of square hollow section column connections using thread-anchored blind bolts
    You, Yang
    Li, Yang
    Lin, Chunjin
    Wang, Peijun
    Jiang, Jian
    Ye, Jihong
    STRUCTURES, 2024, 59
  • [9] Numerical performance of blind-bolted demountable square CFST K-joints
    Jin, Dengyiding
    Hou, Chao
    Shen, Luming
    Han, Lin-Hai
    JOURNAL OF BUILDING ENGINEERING, 2021, 33
  • [10] Anchored blind bolted composite connection to a concrete filled steel tubular column
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Mirza, Olivia
    STEEL AND COMPOSITE STRUCTURES, 2017, 23 (01): : 115 - 130