Predicting vasospasm risk using first presentation aneurysmal subarachnoid hemorrhage volume: A semi-automated CT image segmentation analysis using ITK-SNAP

被引:6
|
作者
Street, James S. [1 ]
Pandit, Anand S. [2 ,3 ]
Toma, Ahmed K. [2 ]
机构
[1] UCL, Inst Neurol, Dept Clin & Expt Epilepsy, London, England
[2] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, Queen Sq, London, England
[3] UCL, Inst Neurol, High Dimens Neurol, London, England
来源
PLOS ONE | 2023年 / 18卷 / 06期
关键词
DELAYED CEREBRAL-ISCHEMIA; INTRAVENTRICULAR HEMORRHAGE; TRANSCRANIAL DOPPLER; SYMPTOMATIC VASOSPASM; BLOOD; QUANTIFICATION; COMPLICATIONS; ASSOCIATION; VALIDATION; ALGORITHM;
D O I
10.1371/journal.pone.0286485
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeCerebral vasospasm following aneurysmal subarachnoid hemorrhage (aSAH) is a significant complication associated with poor neurological outcomes. We present a novel, semi-automated pipeline, implemented in the open-source medical imaging analysis software ITK-SNAP, to segment subarachnoid blood volume from initial CT head (CTH) scans and use this to predict future radiological vasospasm. Methods42 patients were admitted between February 2020 and December 2021 to our tertiary neurosciences center, and whose initial referral CTH scan was used for this retrospective cohort study. Blood load was segmented using a semi-automated random forest classifier and active contour evolution implemented in ITK-SNAP. Clinical data were extracted from electronic healthcare records in order to fit models aimed at predicting radiological vasospasm risk. ResultsSemi-automated segmentations demonstrated excellent agreement with manual, expert-derived volumes (mean Dice coefficient = 0.92). Total normalized blood volume, extracted from CTH images at first presentation, was significantly associated with greater odds of later radiological vasospasm, increasing by approximately 7% for each additional cm(3) of blood (OR = 1.069, 95% CI: 1.021-1.120; p < .005). Greater blood volume was also significantly associated with vasospasm of a higher Lindegaard ratio, of longer duration, and a greater number of discrete episodes. Total blood volume predicted radiological vasospasm with a greater accuracy as compared to the modified Fisher scale (AUC = 0.86 vs 0.70), and was of independent predictive value. ConclusionSemi-automated methods provide a plausible pipeline for the segmentation of blood from CT head images in aSAH, and total blood volume is a robust, extendable predictor of radiological vasospasm, outperforming the modified Fisher scale. Greater subarachnoid blood volume significantly increases the odds of subsequent vasospasm, its time course and its severity.
引用
收藏
页数:19
相关论文
共 8 条
  • [1] Machine Learning Using Presentation CT Perfusion Imaging for Predicting Clinical Outcomes in Patients With Aneurysmal Subarachnoid Hemorrhage
    Yin, Pengzhan
    Wang, Jiaqi
    Zhang, Chao
    Yuan, Jinlong
    Ye, Mingquan
    Zhou, Yunfeng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (06) : 817 - 835
  • [2] Quantitative Segmentation Analysis of the Radiological Changes by Using ITK-SNAP: Risk Assessment of the Severity and Recurrence of Medication-related Osteonecrosis of the Jaw
    Zhou, Yu-qiong
    Son, Gee-hun
    Shi, Yue-qi
    Yu, Ye-jia
    Li, Meng-yu
    Zhang, Qin
    Zou, Duo-hong
    Zhang, Zhi-yuan
    Yang, Chi
    Wang, Shao-yi
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2021, 18 (10): : 2209 - 2216
  • [3] Analysis of risk factors correlated with angiographic vasospasm in patients with aneurysmal subarachnoid hemorrhage using explainable predictive modeling
    Kim, Kwang Hyeon
    Koo, Hae-Won
    Lee, Byung-Jou
    Sohn, Moon-Jun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 91 : 334 - 342
  • [4] 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
    Woehl, Rebecca
    Maier, Johannes
    Gehmert, Sebastian
    Palm, Christoph
    Riebschlaeger, Birgit
    Nerlich, Michael
    Huber, Michaela
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [5] 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
    Rebecca Woehl
    Johannes Maier
    Sebastian Gehmert
    Christoph Palm
    Birgit Riebschlaeger
    Michael Nerlich
    Michaela Huber
    BMC Musculoskeletal Disorders, 19
  • [6] Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method
    Bae, K. T.
    Shim, H.
    Tao, C.
    Chang, S.
    Wang, J. H.
    Boudreau, R.
    Kwoh, C. K.
    OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (12) : 1589 - 1597
  • [7] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Hideo Arai
    Masateru Kawakubo
    Ko Abe
    Hikaru Hatashima
    Kenichi Sanui
    Hiroshi Nishimura
    Toshiaki Kadokami
    The International Journal of Cardiovascular Imaging, 2020, 36 : 111 - 119
  • [8] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Arai, Hideo
    Kawakubo, Masateru
    Abe, Ko
    Hatashima, Hikaru
    Sanui, Kenichi
    Nishimura, Hiroshi
    Kadokami, Toshiaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (01): : 111 - 119