Management of Nonunion of Distal Tibial Periarticular Fractures Using Ilizarov External Fixator

被引:0
|
作者
Zayda, Ahmed [1 ]
Badr, Ismail Tawfeek [1 ]
机构
[1] Menoufia Univ, Fac Med, Dept Orthopaed Surg, Shibin Al Kawm 32511, Menoufia, Egypt
来源
TECHNIQUES IN FOOT AND ANKLE SURGERY | 2024年 / 23卷 / 01期
关键词
Ilizarov fixator; periarticular; distal tibia; nonunion; ankle deformity; AOFAS; PILON FRACTURES; METAPHYSEAL NONUNIONS; INFECTED NONUNION; BLADE PLATE; OUTCOMES; RECONSTRUCTION; PSEUDARTHROSIS; HINDFOOT;
D O I
10.1097/BTF.0000000000000398
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Nonunion of the periarticular distal tibial fractures is a challenging issue with limited options for treatment. The study aims to evaluate the outcomes of treatment of non-united periarticular distal tibial fractures using Ilizarov external fixation. A retrospective study included 16 patients with distal tibial fracture nonunion treated with Ilizarov fixator from 2014 to 2019 with a minimum 1-year follow-up after frame removal. Fibular plating was done in 8 cases and supplementary interfragmentary screws at the nonunion site in 5 cases. Primary or delayed bone graft was used in 11 patients. The ASAMI protocol was used to assess the bone and functional results. The American Orthopaedic Foot and Ankle Society (AOFAS) scale was used to assess the functional outcomes. Study included 9 males and 7 females, mean age of 47.4 +/- 14.1 years. 15 cases had previous surgeries for nonunion. 7 had active infection. duration of nonunion was 24.1 +/- 13.2 months. Mean duration of fixation was 5.7 +/- 1.0 months. Mean follow-up was 21.8 +/- 8.5 months. Mean AOFAS score improved from 52.4 +/- 3.7 preoperatively to 85.4 +/- 9.8 at the latest follow-up (P<0.001). Finally, the infection was resolved, and union was achieved in all patients. Bone results were excellent in 3 cases and good in 13, whereas functional results were excellent in 6 cases, good in 8, fair in 1, and poor in 1. Ilizarov fixator is a reliable option for treating nonunion in the periarticular distal tibial fractures. It provides secure fixation for short distal fragments, especially with history of infection, those with bad skin conditions, previous failed internal fixation, and osteopenic bone.
引用
收藏
页码:12 / 20
页数:9
相关论文
共 50 条
  • [31] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237
  • [32] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Yu Zhou
    Yanbiao Wang
    Lifeng Liu
    Zhenyu Zhou
    Xuecheng Cao
    International Orthopaedics, 2015, 39 : 2227 - 2237
  • [33] Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation
    H. El Barbary
    H. Abdel Ghani
    H. Misbah
    K. Salem
    International Orthopaedics, 2005, 29 : 182 - 185
  • [34] Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation
    El Barbary, H
    Ghani, HA
    Misbah, H
    Salem, K
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (03) : 182 - 185
  • [35] Limited open reduction and Ilizarov external fixation in the treatment of distal tibial fractures
    Leung, F
    Kwok, HY
    Pun, TS
    Chow, SP
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (03): : 278 - 283
  • [36] Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator
    Hayoung Kim
    Sang Ki Lee
    Kap Jung Kim
    Jae Hoon Ahn
    Won Sik Choy
    Yong In Kim
    Jea Yun Koo
    International Orthopaedics, 2009, 33 : 835 - 841
  • [37] Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator
    Kim, Hayoung
    Lee, Sang Ki
    Kim, Kap Jung
    Ahn, Jae Hoon
    Choy, Won Sik
    Kim, Yong In
    Koo, Jea Yun
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 835 - 841
  • [38] Treatment of a Periarticular Tibial Fracture in a Foal with a Hybrid External Fixator
    De Godoy, Roberta Ferro
    Filgueiras, Richard R.
    Gontijo, Lilian A.
    Bezerra Ximenes, Fabio Henrique
    De Gouvea, Liana Villela
    Pereira, Cristiane Da Silva
    Almeida, Ricardo M.
    Leite, Ceci Ribeiro
    Neto, Antonio Raphael T.
    Junqueira Borges, Jose Renato
    VETERINARY SURGERY, 2009, 38 (05) : 650 - 653
  • [39] Adjunctive hyperbaric oxygen therapy in the treatment of atrophic tibial nonunion with Ilizarov external fixator: a radiographic and scintigraphic study in rabbits
    Kurklu, Mustafa
    Yurttas, Yuksel
    Kose, Ozkan
    Demiralp, Bahtiyar
    Yuksel, Halil Yalcin
    Komurcu, Mahmut
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (02) : 126 - 131
  • [40] Treatment of infectious nonunion of tibia in elderly patient using Ilizarov external fixator - A case report
    Takagi, Y.
    Yamada, H.
    Kanazawa, Y.
    Nasu, W.
    Toratani, T.
    Kagechika, K.
    Tsuchiya, H.
    PROCEEDINGS OF THE 1ST CONFERENCE OF THE ASIAN OCEANIA SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE, 2008, : 197 - +