Laboratory full-scale test on the bond property of GFRP anchor to concrete

被引:7
|
作者
Sun, Gan [1 ]
Yan, Nan [1 ]
Bai, Xiaoyu [1 ]
Liu, Junwei [1 ]
Hou, Dongshuai [1 ]
Sang, Songkui [1 ]
Zhang, Mingyi [1 ]
Wang, Pan [1 ]
Jing, Desheng [1 ]
机构
[1] Qingdao Univ Technol, Sch Civil Engn, 777 Jialingjiang Rd, Qingdao 266520, Shandong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Model test; Ultimate bearing capacity; Mechanical anchorage; REINFORCED POLYMER BARS; STRENGTH DEGRADATION; SLIP; PERFORMANCE; DURABILITY; LENGTH; REBARS; MODEL;
D O I
10.1016/j.conbuildmat.2023.132216
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glass fiber reinforced polymer (GFRP) bolt, which has excellent mechanical properties and corrosion resistance, is gradually replacing metal bolt in rock and soil anchoring, compared with traditional reinforced bolts and other composite materials with high cost. In the current study, the influence of anchorage length and anchorage mode on the bonding property of bolt and concrete was investigated, and the stress mechanism of glass fiber bolt was analyzed based on the tensile test of a full-size laboratory sample. The results show that the failure modes of GFRP anti-floating anchor were pull-out failure and fracture failure, the ultimate bearing capacity of mechanical anchorage was noted as 1.08-1.24 times that of linear anchorage. Under the same anchorage method, with the increase of anchorage length, the relative displacement and the proportion of load bearing in the easing section of the bolt load-displacement curve decreased; thus, the load-displacement curve of the anchor in the form of mechanical anchorage was smoother. With the increase of load, the main load bearing mode of the bolt-concrete interface changed from the interface friction force and chemical adhesive force to the mechanical bite force, and then the interface concrete was broken, and the concrete no-acting zone was transformed into the acting zone until the bolt was damaged. Anchor had a maximum anchorage length beyond which the bearing capacity of the anchors increased minimally. Comparing the calculation formulas of anchor length under different national standards, it was suggested to use Chinese or European standards to calculate anchor length.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Full-Scale Field Test of Wake Steering
    Fleming, Paul
    Annoni, Jennifer
    Scholbrock, Andrew
    Quon, Eliot
    Dana, Scott
    Schreck, Scott
    Raach, Steffen
    Haizmann, Florian
    Schlipf, David
    WAKE CONFERENCE 2017, 2017, 854
  • [42] Lessons from a full-scale fire test
    Izzuddin, BA
    Moore, DB
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2002, 152 (04) : 319 - 329
  • [43] FULL-SCALE TEST OF A COMPOSITE TRUSS.
    Bjorhovde, Reidar
    Structural Engineering Report, 1981, (97):
  • [44] Full-scale cold bending demonstration test
    Gergess, Antoine N.
    Sen, Rajan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (10) : 1295 - 1304
  • [45] SMALL-ANCHOR TESTS TO PREDICT FULL-SCALE HOLDING POWER
    COLE, MW
    BECK, RW
    SOCIETY OF PETROLEUM ENGINEERS JOURNAL, 1970, 10 (02): : 127 - &
  • [46] FULL-SCALE TESTING OF A PRESTRESSED CONCRETE SEGMENTAL BRIDGE
    MCCLURE, RM
    WEST, HH
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1984, 11 (03) : 505 - 515
  • [47] STRUCTURAL RESPONSE OF FULL-SCALE CONCRETE BOX CULVERT
    ABDELKARIM, AM
    TADROS, MK
    BENAK, JV
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (11): : 3238 - 3254
  • [48] Repair and performance of a full-scale pretensioned concrete girder
    Saiidi, MS
    Labia, Y
    Douglas, B
    PCI JOURNAL, 2000, 45 (02): : 96 - +
  • [49] Full-scale testing of prestressed concrete bridge girders
    Ahlborn, TM
    Shield, CK
    French, CW
    EXPERIMENTAL TECHNIQUES, 1997, 21 (01) : 33 - 35
  • [50] Full-scale testing of prestressed concrete bridge girders
    T. M. Ahlborn
    C. K. Shield
    C. W. French
    Experimental Techniques, 1997, 21 : 33 - 35