A Miniature Forward-Looking Phased-Array Transducer for Interventional Biopsy Guidance

被引:5
|
作者
Lv, Jiabing [1 ,2 ]
Wang, Ninghao [1 ,2 ]
Zhu, Xinle [1 ,2 ]
Li, Zhangjian [3 ]
Shen, Zhitian [3 ]
Cui, Yaoyao [1 ,2 ]
Jian, Xiaohua [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Hefei 230052, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Ultrasound Dept, Suzhou 215163, Peoples R China
[3] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Ultrasound Dept ment, Suzhou 215163, Peoples R China
基金
中国国家自然科学基金;
关键词
Transducers; Ultrasonic imaging; Probes; Magnetic resonance imaging; Needles; Biopsy; Sensors; Forward-looking; high-frequency; interventional biopsy guidance; miniature; phased-array transducer; ULTRASOUND-GUIDED INTERVENTIONS; RESOLUTION; MRI; CT;
D O I
10.1109/JSEN.2023.3246094
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ultrasound-guided interventional biopsy is becoming an increasingly popular and valuable tool in the clinic. Conventionally, low-frequency (1-5 MHz) ultrasound probes are employed on the patient's body surface for guiding interventional procedures, leading to low imaging resolution and low puncture accuracy. Several efforts have been made to achieve precise punctures, such as inserting a miniaturized high-frequency phased-array transducer into the patient's body. However, the interventional devices (introducer biopsy needles) are all separate from those ultrasound probes, which will cause additional damage and operation complexity. Therefore, in this work, a miniature higher frequency phased-array probe integrated with a 0.4 mm intervention working channel is developed, which had 48 array elements and an outer diameter of only 3 mm. The center frequency and -6 dB bandwidth of this probe are measured as 26.2 MHz and 59.6%, respectively. For evaluating its guiding performance, the wire-phantom, ex vivo tissue, and tissue-mimicking phantom experiments were tested. According to the experiments, the axial imaging resolution and lateral resolution can be calculated as 88 and 278 mu m at a distance of 2 mm far away, respectively, and the effective detecting depth is 12 mm. All these results show that our proposed ultrasound transducer and method can adapt to the works in high-precision interventional guidance.
引用
收藏
页码:6509 / 6516
页数:8
相关论文
共 50 条
  • [41] Building localization from forward-looking infrared images for UAV guidance
    Qin Y.
    Cao Zh.
    Li H.
    Wang X.
    Zhuo W.
    Gyroscopy Navig., 2013, 4 (188-197): : 188 - 197
  • [42] SAW RF SPECTRUM ANALYZER CHANNELIZER USING A FOCUSING PHASED-ARRAY TRANSDUCER
    BROOKS, RE
    WILCOX, JZ
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 93 - 93
  • [43] Acousto-Optic Transfer Function Control by a Phased-Array Piezoelectric Transducer
    Yushkov, Konstantin B.
    Chizhikov, Alexander I.
    Molchanov, Vladimir Ya.
    PHOTONICS, 2023, 10 (10)
  • [44] Phased-Array Transducer for Intracardiac Echocardiography Based on 1-3 Piezocomposite
    Han, Zhile
    Wang, Ninghao
    Li, Zhangjian
    Zhu, Xinle
    Chen, Youwei
    Jian, Xiaohua
    Cui, Yaoyao
    FRONTIERS IN MATERIALS, 2021, 8
  • [45] A preliminary round-robin study of ultrasonic phased-array transducer variability
    Friedl, JH
    Roberts, RA
    Margetan, F
    Umbach, JA
    Degtyar, A
    Hassan, W
    Vensel, F
    Thompson, RB
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 892 - 899
  • [46] The Sparse Sampling and Compressed Sensing Imaging for Forward-looking Array SAR
    Liu, Xiangyang
    Zhang, Jianhang
    Li, Xiaoting
    Zhao, Haiyan
    Wang, Jing
    2016 CIE INTERNATIONAL CONFERENCE ON RADAR (RADAR), 2016,
  • [47] Structural optimization design on the arc receiver array of forward-looking sonar
    Zhao, Dongdong
    Li, Fuzeng
    Chen, Peng
    Mao, Weibo
    Guo, Xinxin
    Shengxue Xuebao/Acta Acustica, 2022, 47 (03): : 329 - 338
  • [48] Non flouroscopic guidance of interventional procedures using a phased-array imaging and hemodynamic ultrasound catheter (AcuNav): In vivo experimental studies
    Li, P
    Dairywala, I
    Liu, Z
    Mathew, B
    Bowie, D
    Vannan, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 382A - 382A
  • [49] A method of antenna design and analysis for forward-looking array SAR system
    Liu Xiang-Yang
    Meng Jin
    Liu Xu-Gang
    Niu De-Zhi
    Zhao Hai-Yan
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2018, 37 (01) : 66 - 71
  • [50] Structural optimization design on the arc receiver array of forward-looking sonar
    ZHAO Dongdong
    LI Fuzeng
    CHEN Peng
    MAO Weibo
    GUO Xinxin
    ChineseJournalofAcoustics, 2023, 42 (01) : 40 - 57