A Miniature Forward-Looking Phased-Array Transducer for Interventional Biopsy Guidance

被引:5
|
作者
Lv, Jiabing [1 ,2 ]
Wang, Ninghao [1 ,2 ]
Zhu, Xinle [1 ,2 ]
Li, Zhangjian [3 ]
Shen, Zhitian [3 ]
Cui, Yaoyao [1 ,2 ]
Jian, Xiaohua [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Hefei 230052, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Ultrasound Dept, Suzhou 215163, Peoples R China
[3] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Ultrasound Dept ment, Suzhou 215163, Peoples R China
基金
中国国家自然科学基金;
关键词
Transducers; Ultrasonic imaging; Probes; Magnetic resonance imaging; Needles; Biopsy; Sensors; Forward-looking; high-frequency; interventional biopsy guidance; miniature; phased-array transducer; ULTRASOUND-GUIDED INTERVENTIONS; RESOLUTION; MRI; CT;
D O I
10.1109/JSEN.2023.3246094
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ultrasound-guided interventional biopsy is becoming an increasingly popular and valuable tool in the clinic. Conventionally, low-frequency (1-5 MHz) ultrasound probes are employed on the patient's body surface for guiding interventional procedures, leading to low imaging resolution and low puncture accuracy. Several efforts have been made to achieve precise punctures, such as inserting a miniaturized high-frequency phased-array transducer into the patient's body. However, the interventional devices (introducer biopsy needles) are all separate from those ultrasound probes, which will cause additional damage and operation complexity. Therefore, in this work, a miniature higher frequency phased-array probe integrated with a 0.4 mm intervention working channel is developed, which had 48 array elements and an outer diameter of only 3 mm. The center frequency and -6 dB bandwidth of this probe are measured as 26.2 MHz and 59.6%, respectively. For evaluating its guiding performance, the wire-phantom, ex vivo tissue, and tissue-mimicking phantom experiments were tested. According to the experiments, the axial imaging resolution and lateral resolution can be calculated as 88 and 278 mu m at a distance of 2 mm far away, respectively, and the effective detecting depth is 12 mm. All these results show that our proposed ultrasound transducer and method can adapt to the works in high-precision interventional guidance.
引用
收藏
页码:6509 / 6516
页数:8
相关论文
共 50 条
  • [1] Development of a High Frequency Forward-looking Phased-array Transducer in Guiding Interventional Procedures
    Lv, Jiabing
    Wang, Ninghao
    Gao, Feng
    Shen, Zhitian
    Cui, Yaoyao
    Li, Hongwei
    Jian, Xiaohua
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [2] Forward-looking 30-MHz phased-array transducer for peripheral intravascular imaging
    Cabrera-Munoz, Nestor E.
    Eliahoo, Payam
    Wodnicki, Robert
    Jung, Hayong
    Chiu, Chi Tat
    Williams, Jay A.
    Kim, Hyung Ham
    Zhou, Qifa
    Shung, K. Kirk
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 280 : 145 - 163
  • [3] MINIATURE PHASED-ARRAY TRANSDUCER MODELING AND DESIGN
    SZABO, TL
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 207 - 207
  • [4] Design of ultrasonic array transducer for downhole forward-looking imaging
    Meng, Weidong
    Yan, Shouguo
    Huang, Juan
    Zhang, Bixing
    Shengxue Xuebao/Acta Acustica, 2025, 50 (01): : 138 - 148
  • [5] Phased array radar forward-looking imaging based on correlated imaging
    Ruan F.
    Guo L.
    Li Y.
    Xu R.
    Ruan, Feng, 1600, Chinese Institute of Electronics (43): : 2457 - 2462
  • [6] FORWARD-LOOKING IMAGING OF SCANNING PHASED ARRAY RADAR BASED ON THE COMPRESSED SENSING
    Wen, Xiaoyang
    Kuang, Gangyao
    Hu, Jiemin
    Zhan, Ronghui
    Zhang, Jun
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2013, 143 : 575 - 604
  • [7] Forward-looking imaging based on real beam scanning phased array radars
    Wen, Xiaoyang
    Kuang, Gangyao
    Hu, Jiemin
    Zhan, Ronghui
    Zhang, Jun
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2014, 35 (07): : 1977 - 1991
  • [8] Intracardiac echocardiography in the interventional catheterization laboratory: Preliminary experience with a novel, phased-array transducer
    Bruce, CJ
    Nishimura, RA
    Rihal, CS
    Hagler, DJ
    Higano, ST
    Seward, JB
    Holmes, DR
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (05): : 635 - +
  • [9] Phased-array antenna has piezoelectric transducer
    不详
    MICROWAVES & RF, 2001, 40 (12) : 56 - 56
  • [10] ANNULAR PHASED-ARRAY - A NEW TRANSDUCER TECHNOLOGY
    SCHWAIGHOFER, B
    FRUHWALD, F
    SEIDL, G
    STIGLBAUER, R
    ULTRASCHALL IN DER MEDIZIN, 1986, 7 (04): : 189 - 192